This is a common question because the resistance at one end of the floor heating is high, and the resistance at which end of the radiator is low. So the water flows through the radiators with low resistance and flows away. This will lead to a situation where the floor heating is not hot.
All you need to do is add a thermostat valve to that set of small radiators. Floor heating (low temperature and low pressure) and radiators (high temperature and high pressure) are two different heating methods, so it is not recommended to mix them. If the set temperature of the mixed wall-hung boiler should not be too high, the temperature should be controlled below 60.
Otherwise, it may accelerate the aging of the geothermal pipes and cause water leakage failures.
-
Mul. 1. If the bathroom radiator is not hot, it may be the phenomenon of "gas blockage" in the home heating, and then you need to vent the radiator, the specific method is as follows: 牋.
1. Exhaust the radiator first, and stop deflation when you find that the radiator blockage has improved. Mul.
2. If the effect is not good after exhausting, then the next step is to turn off the water inlet valve and release water at the return position of the last group of radiators until it is finished. Mul.
3. After the water is discharged, turn off the return valve, and then open the inlet valve to the maximum and deflate it again. Mul.
4. When there is water flowing out, open the return valve. Mul.
Second, if the inspection of the radiator is not the phenomenon of "gas blockage", then it is necessary to check whether the water inlet and outlet mode of the heater is reversed, because when the radiator is installed in and out of the water in and out of the reverse, it will also cause the phenomenon that the radiator is not hot. Mul.
Third, the last bathroom radiator is not hot, it may also be caused by pipeline blockage, because the bathroom pipe is easy to age and rust, at this time, the dirty object flows with the water, and just stays in the bathroom radiator, resulting in the bathroom radiator is not hot. The specific treatment method is that the user needs to clean the whole group of radiators to solve the problem, if you have experience, you can deal with it yourself, if you are inexperienced, it is best to ask a professional master to help.
-
1. The floor heating filter is blocked, if the main water supply bar is not hot, it may be because the water quality is too poor or too dirty, so that the filter is blocked, which affects the normal circulation of the system.
Solution: Close the water supply valve and return valve first, then open the filter to clean the filter inside, and finally install it back. If the operation is not good and you are afraid of damaging the filter, you can find a professional to clean it.
2. The floor is too high, the pipeline pressure is not enough, the floor is too high or is at the end of the water supply in the community, the pressure in the pipeline is not large enough, and the expected effect cannot be achieved, and the speed of water flow will be directly reduced, which will lead to insufficient hot water in the pipeline.
Solution: You can first find the property and heating company to solve the problem, if you can't solve it, you can consider buying a circulating pump to improve the circulation of hot water, which will generally be improved.
3. The circuit is uneven, if it is in the same area, the heating effect of other users is very good, but the effect is very poor, it may be that the floor heating construction circuit is uneven.
Solution: Use the small valve on the water separator to mediate the circulation of each circuit, so that it can circulate evenly and achieve a good heating effect.
-
The floor heating inlet and return pipes are hot, but the house is not hot, indicating that there is a problem with the circulation of floor heating under the ground or the external insulation effect is too poor.
There are 3 factors that make it not hot in the house:
1. The indoor temperature is not up to standard, so that the indoor temperature cannot reach the winter temperature of 16-22 degrees.
2. The temperature of the inlet and outlet water is low, which cannot meet the rising heating temperature.
3. The circulation of the floor heating pipe is not smooth, and the indoor temperature cannot be heated quickly.
Solution: 1 The room is poorly insulated. The glass is single-layer glass, and the wall has no thermal insulation effect. This can only be passively protected, if the windows are not opened often, the balcony is added with glass doors.
2 The temperature of the underfloor warm water inlet is low. Under normal circumstances, the floor temperature is required to be below 60 degrees, and if the temperature is 30 to 40 degrees, then it is impossible for the temperature of the room to rise. So raise the temperature of the water supply.
3. The circulation speed of the floor heating pipe is slow or the flow rate is small. Generally speaking, such problems are caused by the blockage of the floor heating pipes, cleaning the floor heating pipes and increasing the circulation pump can allow the heat to dissipate heat quickly in the circulation of the floor heating pipes.
