Questions about the inspection and acceptance of elevators and parking lots

Updated on society 2024-08-04
16 answers
  1. Anonymous users2024-02-15

    That's not right, although they are all special equipment, but he doesn't have this right, you can go and complain and try it, ask for a statement. Go to the special equipment inspection and testing agency to report for acceptance, and then they send someone to accept, then they will notify you in advance, after the acceptance is completed, you go to the designated bank to pay the fee, and then take the payment form to the special equipment inspection and testing agency to receive the report, and at the same time take the payment slip for the invoice. Then take the report to the Quality and Technical Supervision Bureau for registration, and take the relevant information to the special inspection institute to get the license after registration.

  2. Anonymous users2024-02-14

    1, because the special inspection institute is in charge of this, 2, yes, 3, the special inspection institute is a subordinate unit of the quality supervision bureau, 4, the declaration and acceptance are not the same in various places, but the basic is to submit the start of the notice, self-inspection report, quality certificate, information table, the front is the original, the back copy with the red seal, installation instructions, maintenance instructions, electrical diagrams, hoistway diagrams, construction plans, installation qualifications, installation qualifications, installation personnel qualifications, safety components type test report, safety gear and speed limiter debugging copy, complete machine certificate, The rest depends on the needs of the local special inspection center.

  3. Anonymous users2024-02-13

    I guess it's regional. The special equipment in Hebei has been separated from the pot inspection institute. All of them belong to the subordinate units of the Quality and Technical Supervision Bureau.

    Accredited, of course. Hehe. The thought.

    **We shouldn't be arrogant to this extent.

  4. Anonymous users2024-02-12

    Elevator inspection and acceptance method:

    1. The speed limiter action speed setting seal must be intact and there are no traces of dismantling. In order to prevent other personnel from adjusting the speed limiter and changing the action speed, the safety gear will malfunction or reach the action speed and cannot operate.

    2. When the safety gear is adjustable, the setting seal should be intact and there should be no traces of dismantling. In order to prevent other personnel from adjusting the safety gear, causing it to lose its due effect.

    3. The tensioner of the governor and its limit switch should be installed correctly in the opposite position.

    4. The gap between the safety gear and the guide rail should meet the product design requirements.

    5. When the car stands at both ends of the leveling position, the distance between the car, the counterweight buffer hitting plate and the top surface of the buffer should meet the requirements of the civil engineering layout drawing. The deviation between the center of the collision plate and the center of the buffer should not be greater than 20mm.

    6. The plunger sag of the hydraulic buffer should not be greater than that, and the liquid filling amount should be correct.

  5. Anonymous users2024-02-11

    The elevator inspection is still required at this time of the next year, but the inspection time needs to be applied for about a month between the next elevator inspection. For example, if you pass the inspection on April 5, 2012, the next inspection will be on April 5, 2013

  6. Anonymous users2024-02-10

    It is organized and implemented by the Bureau of Quality and Technical Supervision. It depends on the local situation.

  7. Anonymous users2024-02-09

    After the installation of the elevator, it should pass the inspection and acceptance of the special equipment safety supervision and management department.

    In accordance with the "Regulations on Safety Supervision of Special Equipment".

    Article 20, boilers, pressure vessels, elevators, lifting machinery, passenger ropeways, large-scale amusement facilities installation, transformation, maintenance and field (factory) of special motor vehicles, maintenance after completion, installation, transformation, maintenance of the construction unit shall be within 30 days after acceptance of the relevant technical data handed over to the use of the unit, high energy consumption special equipment should also be in accordance with the requirements of the safety technical specifications to submit energy efficiency test report. The user shall store it in the safety technical file of the special equipment.

    Article 21, boilers, pressure vessels, pressure pipeline components, lifting machinery, large-scale amusement facilities manufacturing process and boilers, pressure vessels, elevators, lifting machinery, passenger ropeways, large-scale amusement facilities installation, transformation, major maintenance process, must be approved by the special equipment safety supervision and management department of the inspection and testing institutions in accordance with the requirements of safety technical specifications for supervision and inspection; Those that have not passed the supervision and inspection shall not be delivered or delivered.

  8. Anonymous users2024-02-08

    According to the "Regulations on the Safety Supervision of Special Equipment", DU Article 20 BOILERS, pressure vessels, pressure piping DAO components, lifting machinery back.

    The manufacturing process of large-scale amusement facilities and the installation, transformation and major maintenance process of boilers, pressure vessels, elevators, lifting machinery, passenger ropeways, and large-scale amusement facilities must be supervised and inspected by the inspection and testing institutions approved by the special equipment safety supervision and management department in accordance with the requirements of safety technical specifications; Those that have not passed the supervision and inspection shall not be delivered or delivered.

    Therefore, after the installation of the elevator, the installation and acceptance should be carried out by the local special equipment inspection and testing agency.

