Humidifier plugged in and not responding?

Updated on number 2024-07-10
9 answers
  1. Anonymous users2024-02-12

    1. Humidifier.

    If the control switch of the humidifier does not respond, or the controller is broken, it will cause the humidifier to be unable to receive the control instructions, and the control switch or controller needs to be replaced to solve the problem.

    2. If the control switch or controller of the humidifier is in a normal state, then check whether the control line is loose and whether there are any traces of burning, if the control line is loose, you need to turn off the power of the humidifier and then tighten the control line. If there are burn marks on the control cable, replace the control wire.

    3. If the humidifier is not used for a long time, or is not used frequently, the accessories inside the humidifier may be aging, poor contact, etc., which is the same as the computer will not be stuck for a long time and the car needs to be run in for a period of time if it is not used for a long time, in this case, the humidifier needs to be used for a period of time.

  2. Anonymous users2024-02-11

    Here's mine, I hope it can help you. Install all accessories before using the Shulax Aromatherapy Humidifier, fill the water tank with an appropriate amount of water, close the top cover and turn on the power, and the humidifier enters standby mode. The magnetic levitation top water filling technology is adopted, which can separate water and electricity, pull and move the water tank without leakage, click the power button to turn on, the default mid-range fog, and the current humidity will be displayed in the middle.

    Cleaning method of ultrasonic humidifier: 1. Cut off the power supply and pour out the residual water: Before cleaning the ultrasonic humidifier, you should first cut off the power supply and pour the residual water in the machine.

    2. Clean appearance: Usually use clean water and soft cloth to clean the appearance of the humidifier, and the Schulox transpiration humidifier adopts a detachable power cord design, which is easy to plug and unplug, easy to store and move. There is no restriction on the use of space, you can move it freely, and the humidifier is not heavy, so even girls can easily move it.

    Connect the power cord to the power connector on the back of the humidifier, and when the power is turned on, you will hear a "drop" sound and enter the standby state. Press the power button to turn on the humidifier. Connect the power cord to the power connector on the back of the humidifier and hear it when it is plugged in"Drops", enter the standby state.

    Press the power button to turn on the humidifier. The upper and lower layers of the box are tightly wrapped in white foam, the body of the humidifier is fixed in the center, and the outer layer is wrapped with scotch tape to protect it from damage during transportation. In addition to the main body of the SCHULOX Transpiration Humidifier, it also comes with an instruction manual for the product, a remote control for operation, and a cleaning brush.

    The power cord and tank filter are securely stored in the carton of the tank. The power cord of the Schulox Transpiration Pure Humidifier is located at the bottom of the rear of the machine, and the attached power cord is white, which is the same color as the host, and this power cord is common to kitchen appliances such as household rice cookers.

  3. Anonymous users2024-02-10

    There are five reasons why:

    1. If the humidifier control switch does not respond, the controller is broken or the control signal is wrong.

    2. The control switch line is in poor contact or the control signal has not been adjusted for a long time, resulting in the restoration of the setting.

    3. Check whether the control wiring is honest and whether there is any poor contact. After adjusting the control setting information from the new one, restart the controller after the settings are completed according to the manual.

    4. Many humidifier controllers need to be powered off when they are not used frequently, and they cannot be placed with electricity for a long time. This reaction will occur if the controller is damaged or the line connection is weak, and the adjustment is not correct.

    5. If you are not sure after checking, check whether the humidifier is faulty, the control switch is good, and the humidifier does not work after giving the humidifier signal.

  4. Anonymous users2024-02-09

    Summary. The indicator light of the humidifier does not light up and the machine does not work (1) There are two reasons why the humidifier does not work: one is that the fuse tube is burned out;The second is that there is damage to the device in the entire circuit.

    2) If it is the first one, try to change the fuse first, and it can basically be solved;If it is the second type, go to a professional maintenance point for maintenance. (3) If you are not very familiar with the physical circuit, it is recommended to negotiate with the store where you purchased the item, and the store will help you repair it. (4) If you are familiar with physics, you can check by yourself to check whether the power socket has an AC voltage of 220V, if not, check the socket and line;If so, check whether the fuse FU is fused;If it is not fused, check the power cord and power transformer of the humidifier(5) If the fuse, indicating that there is an overcurrent of the component, at this time, check whether the rectifier diode and Q6 are normal, if the rectifier diode breaks down, replace it;If Q6 breaks down, it is also necessary to check the cause of damage.

