If you must install a radiator at home, you must find a reliable radiator installation company, otherwise it is very easy to have that or that problem after installing the radiator, for example, there will be customers who report that water seepage occurs at the connection of the pipeline, or water seepage occurs when the radiator has a small hole. If the radiator in your home leaks a small hole, what should you do, let's follow Jin Jin to find out.
1. What should I do if the radiator leaks a small hole?
1. If the small hole of the radiator is relatively small, we can find a nail to nail it to the top of the radiator pipeline, as long as the small hole can be plugged, most of them are not easy to have the problem of water seepage.
2. In addition, if the radiator has a small eye, it can also be repaired with the tire of the bicycle, and it is immediately fixed with super glue at the sand hole of the radiator, and at the same time, it is also necessary to tie it with stainless steel wire firmly, which can reasonably deal with the problem of water seepage, and because the eye is smaller, the working pressure will be relatively small, and the choice of this method can be reasonable waterproof and plugging.
3. If the trachoma is slightly larger, we must also choose a super strong coagulant, which can repair the trachoma or crevices, this kind of blocking agent has a certain degree of cohesiveness, and can cover the trachoma, and then deal with the problem of water seepage.
4. If the water seepage situation is more serious, you can only ask technical professional staff to come to the door for maintenance, and if necessary, it is very likely that the radiator pipe must be replaced.
2. What should I do if the radiator at home seeps water?
1. First of all, you must turn off the water control gate valve, and under normal circumstances, if it is some annular gate valve, you must tighten it in the clockwise direction until the screw does not move the cut-off, and then turn off the radiator at home.
2. Next, you have to find a way to plug part of the seepage, you can use a cotton towel to coil the pipe, and then prepare a sink in advance to let the water flow to the basin, otherwise the road surface at home will be wet.
3. Contact the maintenance personnel below and ask them to come to solve the difficulties.
-
1. There is generally a detergent (descaler) at home, repeatedly brush or dip the detergent into the plug, and then try to unscrew the plug after a while;
2. Soak the plug wire with gasoline on the plug wire, and then pour it after a while, and try again after repeating it several times;
3. Brush or dip it in banana water at the silk mouth, repeat it many times and try again;
4. If it really doesn't work, try to use a hair dryer to evenly heat the plug around the wire mouth and the wire mouth, and then try to unscrew it when you are fully heated and sure that the heat has been conducted into the inner wire mouth;
-
You can find a heating company to repair it, or you can find a worker to repair it yourself.
-
If the radiator at home leaks, it will affect daily use. What should I do if the radiator leaks at home? PChouse will take you to find out.
Step 1: Plug the leaking area.
In the event of a radiator leakage accident, if the leakage is not serious, gently wrap the tube with a towel or rag, leave a section and put it in the basin, so that the water can flow naturally into the basin to avoid damage to the floor, electrical appliances and other items at home.
Step 2: Close the control valve at the leaking area.
Carefully inspect the leaking part of the radiator, find the control valve of the leaking part, and then rotate the leaking part valve clockwise until it cannot be twisted, so that the radiator of the group is closed. Here we would like to remind everyone that after closing the valve, the water leakage has not been alleviated, which means that the valve may have been selected wrongly, or it has failed to age.
Step 3: Quickly close the entrance valve.
At present, almost every household in the central heating area has an entrance valve that allows them to control their own heating system individually. If the heating leakage is serious or even bursting, the user should close the entrance valve as soon as possible. Generally, the valves at home have a switch direction, and the valve can be closed according to the prompts.
Step 4: Do a good job of emergency heating.
If you still want to stay in this room, you must take corresponding heating emergency measures, such as electric radiators, air conditioning, adding clothes or bedding, etc., to avoid catching a cold.
Step 5: Contact a professional maintenance person.
After the above process operation is completed, the user should immediately call the heating maintenance center, or contact the brand manufacturer who purchased the radiator, and come to the door to deal with the water leakage problem as soon as possible.
-
Emergency treatment methods after radiator leakage: 1. When encountering radiator leakage at home, users first need to carefully find the leakage part. 2. Because the heating system is divided into two ways, there are at least 2 control valves.
3. Rotate the determined control valve clockwise until it cannot be stopped. 4. After closing the valve, investigate whether the leakage situation has improved, if not, it means that the valve has failed or the wrong valve has been selected.
Hello, happy to answer your questions. There are many ways to deal with this. If it's just a small area of water seepage, you can buy some glue. This glass glue, gluing these is particularly good. The effect is very noticeable. >>>More
Radiator leakage generally do not repair, replace the best, because the radiator is a high pressure, high temperature resistant equipment, manual maintenance of this equipment will leave potential safety hazards, you only repair the surface leakage, the internal reason you can not see, in case you are not at home leakage will cause you greater economic losses.
First, the first operation should be gradually injected hot water to start the geothermal heat, in the hot water, first half open the water distributor water supply loop valve, the hot water temperature gradually increased into the pipeline circulation. Check whether there is any abnormality in the interface of the water separator, and open the valves of each branch of the water separator one by one. If there is leakage of water separators and pipes, the main valve for water supply and return should be closed in time, and the developer or geothermal company should be contacted in time. >>>More
If the heating pipe is broken and leaking, turn off the main valve immediately, and then find a plumber to fix it as soon as possible, and then you can continue to open the valve and continue to heat.
Causes and solutions: This situation generally rarely happens, if there is, it may be that the user's heating pipe valve is not opened, resulting in the radiator hot water can not be circulated. At this time, you only need to contact the property or heating company to open the valve.