-
If the radiator is installed in and out of the water in and out of the water in the opposite way, the radiator will not be hot, and it may also be the heating at home"Air blockage", you need to vent the radiator. A few groups of radiators are hot and some groups are not hot, and it is also possible that the pipes are blocked.
If the pipe is blocked, it is likely that the pipe is aging and rusty, and the dirty object flows with the water, just staying in the radiator in the bathroom, resulting in the toilet radiator not being hot. At this time, the user needs to clean the entire set of radiators to solve the problem.
-
There are many reasons why the gas sheet is not hot, such as your installation location, the system is made by them, the size of the radiator, the water output of the boiler, whether the radiator pipeline is blocked, the water pressure problem, whether the pipeline is relatively small, resulting in a small water flow, etc., it is recommended that you find an installation company to see, it should be solved.
-
This is a difficult problem to deal with.
The reason may be that the pipes in the master bedroom and bathroom have been altered (too many elbows or the pipe diameter has become thinner) during the renovation, resulting in too much backwater resistance in these two places, so that the water flow has taken a shortcut.
The only solution is to restore the way it was. Or add a circulating pump to your plumbing (which is forbidden by heating companies).
-
This is a difficult question to solve. du
Your home must be divided into households for heating, and the radiators are installed in parallel, the reason may be that the pipes between the master bedroom and the bathroom have been altered during the renovation (too many elbows or the pipe diameter has become thinner), resulting in excessive backwater resistance in these two places, which makes the water flow take a shortcut.
The only solution is to restore the way it was. Or add a circulating pump to your plumbing (which is forbidden by heating companies).
This is a difficult question to solve. du
Your home must be divided into households for heating, and the radiators are installed in parallel, the reason may be that the pipes between the master bedroom and the bathroom have been altered during the renovation (too many elbows or the pipe diameter has become thinner), resulting in excessive backwater resistance in these two places, which makes the water flow take a shortcut.
The only solution is to restore the way it was. Or add a circulating pump to your plumbing (which is forbidden by heating companies).
-
Look**, this installation is very unprofessional, you should first determine whether the radiator is hot or not? If the radiator is hot, the water temperature is fine. But the radiator should have a throttling valve, if all the hot water is not circulated back from the radiator, the floor heating resistance is large, the water cannot be circulated, and it is definitely not hot.
-
Hello, there are several cases:
1.The pressure in the pipeline is not enough, and you need to buy a pressurized pump.
2.The water cycle route is too long, this is a problem of installation, and it is necessary to find a worker to solve it3. There is air pressure in the pipe, close the return valve all the way, and then manually open the exhaust valve of the floor heating all the way for exhaust, there may be water flowing out during the exhaust process, you can find a container to catch the overflowing water, and wait for the air in the floor heating pipe to be completely discharged, and then see the effect.
4.The filter is too dirty and clogged, just clean it up.
-
The inlet and return valves should be opened, only open the inlet water, the water cannot circulate, and the heat exchange cannot be formed, and the room will definitely not be hot.
-
Your room should be gas self-heating, it looks like your water inlet valve is open, the water outlet valve is not open, and the water is not circulating so that it is not hot. If it still doesn't work, drain each group of floor heating pipes separately and deflate the air. If it doesn't work, it's best to find a professional master to repair it.
It's not a big problem.
If you install floor heating, the water is usually flushed, and there is a slight temperature under your feet, but the overall space is not hot, which is quite wasteful. >>>More
The convection-based copper-aluminum composite radiator has become one of the hot products in the cold winter because of its outstanding anti-corrosion performance, high calorific price ratio, high value retention rate and beautiful appearance. >>>More
Radiators can be roughly divided into cast iron radiators, copper-aluminum composite radiators, steel radiators, copper radiators, aluminum-plastic radiators, and other categories in terms of material. >>>More
The sewer pipe on the top of the bathroom belongs to the upstairs owner, who uses the real estate of the downstairs owner for drainage, and it is clear that the upstairs owner should be responsible. According to Article 92 of the Property Law of the People's Republic of China, if the owner of immovable property uses adjacent immovable property for the purpose of using water, drainage, passage, laying pipelines, etc., it shall try to avoid causing damage to the adjacent immovable property owner; Where damage is caused, compensation shall be given. >>>More
First, the radiator has not been cleaned for many years, and there is too much scale. >>>More