1. Booster pump.
What is the reason for not being able to pump water.
1. The booster pump cannot pump water, which may be caused by the low water level. If the tap water level is lower than the impeller level of the booster pump, the water will not be pumped. You can wait until the water level rises before using the booster pump.
The booster pump cannot pump water, or because there is no water in the pump, so make sure that there is enough water in the pump and pipeline when the booster pump pumps water. In this case, we can fill the pump with water.
2. The booster pump cannot pump water, which may also be caused by the blockage of the inlet and outlet pipe diameters. We turn off the power of the booster pump, clean it, and then reinstall it and debug it normally. If the booster pump cannot pump water, it may be that the product is faulty, and you can ask a professional to repair it.
Second, what should be paid attention to when installing a booster pump.
When we install the booster pump, we first check whether the product parts are loose, damaged, or blocked. When installing, it should be installed according to the installation method described in the product description, and it should be noted that the direction of the arrow of the pump body should be the same as the direction of the water flow. The booster pump pipes should be tightly connected to avoid the problem of air leakage in the pipes.
A valve switch can be installed at the inlet pipe of the booster pump, and a pressure gauge can be installed at the outlet.
This is more convenient for everyone to use and maintain. The first time you use the booster pump, fill the pump with water.
-
Pressure pumps not getting water can be caused by a variety of reasons. To solve this problem, you can check and deal with it from the following aspects:
Venting: Make sure there is no air inside the pump. Air affects the pump's self-priming ability. Open the pump's vent valve or fill the pump with liquid to expel air.
Check the inlet pipe: Check the inlet pipe for blockages, air leaks, or damage. If there is a problem, clean up the blockage, repair the leak and replace the broken pipe.
Check the working condition of the pump: Make sure the pump is in good working condition. Check whether the motor is operating normally and whether the speed of the pump meets the design requirements. Check whether key components such as impellers, shafts, and seals are worn or damaged, and replace damaged parts in time.
Check the water absorption depth: Check whether the water absorption depth of the pump exceeds the self-priming range of the pump. If the self-priming range is exceeded, the suction depth needs to be reduced or the pump can be replaced.
Check the power supply and voltage: Make sure that the power supply is normal and the voltage is within the allowable range. Low voltage can cause the motor speed to drop, affecting the pump's pumping capacity.
Check the water source: Check if the water source is sufficient, if the water source is insufficient, you need to find other water sources.
Check the installation and commissioning of the pump: Make sure that the pump is installed correctly and that the connection between the pump and the system piping is tight. At the same time, the pump is properly tuned according to the actual needs of the system to meet the pumping requirements.
Choose the right pump: Choose the right pump based on the pressure and flow requirements of the system. If the pump model is not matched, it may not provide sufficient pumping capacity. When selecting a pump, the actual needs and safety margins of the system should be considered.
Through the above methods of inspection and treatment, the problem of pressure pump not watering can usually be solved. If the problem is still not resolved, it is recommended to seek professional help for a comprehensive diagnosis and repair of the system.
-
Hello, I am glad to answer for you, the water pump is a self-priming jet pump This kind of pump can not be blocked at the outlet, otherwise it will cause the gas in the pump to be unable to be discharged, and the pump will naturally not be able to pump water normally. The solution is very simple: connect an automatic exhaust valve to the outlet of the water pump, install a check valve near the interface of the pressure tank, and connect the water pipeline between the check valve and the pressure tank.
That's it.
-
1. The water pump has not been running for a long time, which makes the impeller and sealing parts bonded, resulting in motor blockage; Before starting the machine, the water pump should be coiled to confirm that the rotation is flexible before starting.
2. The pump itself is defective, and there is a dead center when it is coiled, so it should be dismantled to check whether the parts of the pump are damaged.
3. For electrical faults, check whether the motor and line have phase loss faults, and whether the protection system has any malfunction, and test the machine after elimination.
No stress may be the following:
1. The cathartic pressure of the pipeline may be caused by the leakage of a certain part of the pipeline, so that the system pressure decreases; At this point, you can close the outlet valve and check the pressure.
2. Lack of water, insufficient water source in the pipeline is also one of the reasons for insufficient pressure, at this time, the noise of the pump can be heard after starting, and the sound of gradually closing the outlet valve will gradually decrease.
3. Impeller corrosion or impeller mouth ring wear; 4. Judge whether the pressure gauge is normal.
-
What is the problem that the high-pressure water pump has no pressure.
1. It is possible that the nozzle is subject to serious wear, and there will be no pressure, and the nozzle has to be replaced if it is seriously worn.
2. It may be that the water filter is blocked, which will lead to insufficient water intake, so take out the filter and wash it with clean water.
3. It is possible that the internal components of the high-pressure water room pump are worn, resulting in no pressure, if the wear is serious, the new high-pressure water pump has to be replaced.