    6) If they are all normal, check the heater EH.

    Excuse me, the humidifier can't start after being plugged in, there is no response, and the light is not on, what is the reason for this?

    The indicator light of the humidifier does not light up and the machine does not work (1) There are two reasons why the humidifier does not work: one is that the fuse tube is burned out;The second is that there is damage to the device in the entire circuit. 2) If it is the first one, try to change the fuse first, and it can basically be solved;If it is the second type, go to a professional maintenance point for maintenance.

    (3) If you are not very familiar with the physical circuit, it is recommended to negotiate with the store where you purchased the item, and the store will help you repair it. (4) If you are familiar with physics, you can check by yourself to check whether the power socket has an AC voltage of 220V, if not, check the socket and line;If so, check whether the fuse FU is fused;If it is not fused, check the power cord and power transformer of the humidifier(5) If the fuse, indicating that there is an overcurrent of the component, at this time, check whether the rectifier diode and Q6 are buried normally, if the rectifier diode breaks down, replace it; If Q6 breaks down, it is also necessary to check the cause of damage. (6) If they are all normal, it is OK to check the heater EH.

    Can you add, I don't quite understand it.

    1. The humidifier is completely damaged and the bench cavity is not energized. 2. Humidification means that the power cord of the humidifier is not plugged in, and the humidifier is not energized. 3. The power of the humidifier is only poor contact with the source line, and there is no power.

    4. The power lamp of the humidifier is damaged, although the humidifier is energized, it cannot be seen that the humidifier is energized. 5. The scale in the humidifier is not cleaned, so it causes no power. 6. The atomizer sheet of the humidifier is damaged, so the humidifier is not energized.

  5. Anonymous users2024-02-08

    Cover excavation reverse construction method. The cover-and-dig reverse construction method is a kind of cover-and-dig method. The construction method is to first build the tunnel (or station) retaining wall, supporting columns and structural roof, and then use the entrance, ventilation duct or separate vertical shaft to construct a single-storey or multi-storey underground tunnel (or station) structure with the top-down reverse construction method.

    This method is between the open excavation method and the concealed excavation method, except that its roof is the open excavation construction, and the rest of the structure is the underground excavation construction. This method is especially suitable for urban areas, densely populated and busy places.

  6. Anonymous users2024-02-07

    Summary. Hello dear, happy to answer for you. The reasons why the humidifier does not respond when pressing the switch are as follows:

    1. The controller is damaged or the control signal is wrong; 2. The control switch line is in poor contact or the control signal is not adjusted for a long time, resulting in the recovery of the setting; 3. There is poor contact in the wiring. You need to readjust the control setting information, complete the setting according to the manual and restart the controller; 4. The humidifier is placed live for a long time, resulting in damage to the controller or virtual welding of the line; 5. The humidifier is faulty, and the machine itself cannot respond to the control. A humidifier is a household appliance that increases the humidity in a room.

    A humidifier can humidify a designated room or be connected to a boiler or air conditioning system to humidify the entire building. If my answer is helpful to you, please give a like, look forward to your like, your efforts are very important to me, and your support is also the motivation for my progress. Finally, I wish you good health and a good mood!

    Hello dear, happy to answer for you. The reasons why the humidifier does not respond when pressing the switch are as follows: 1. The controller is damaged or the control signal is wrong; 2. The control switch line is in poor contact or the control signal is not adjusted for a long time, resulting in the recovery of the setting; 3. There is poor contact in the wiring.

    You need to readjust the control setting information, complete the setting according to the manual and restart the controller; 4. The humidifier is placed live for a long time, resulting in damage to the controller or virtual welding of the line; 5. If the humidifier fails, the machine itself cannot be controlled. A humidifier is a household appliance that increases the humidity in a room. The humidifier can humidify the key room room between the specified rooms, or it can be connected to the boiler or air conditioning system to humidify the entire building.

    If my answer is helpful to you, please give a like, look forward to your like, your efforts are very important to me, and your support is also the motivation for my progress. I wish you good health and a happy mood again!

  7. Anonymous users2024-02-06

    If there is no electricity, it may be burned out or the wire is broken, so I won't do it or take it to the electrical appliance shop to repair it, ask the price first.