  9. Anonymous users2024-02-07

    According to the "Regulations on Safety Supervision of Special Equipment" and TSG T7001-2009, the annual inspection cycle of elevators is one year.

    Article 28 of the Regulations on the Safety Supervision of Special Equipment stipulates that "the user of special equipment shall, in accordance with the regular inspection requirements of the safety technical specifications, submit regular inspection requirements to the special equipment inspection and testing institution one month before the expiration of the validity period of the safety inspection." Therefore, check the date of the last annual inspection report or supervision and inspection report of the elevator, and submit regular inspection requirements to the local special equipment research institute (or special equipment inspection institute) in writing or ** after 11 months of the date, and pay the inspection fee according to the relevant charging standards. Elevator annual inspection standards, inspection system according to the "Special Equipment Safety Supervision Regulations" Article 28 provisions:

    Special equipment that fails to pass the regular inspection shall not continue to be used. The elevator is regularly inspected once a year, and the user must report to the special equipment inspection institute one month before the expiration date of the previous year's inspection certificate to determine the specific inspection date. 1. The user shall prepare the following information and matters:

    1) Special equipment registration form. 2) Periodic inspection report of the previous year (including rectification opinions). 3) Elevator calculation data.

    4) The policy maintenance contract issued with Weiwei. 5) The management system of the elevator of the unit. 6) Pay the regular inspection fee.

    2. Matters to be prepared by the maintenance unit: 1) The repair and maintenance qualification certificate of the unit; Certificate of entrustment from the manufacturer (copy with official seal). 2) Under normal circumstances, maintenance personnel should be prepared to cooperate with the inspection.

    Inspection 1 - 6 at least 2 inspection 7 - 10 at least 4 inspection 11 - 20 at least 6 2, receive the inspection report and certificate: 1), the elevator that is inspected as "qualified" elevator can directly receive the inspection report and certificate within 10 days. 2) The elevator to be inspected is qualified, but there is a rectification project of the elevator, the maintenance unit needs to complete the rectification, and fill in the results, by the elevator user in the rectification opinion stamped on the official seal of the inspection report and certificate.

    3) The elevator that is inspected and concluded to be unqualified shall be re-inspected by the maintenance unit after rectification. The user shall affix the official seal to the rectification opinion to confirm, and after passing the re-inspection, handle the inspection report and certificate.

  10. Anonymous users2024-02-06

    According to the elevator installation supervision and inspection and regular inspection regulations (July 30, 2004, the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China) Article 3:

    The elevator to be put into use after installation shall be inspected in accordance with the content and requirements of the installation supervision and inspection provisions in accordance with these regulations; For the elevator to be put into use after the general project transformation and major maintenance (hereinafter referred to as the overhaul) of the elevator, should be in this regulation on the basis of the content and requirements of the regular inspection, in addition to the inspection of the transformation and overhaul project, the inspection of the transformation and overhaul project should be carried out according to its specific situation, according to the relevant content and requirements of the installation supervision inspection or the acceptance inspection of the original regulations; When the transformation project is to increase the rated speed of the elevator, increase the rated load, increase the weight of the car, and change the driving mode, the inspection shall be carried out in accordance with the content and requirements of the installation supervision and inspection provisions of this regulation; The elevator in use shall be inspected once a year in accordance with the content and requirements of the regular inspection of these regulations. When the safety and technical performance of the elevator may be affected due to natural disasters or equipment accidents, after overhaul, it shall be inspected in accordance with the requirements of the installation supervision and inspection of these regulations.

  11. Anonymous users2024-02-05

    Yes. On January 9, 2002, the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China issued the "Elevator Supervision and Inspection Regulations".

    stipulates that the elevator in use shall be inspected once a year in accordance with the content of the regular inspection provisions of this regulation.

  12. Anonymous users2024-02-04

    It is required to be inspected every year and to be declared two months in advance.

  13. Anonymous users2024-02-03

    There are some elevators that I remember have some inspection certificates.

    There is an item above that writes the date of the next test:...

    This means that it should be tested on time.

  14. Anonymous users2024-02-02

    The elevator inspection standards are as follows:

    GB T10060-1993 "Elevator Installation and Acceptance Code", GB T10058-1997 "Elevator Technical Conditions", GB T10059-1997 "Elevator Experimental Conditions", GB7588-1995 "Elevator Manufacturing and Installation Safety Code", TSG T7001-2009 "Elevator Supervision and Inspection and Periodic Inspection Rules", GB T18775-2002 "Elevator Maintenance Code", GB50310-2002 Elevator Engineering Construction Quality Acceptance Code".

    Elevator production standards:

    GB T 10059-1997 Test Methods for Elevators.

    GB T 10058-1997 Technical conditions for elevators.

    GB 50182-93 Electrical Installation Engineering Elevator Electrical Installation Construction and Acceptance Code GB Rubber Insulated Cables with Rated Voltage 450 750V and Below Part 5 Elevator Cables GB Rated Voltage 450 750V and Below Rubber Insulated Cables Part 5: Elevator Cables.