-
1. The pressure cannot go up due to the inhauling of air in the high-pressure water pump or water inlet pipeline, so you only need to intermittently pull the trigger of the high-pressure water gun, reduce the working pressure of the high-pressure cleaner and run for a while until a stable pressure is generated;
2. If the pressure is not up due to insufficient water supply, first check whether the water level of the water tank is too low, whether the water inlet pipe has leaked out of the water surface and whether the water inlet pipe is leaking and taking rock, at this time, it is necessary to add water to the water tank or replace a new water inlet pipe; If it is a non-self-priming pump, it is necessary to check whether the pressure of the water source is sufficient and whether the inlet flow rate meets the requirements of the pump;
3. The pressure cannot go up due to the blockage of the water inlet filter, so you only need to clean the water inlet filter.
-
There are several reasons why the pressure reputation is too small: 1. If the inlet of the pump is full, when there is no pressure in the pump used for the first time, it is likely that the pump is reversed.
2. There is air in the water supply pipe and pump body. 3. The suction range is too large. 4. The resistance loss of the inlet and outlet pipes is too large.
5. The pump inlet is blocked or the water inlet is insufficient. 6. The motor speed of the centrifugal pump is too low.
-
The pressure of the pump is not bent on the fiber, and the water in the pump and the pipeline is very hot, the frequency conversion control display is normal, the motor can rotate The pipeline is blocked or there is a valve sock imitation door that is not opened, and the water will heat up if it idles in the pump casing.
-
If the pipeline is clogged or the valve is not opened, the water will heat up if it idles in the pump casing.
-
The pressure of the two pumps will definitely increase, but the second pump should not be installed on the outlet of the previous pump, and the outlet of the two pumps should be connected to the same mother pipe.
-
There may be several reasons why the pressure of the pump cannot go up:
Excessive inlet resistance of the pump: If the inlet pipe of the pump is too long, bent or there is resistance, it will cause the suction pressure of the pump to decrease, and the inlet pressure will be insufficient, which will affect the outlet pressure of the pump.
The inlet filter of the pump is clogged: If the inlet filter of the pump is clogged with debris, it will cause the pump to absorb insufficient water and the inlet pressure to decrease, which will affect the outlet pressure of the pump.
Worn or low speed of the pump: If the impeller of the pump is worn or the speed is too low, it will cause the flow rate of the pump to decrease and the outlet pressure to decrease.
The drain pipe of the pump is too long or the resistance is too large: If the drain pipe of the pump is too long, bent or there is resistance, the drain pressure of the pump will be reduced, and the outlet pressure will be reduced.
Pump shaft seal leakage: If the shaft seal of the pump is leaking, it will cause the efficiency of the pump to be reduced, which will affect the pump outlet pressure.
Unstable supply voltage: If the supply voltage is unstable, it may cause the speed of the pump to be unstable, which will affect the outlet pressure of the pump.
For these reasons, it is necessary to deal with them accordingly, such as: optimizing the pipe design, cleaning the filter, replacing the impeller, reducing the pipe resistance, replacing the shaft seal, ensuring the stability of the power supply voltage, etc., to increase the outlet pressure of the pump.
-
Summary. If there is a small fault in the water pump, make sure it does not work, if the sealing gasket of the pump shaft is worn, it must be added in time, if you continue to use it it will leak, the direct effect of this is to increase the energy consumption of the motor, thus damaging the impeller.
Hello, dear . I am very happy to answer the questions for your manuscript ruining, I am your dedicated and repentant electronic answerer Zou Zou, what is the reason why the water pressure of the water pump does not go up is as follows.
1. Pump reversal** If the side mouth of the pump is full, it is likely that the pump is reversed when there is no pressure in the pump for the first time. 2. There is air in the water supply pipe and pump body.
3. The suction range is too large. 4. The resistance loss of the inlet and outlet pipes is too large. 5. The pump inlet is blocked or the water inlet is insufficient.
6. The motor speed of the centrifugal pump is too low.
If there is a small fault in the water pump, please make sure it does not work, if the gasket of the pump shaft is worn, it must be added in time, if you continue to use it in the town it will leak, so the direct effect of this is to increase the energy consumption of the motor, thereby damaging the impeller.
1. What is the reason for the insufficient pressure of the water pump? >>>More
What should I do if there is no pressure in high-pressure water? It is recommended that you go to a professional repair place to repair it.
Being stressed is not necessarily a bad thing, but too much pressure can easily make you lose self-confidence and even lose direction; If you have any questions, you must ask the teacher for advice in time, so that the teacher can grasp your situation and propose a solution to the problem, so that your problem can be solved in time and relieve your pressure. >>>More
Summary. f=p*s, this is the most fundamental principle, you see, the motor drives the oil pump to produce 10MPa hydraulic oil, the hydraulic oil enters another container, the size of the force generated is related to the surface area, as shown in the figure, there is a difference between S1 and S2 on both sides, and the force of S1 can be calculated by the formula F=PS, and the force of S1 and S2 is the same, then P2=F1 S2, the greater the difference between S1 and S2, the greater the force of F2, and that's it. Soul painter, please don't mind. >>>More
It's good to be young and suffer more, but it doesn't mean that you have to force it on you against your will. Sometimes you have to learn to say no. If the top shift is something outside of your position, there is no reason why you should help for free. >>>More