  8. Anonymous users2024-02-05

    The reason for the circuit device is ,,, well.

  9. Anonymous users2024-02-04

    Summary. Generally, the humidifier works normally, but if the indicator light is not lit, it is because the indicator light is burned out, in this case, buy the same indicator light on the market, and then solder it with an electric soldering iron. Of course, there may also be a broken line, the humidifier has been used for a long time, the circuit is unstable and prone to problems, if the warranty period has not passed, take it for free repair, connect a line or change a small LED lamp It doesn't cost much.

    The second situation is when the humidifier's indicator light does not light up and the machine does not work.

    There are two reasons why the humidifier does not work: one is that the fuse tube is burned; The second is that there is damage to the device in the entire circuit.

    Shanshui SJS-180 humidifier.

    If it's the first one, try changing the fuse first; If it is the second type, then it can only be repaired at a professional maintenance point. If you are not familiar with the physical circuit, it is recommended that you go to the store where you purchased the item to negotiate a solution.

    If you are familiar with physics, you can check by yourself to check whether the power socket has an AC voltage of 220V, if not, check the socket and wiring; If so, check whether the fuse FU is fused;If it is not fused, check the power cord and power transformer of the humidifierIf the fuse is blowing, it means that the component is overcurrent. At this time, check whether the rectifier diode and Q6 are normal, and replace them if the rectifier diode breaks down; If Q6 breakdown, the cause of the damage should also be checked. If they are normal, check the heater EH.

    Humidifier plugged in and not responding?

    Generally, the humidifier works normally, but if the indicator light is not lit, it is because the indicator is burned out, in this case, buy the same indicator light on the market, and then solder it with an electric soldering iron. Of course, it may also be that the circuit is broken, the humidifier has been used for a long time, the circuit is unstable and easy to have problems, if the warranty period has not passed, take it for free maintenance, even a line or change a small LED light does not cost much The second situation is that the indicator light of the humidifier is not lit, and the machine does not work The reason why the humidifier does not work is that there are two situations: one is that the fuse tube is burned; The second is that there is damage to the device in the entire circuit.

    Shanshui SJS-180 humidifier If the stool fails to block is the first type, try to change a fuse tube first; If it is the second type, then it can only be repaired at a professional maintenance point. If you are not familiar with the physical circuit, it is recommended that you go to the store where you purchased the item to negotiate a solution. If you are familiar with physics, you can check by yourself to check whether the power socket has an AC voltage of 220V, if not, check the socket and wiring; If so, check whether the fuse FU is fused;If it is not fused, check the power cord and power transformer of the humidifierIf the fuse is blowing, it means that the component is overcurrent.

    At this time, check whether the rectifier diode and Q6 are normal, and replace them if the rectifier diode breaks down; If Q6 breakdown, the cause of the damage should also be checked. If they are normal, check the heater EH. Hello.

Related questions
7 answers2024-07-10

My computer was the same some time ago, the power light flashed when it was turned on, the hard disk light did not order, there was no alarm, the power supply fan and CPU fan were also turning, but the monitor could not be lit. I began to unplug and unplug the memory module, still no, afraid of bad contact, unplug the wires in the host again, still no, I got it for a long time, didn't do it the computer there, after a while, and then clicked on, beep, it turned on smoothly, (it was estimated that it was too hot), and then I restarted the computer, the problem came again, I couldn't turn on the machine several times, and after hanging there for an hour, I turned on it again, and entered the system smoothly. I didn't dare to turn off the phone at will these days.,Once the phone is turned off, I have to wait an hour to turn on normally.,Everything didn't work until yesterday when I changed the memory.。

9 answers2024-07-10

Hello: Which phone are you?

You can try pressing and holding the power button + volume button down + volume button for three seconds at the same time to see if there is any response. Thank you. >>>More

4 answers2024-07-10

1. The reasons why the laptop does not respond when it is connected to an external speaker are: >>>More

10 answers2024-07-10

Please make sure it's January 1, 2008 (computer time).

Open the license and look up the next 2007 and found that it is the same 1 string as 2007 31 sat 2007 (this English I scribbled anyway is English and is the abbreviation of December) found this easy to solve. >>>More

17 answers2024-07-10

Causes

The rice cooker circuit is not connected to the power supply. >>>More