According to your gas stove, the socket of the range hood should be about 2.3 meters above the ground, and the hole should be in the outer wall, and the pipe can be added if it is too short.
-
It can be determined according to the position of your smoke machine, and the length of the smoke pipe cannot exceed two meters anyway.
-
Staying above the suspended ceiling, the current smoke pipe goes from the suspended ceiling.
-
Commercial houses have special flues, please check them.
-
There are 2 exhaust outlets in the kitchen, one of which is a range hood, which is used for exhaust fumes. The other, generally directly to the outdoors, is used for gas exhaust emissions from water heaters.
-
It should be a flue, please take a look at the picture above.
-
Summary. If there is really no other way, the exhaust hole of the range hood can go through the kitchen flue.
If there is really no other way, the exhaust hole of the range hood can go through the kitchen flue.
This is the worst way to go.
If you can design not to go, try not to go.
In this way, it is relatively smooth, and the exhaust to the public flue will be subject to a certain resistance, and the residents in the building are using the range hood here to observe and wait for the problem of difficulty in exhausting the smoke.
If the wind pressure of the range hood is not greater than the pressure of the public flue, the oil smoke will run along the range hood flue to our kitchen, and at the same time, we should pay attention to the early installation of the check valve, we must ensure that the check valve can be opened and closed normally, and the stool stall will also cause the backflow of oil smoke.
-
Summary. Hello, yes. Kitchen smoke exhaust is generally reserved at the flue exhaust hole, if you want to change the position, you should re-punch the hole, the original reserved hole is blocked.
Hello, yes. Shouhong kitchen smoke exhaust in the flue fiber place is generally reserved for the smoke exhaust hole, if you want to change the position, you should re-punch the hole, the original reserved hole to block.
My house is a cauldron flue.
I want to take the hood out of the kitchen cauldron flue.
It is a rural cauldron smoke pipe.
Easy to pour smoke. Got it.
If you want to go, I have an exhaust fan, the location of the installation, etc., it is best to contact a professional and install it.
That is to say, if you burn a cauldron, you will pour smoke?
That's right. Isn't there a baffle when the hood doesn't work?
Some. The baffle of the range hood can be opened, generally a snap-on installation method, if it needs to be opened, press and hold the panel with both hands and pull it down.
If they both work at the same time, it is easy to smoke cigarettes.
How much does it cost to punch the flue of the range hood.
100 pieces is about the same. See how big. About 100-200 volts, according to the thickness of the wall hall, the location, size, and height of Kong Qingjide are different, ** changes, and there is no specific charging standard.
-
Smoke exhaust pipes are generally 15 cm and 18 cm in diameter, but now the popular ones in the market are 15 cm. It is very convenient to leave the hole small and then expand, and it is not difficult to change it to small if it is left large, but it is easy to return to the smell if the seal is not good. As long as the kitchen roof is not hoisted, it can be changed later.
The smoke exhaust pipe of a gas water heater is generally 6 cm in diameter. The above dimensions are net sizes. The product will have a manual.
Method: Insert one end of the smoke exhaust pipe into the notch between the inner and outer rings of the air outlet of the check valve, and tighten it with screws. The other end extends directly into the outside through the reserved hole.
If the smoke exhaust pipe is connected to the public flue, it must be connected with the public flue anti-return smoke check valve and sealed well. If the smoke is exhausted outside the wall, it is recommended to install blinds on the outside of the smoke exhaust pipe to avoid backfilling.
Precautions: 1. If the smoke is discharged to the common flue, do not insert the smoke exhaust pipe too deep to increase the smoke exhaust resistance. If it leads to the outside, be sure to extend the smoke exhaust pipe mouth 3 cm.
2. The smoke exhaust pipe should not be too long, preferably not more than 2 meters, and try to minimize bending, avoid multiple 90-degree bending, otherwise it will affect the effect of oil smoke.
3. The smoke exhaust pipe stretches out outdoors or leads into the public cold air flue, and the interface should be tight, and the exhaust gas is not allowed to be discharged into the hot flue.
-
Answer: The side range hood flue is on the ceiling or under the ceiling, generally the newly renovated ones are installed on the ceiling, because they are installed on the ceiling, the smoke exhaust pipe is hidden on the ceiling, and it is invisible from the outside, which is very beautiful. The smoke exhaust pipe can also be placed on the ceiling, and it will not sag in the middle or be fixed by another shelf, which is easy to install. Placed on the ceiling can also reduce the smoke exhaust noise of the smoke exhaust pipe.
The flue of the building is fixed in place, and the recommended height of the range hood is about 1.6 meters close to the position of the wall flue.
-
The range hood comes with an exhaust pipe, and the installer pays you to get it.
After being connected by the range hood, it is directly connected to the flue mouth through the kitchen ceiling (the developer has a reserved wood that needs to be opened).
-
This is basically a question with no standard answer.
First of all, look at your purchase agreement to see if there are any restrictions that cannot be changed. If there is, whether it is true that the kitchen exhaust hole also belongs to the scope that cannot be changed.
Secondly, see if there is a decoration deposit, now many houses are deposited, and when the decoration is over, the money can only be returned after acceptance. As far as I know, most deposits are non-refundable.
The most fundamental thing is what you use to open the hole, whether it will affect the seismic performance of the house, whether it will break the steel bar or something.
Finally, look at the wind direction, it is best not to change to the dominant wind direction, in that way, there will often be a little bit of reverse wind in the exhaust pipe, which will also affect the work of the range hood.
Let's make a decision after comprehensive judgment.
Kitchen range hood equipment cleaning operation long-term use of range hood, flue is not often cleaned, there will be a lot of oil stains left on the hood and flue surface, after a long time will form grease, simple cleaning is not able to deal with, which will affect the use of range hood, flue, so that the smoke flow is not easy to eliminate. The kitchen is an important area for safety and fire prevention, and it is particularly important to clean kitchen facilities and equipment, especially range hoods. Range hood cleaning method: >>>More
Many people have different needs for range hoods, some need side suction, and some need top suction. It is best to choose a first-line range hood brand, so that the quality and after-sales of the range hood are guaranteed! There are related brand introductions for range hoods. >>>More
It is better to use a top-suction range hood in the kitchen, and you can choose the brand Fotile, which will be of better quality.
Kitchen fume cleaning is a relatively comprehensive job, if there is too much kitchen fume, it is very dangerous. Therefore, it must be cleaned regularly, if it is a large kitchen, it is necessary to clean the oil stain of the fume pipe, after cleaning the oil stain, the cleaning agent should also be sprayed with cleaning agent with the conditions of spraying cleaning agent, and you must pay attention to safety, spraying for a while to wait for the dirt to be cleaned, rinse with clean water, and be sure to rinse it clean. to ensure that the equipment is not ready for damage. >>>More
Don't put plants in the kitchen, there will be bugs.