Photovoltaic intelligent cleaning robot (Lier Sunshine cleaning robot) effectively improves power generation, this way is better to clean, photovoltaic power station intelligent cleaning is an inevitable development trend of fine operation and maintenance of power stations, only more intelligent, in order to reduce labor investment, reduce labor costs.
-
The surface of the photovoltaic module should be kept clean, and the photovoltaic module can be wiped with a soft and clean cloth that is dry or damp, and it is strictly forbidden to use corrosive solvents or hard objects to wipe the photovoltaic module.
There are three main ways to clean photovoltaic modules, manual cleaning, high-pressure water gun cleaning and professional equipment cleaning.
1. Manual cleaning: The cost of manual cleaning is relatively low, and it is suitable for roofs with a relatively small area. Because the personnel is not easy to manage, it is easy to wear and tear the module glass, which affects the power generation and life of the power station.
2. High-pressure water gun cleaning: The high-pressure water gun has a good cleaning effect, but the water consumption is large, and if the water gun pressure is too large, it will easily cause hidden cracks in the components.
3. Professional equipment cleaning: the water consumption of professional equipment cleaning is small; The cleaning speed is fast and the effect is good, but it is more suitable for the site with a wide distance between the front and rear of the module, due to the non-linear motion of the vehicle, the pressure on the component is uneven, and it needs to be operated by professionals.
At the same time, the bracket also needs to be maintained, and the maintenance of the bracket should ensure that all bolts and bracket connections should be firm and reliable; The anti-corrosion coating on the surface of the bracket should not crack and fall off, and if there are cracks and falling off, the paint should be repaired in time.
1. The cleaning frequency of the battery board should be ensured, and the specific situation should be determined according to the cleanliness of the surface of the battery board.
2. The operation and maintenance should be tracked diligently, the inspection should not go through the motions, and the data inspection of all aspects of the background should not be less than once an hour, and whether the tracking data has changed greatly.
3. Timely discovery of hidden dangers in a timely manner, phalanx inspection can not be less than once a day (especially at noon when the irradiance is relatively high, focus on observing the inverter and indoor temperature, to ensure good heat dissipation), to ensure that the attendance rate of power generation efficiency is high, 4, to ensure that there are a certain number of spare parts, wearing parts and other small components, to ensure that once there is a problem can be replaced in time without affecting the power generation efficiency. O&M is not only limited to the operation and maintenance of the power station, but also ensures the normal income of the power station owner, and efficient operation and maintenance can maximize the income of the power station.
Huayang Green Building; Solar power generation.
-
Answer: Responsible for the production preparation of the new photovoltaic power station, and cooperate with the relevant departments of the company to complete the control and management of the project quality inspection process; 2. Responsible for the operation, inspection, elimination, meter reading, settlement and other related work of the photovoltaic power station after it is connected to the grid to ensure the smooth completion of the company's power generation goals; 3. Responsible for the formulation of various operation and maintenance instructions, operation and maintenance reports, and the establishment of operation and maintenance files; 4. Complete other tasks assigned by superiors.
-
Photovoltaic operation and maintenance can be understood in two aspects:
First, the dirtiness of the surface affects the transmittance of light, which in turn affects the amount of radiation received on the surface of the module.
Second, because the surface of the module is very close to the cell, it will form a shadow and form a hot spot effect in the local area of the PV module, which will reduce the power generation efficiency of the module and even burn the module.
Proper cleaning of photovoltaic panels can prolong the service life of photovoltaic power stations, improve the work efficiency of photovoltaic panels, and thus increase power generation.
Lier Sunshine photovoltaic panel cleaning robot is lightweight, portable, easy to load and unload, and can be carried with the vehicle, which can easily provide portability for the operation and maintenance team to work at multiple points.
-
Test with components as clean as possible.
Attach the temperature sensor to the backplane in advance to save time.
If the deviation between the measured value and the estimate is large, test it several times.
Check and re-check before setting off for the test, and bring an extra spare battery.
The connection between the instrument and the component to be tested must be tight, do not leave a gap, place the instrument in a room temperature environment after returning from the site, and pay attention to waterproof, moisture-proof and high-temperature protection.