    GB 10060-93 Elevator installation acceptance code.

    GBJ 310-88 Quality Inspection and Evaluation Standard for Elevator Installation Engineering.

    GB 7588-87 Safety code for elevator manufacturing and installation GB 11625-89 Marine freight elevators.

    GB 10059-88 Test Methods for Elevators.

    GB 10058-88 Elevator Technical Specifications <>

  15. Anonymous users2024-02-01

    The elevator daily maintenance unit shall, in accordance with the requirements of the elevator use and maintenance manual, formulate a daily maintenance plan, make daily maintenance records, and ensure the safety and technical performance of the elevator.

    The daily maintenance of the elevator includes the following:

    1) Clean, lubricate, adjust and inspect the elevator and safety facilities at least once every 15 days;

    2) Inspect the appearance and operation of safety devices, wire ropes, brakes, contactors and other running parts at least once a month;

    3) Conduct a safety test on safety devices, speed limiters and buffers every six months;

    4) Conduct a braking ability test of mechanical brakes once a year;

    5) Conduct a comprehensive inspection of the elevator operation condition at least once a year.

  16. Anonymous users2024-01-31

    The style of the elevator certificate.

    The elevator certificate refers to the elevator after the elevator has been inspected by the national certified elevator inspection qualification unit, and the local technical supervision department will issue a certificate that the elevator can be used safely within a certain period of time.

    According to the provisions of the "Regulations on the Safety Supervision of Special Equipment" issued by the company, the annual inspection cycle of the elevator is one year. Only elevators that pass the annual inspection can be put into use.

    Extended Resources:

    The product certificate refers to the certificate, label or seal attached to the product or product packaging by the producer to show that the product has passed the quality inspection. This is an express guarantee made by the producer for the quality of its products, and it is also a product identification obligation undertaken by the producer under the law. Taking electronic products as an example, the product certificate should include the following contents in addition to the model, name, specification, production unit and address of the product.

    1) Implement the product standard number.

    2) Inspection items and their results or inspection conclusions. Products delivered in batches should also have: batch, batch number and part number of the sampled inspected piece, etc.

    3) The inspection date, the date of delivery, and the signature or seal of the inspector (can be indicated by the inspector's code).

    An elevator is a vertical lift powered by an electric motor with box-like pods that are used to carry people or goods in multi-storey buildings. There is also a stepped type, and the tread plate is mounted on the track for continuous operation, commonly known as escalator or moving walk. Stationary lifting equipment serving the specified floors.

    A vertical lift has a car that runs between at least two rows of rigid rails that are vertical or have an inclination angle of less than 15°. The size and structure of the car are convenient for passengers to enter and exit or load and unload goods.

    It is customary to use elevators as a general term for vertical transportation within a building, regardless of the mode of drive. According to the speed, it can be divided into low-speed elevator (less than 1 meter second), fast elevator (1 2 meters second) and high-speed elevator (more than 2 meters second). Hydraulic elevators began to appear in the mid-19th century, and they are still used on low-rise buildings today.

    In 1852, Otis of the United States developed a safety elevator for wire rope lifting.

    In the 80s, the drive device was further improved, such as the electric motor driving the winding drum through worm drive, the use of counterweight, etc. At the end of the 19th century, friction wheel transmission was adopted, which greatly increased the lifting height of the elevator.

    At the end of the 20th century, the elevator was powered by a permanent magnet synchronous traction machine. It greatly reduces the area of the computer room, and has the advantages of low energy consumption, high energy efficiency and fast lifting speed, which greatly promotes the development of real estate in the direction of super high-rise.

    Interpretation of the provisions of the product identification and labeling provisions of the Supervision and Management Department of the State Bureau of Technical Supervision:

    There are three main forms of product quality inspection certificates: certificate of conformity, conformity label and qualification seal.

    The products that pass the inspection are labeled with the qualification mark.

Related questions
13 answers2024-08-04

The parking lot must be fully or mostly responsible! Because the parking lot is a custody contract, it is not a site lease relationship. Although the vehicle is not turnkeyed, it does not affect the storage object as a static vehicle. >>>More

9 answers2024-08-04

Vehicle entry judgment, vehicle parking management, vehicle payment management, vehicle exit judgment.

17 answers2024-08-04

There are a total of 1,700 parking spaces, and the charging standard is 10 yuan for 2 hours, 5 yuan per hour after 2 hours, 90 yuan a day for overnight stays, and 120 yuan per day after 3 days. >>>More

5 answers2024-08-04

The following methods have basically not heard of not entering the parking space) in the non-zigzag parking lot, it is recommended to choose reversing, and then operate as follows: >>>More

17 answers2024-08-04

I think there are still a lot of luxury cars parked in the parking lot, such as Mercedes-Benz, Rolls-Royce, Audi, Lincoln, etc.