How thick the wires should be and how big the meter should be installed in such a large oven

Updated on home 2024-08-06
4 answers
  1. Anonymous users2024-02-15

    When this oven uses single-phase electricity, 3 sets of heating rods are used in parallel, and the current is: The line should be 10 square aluminum wire or 6 square copper wire. The meter is: 10-40 can be, the main switch is 63a, and the wiring at the end of the meter must be tightened, otherwise the meter will be burned out.

  2. Anonymous users2024-02-14

    The 60A meter is logically enough for your home, but you can't just look at the meter, and the meter won't trip. The meter is 60A, and the air switch and leakage switch should also go up to 60A, which is usually 63C. The wire is also very critical, the connection between the front and back of the meter and the main switch (air switch and leakage switch) needless to say, at least 10 square copper wires should be used, the rapid voltage of the oven should be exceeded, the line from the main switch to the oven should use 6 square copper wires, the main switch to the air conditioner and electric hot water switch should also use 6 square meters, and the other lines depend on the electrical power consumption, so that it will not trip.

  3. Anonymous users2024-02-13

    It depends on how much power the oven is, such as Joyoung's household generally1500w, the current is, it is enough to use a square copper wire, because the interception of the square copper wire is13a, that is to say, the square copper wire can be with:220v×13a=2860w,The other can also look at the power cord of the oven, which is generally marked on the wire, and the 1500w mark isSquare copper wire, small power, thin wire.

    Inside the red box are the wires".

  4. Anonymous users2024-02-12

    I believe that many friends know that the wire is divided into flat, flat, 4 flat, 6 flat, and 10 equal according to its cross-sectional area, and the number of cores is also different, but this is not important, the important thing is that we know that the socket generally uses a flat wire, but can the kitchen be?

    Even if the half package has a lot of materials are purchased by the decoration company, they will fool the owner, the kitchen appliances use a lot of electricity, if you open it together, it is better to open it 4 squares, in fact, the maximum power of the wire is 4500W, even if the kitchen small appliances are opened together, it is completely bearable, and the lamps and lanterns are opened up separately, so it is completely more than enough for this circuit.

    For safety reasons, it is advisable for the power of the wire to not exceed 3000W, otherwise it will be overloaded for a long time and pose a threat to the safety problem.

    Some low-power appliances in the kitchen do not need 4 square wires, while large power items such as air conditioners and water heaters may need 4 square wires. Living room, bedroom and other sockets, lighting can be used square wires.

Related questions
9 answers2024-08-06

Presumably an electric heating wire heated oven.

9 answers2024-08-06

When using an electric oven, the following should be noted: >>>More

7 answers2024-08-06

Hello, I think it's best to use coarse sand to lay the bottom of the reef tank, because coarse sand is not easy to turn the sand up due to the movement of fish, and coarse sand is also convenient for cleaning fish feces and other garbage.

6 answers2024-08-06

To the common ones, the coarse ones to the coarse.

9 answers2024-08-06

The single-strand copper core wire, because generally, at 25 times, the rated current that 1mm copper core wire can pass through is 4 7A, generally when we choose, we should enlarge a little, for the sake of insurance, the wire used, long-term through this current, is safe.