Keep the irradiance sensor at the same angle as the component to be measured and pay attention to occlusion to ensure that the instrument is clean and tidy, especially the interfaces, buttons, and screen parts.
-
What are the precautions for daily maintenance of photovoltaic power plants?
Recommended by the person who asked the question.
Anonymous users1. Maintenance of modules and brackets (1) The surface of photovoltaic modules should be kept clean, and the photovoltaic modules should be wiped with dry or damp soft and clean cloths, and it is strictly forbidden to use corrosive solvents or hard objects to wipe the photovoltaic modules. The PV module should be cleaned when the irradiance is lower than 200W, and the liquid with a large temperature difference with the module should not be used to clean the module. (2) Photovoltaic modules should be inspected regularly, and if the following problems are found, the photovoltaic modules should be adjusted or replaced immediately.
PV modules have glass crushing, scorching backsheets, and obvious color changes; The presence of air bubbles in the PV module that form a communication channel with the edge of the module or any circuit; The junction box of the PV module is deformed, twisted, cracked or burned, and the terminal blocks cannot be in good contact. (3) The live warning sign on the photovoltaic module shall not be lost. (4) For photovoltaic modules with metal frames, the frame and bracket should be well combined, the contact resistance between the two should not be greater than 4, and the frame must be firmly grounded.
5) When working under the condition of no shading, under the condition that the solar irradiance is more than 500W and the wind speed is not more than 2ms, the temperature difference on the outer surface of the same photovoltaic module (the area directly above the cell) should be less than 20. Photovoltaic power stations with an installed capacity of more than 50kWp should be equipped with infrared thermal imaging cameras to detect the temperature difference on the outer surface of photovoltaic modules. (6) Use a DC clamp ammeter to measure the input current of each photovoltaic module string connected to the same DC combiner box under the condition that the solar radiation intensity is basically the same, and its deviation should not exceed 5%.
7) All bolts, welds and bracket connections of the bracket should be firm and reliable, and the anti-corrosion coating on the surface should not crack and fall off, otherwise it should not be brushed in time.
-
Removal of contaminants, maintenance of components and brackets, maintenance of combiner boxes, maintenance of inverters, maintenance of cables, maintenance of extreme weather – Amerisolar PV modules
-
The photovoltaic panel intelligent cleaning robot has a unique waterless cleaning mode for the operation and maintenance of household distributed photovoltaic power stations, and has obvious advantages for small photovoltaic power stations on the roof or courtyard of family houses.
-
In the design process, the power station is standardized, scientific, reasonable and accurate selection, and at the same time, good operation and maintenance habits must be continuously carried out in the later stage, so that the power generation of the power station can be guaranteed in the later stage.
-
Operation managementThe operation requirements of the power station are special types of workers。The operation personnel should monitor, operate and adjust the parameters of the power generation equipment throughout the day, and must work consistently and repeatedly to ensure the safe, economical, stable operation of the equipment of the whole plant and the correctness of the safety measures for equipment maintenance.
1. Responsible for the duty and maintenance of photovoltaic power station.
2. Operate the power station equipment in accordance with the technical specifications of the power station to ensure the normal operation of the power station.
3. Responsible for organizing the economic operation of photovoltaic power stations in accordance with the "Photovoltaic Power Station Operation Management Standards" and relevant regulations.
4. Responsible for the data analysis and report management of the operation of the photovoltaic power station.
5. After the photovoltaic power station is completed and connected to the grid, operation and maintenance has become the focus of the work of the photovoltaic power station, and the operation and maintenance work is directly related to the long-term normal and stable operation of the power station, and is related to the operation and maintenance cost, investment value and final income of the photovoltaic power station.
Electricity price subsidy. Now the state's subsidy for the photovoltaic industry is the policy issued in August 2013, the "Notice on Leveraging to Promote the Healthy Development of the Photovoltaic Industry" (Fa Gai ** [2013] No. 1638), which stipulates the subsidy policy for distributed generation, the first subsidy of yuan kilowatt hour, and the implementation period is 20 years in principle.
The state will gradually reduce electricity prices and subsidy standards according to changes in the scale and cost of photovoltaic power generation. At the end of 2017, the state adjusted the subsidy to yuan. Various provinces and cities have formulated different subsidy standards according to policies, which are basically the following:
National subsidy + provincial subsidy + municipal subsidy + county-level subsidy (the latter three if any) = the final PV feed-in tariff.
-
I must rely on your company qualifications to do operation and maintenance.
-
1. Dust cleaning of marble floor: For the dust on the marble floor, it should be cleaned regularly, and professional dust pusher or electrostatic vacuum cleaner should be used to clean the ground as much as possible.
2. Ordinary stains on the surface of marble: local stains on the marble floor can usually be removed by wiping with a mop or rag.
3. There are often some special stains on the marble floor, if it is accidentally stained with ink or chewing gum and other colored stains, this situation must be dealt with in time. The usual practice is to use a damp towel to gently pat and press the stain, wait until the color of the ground is absorbed by the towel, and then use a clean towel to wipe it off.
4. Stains that are difficult to clean: For large areas or stains that are difficult to clean, a special strong concentrated cleaning agent for marble should be used, which can effectively remove organic pollution, or the cleaning agent is dissolved with decontamination powder, or the enzyme cleaning agent that can effectively remove vegetable stains is dissolved with decontamination powder, and then attached to the stain with the mixture, after a period of time, the stain is sucked off, and then cleaned with a wet towel.
5. Scratches: Dealing with scratches requires polishing, and in this case, professionals can be invited to deal with them.
6. Yellowing: You can use multi-functional detergent to clean. It is mainly a waterproofing agent to apply cleaning paste to the cracks in the ground. This is mainly for wet places such as bathrooms.
7. When using cleaning agents, you must choose ZTE's cleaning agents, and you cannot use acid and alkaline cleaning agents such as laundry detergent and detergent. When using a strong concentrated detergent or enzyme detergent, it is necessary to test the treatment in a small area to ensure that the detergent will not cover the surface of the stone with dark marks. If you use a mop to mop, make sure that the mop is wrung out before dragging.
-
After the renovation, the ground will be stained with all kinds of stains, so you must hold the method before cleaning, so that it will not be troublesome to deal with. Cleaning of the ground: After the façade wall, glass, balcony, kitchen, and bathroom are done, the ground is cleaned, and the ground should also be clearly distinguished, whether it is a wooden floor, polished brick, high-gloss brick, plastic floor or natural stone, artificial stone, when the material is clear, choose a special cleaner to dilute and start cleaning.
The glue stains on the ground can be cleaned with a glue remover, and after the last process is completed, the foreman will check it thoroughly and evacuate the site after confirming that there is no residue.
-
With the development of modern intelligent technology, the country vigorously develops new energy such as solar energy, wind energy, and hydropower, after years of development, especially the clean operation and maintenance of photovoltaic power stations is particularly important, and the maintenance of photovoltaic power stations, especially large-scale photovoltaic power stations, must adopt modern operation and maintenance mode, and use mechanical intelligence to replace manual cleaning work of photovoltaic power stations.
-
Power station operation and maintenance is the abbreviation of solar photovoltaic power generation system operation and maintenance, is based on system safety, through preventive maintenance, periodic maintenance and regular equipment performance testing and other means, scientific and reasonable management of the power station, in order to ensure the safe, stable and efficient operation of the entire power station photovoltaic power generation system, so as to ensure the return of investors. The demand for water is very high. Many companies use robots to clean power plants.
Operation managementThe operation requirements of the power station are special types of workers。The operation personnel should monitor, operate and adjust the parameters of the power generation equipment throughout the day, and must work consistently and repeatedly to ensure the safe, economical, stable operation of the equipment of the whole plant and the correctness of the safety measures for equipment maintenance. >>>More
The photovoltaic agriculture integrated grid-connected power generation project combines solar power generation, modern agricultural planting and breeding, and high-efficiency facility agriculture.
Zhejiang has the most photovoltaic enterprises, you can go and see.
Installation quota 12 volume 7 chapter 1 section of the solar power supply part check which quota set, installation quota book 2 electrical equipment installation does not have photovoltaic related quota subheading.
For photovoltaic companies, of course, it is the pursuit of profits; At present, most of China's photovoltaic products are exported, which does not contribute much to China's own energy structure. >>>More