What is the cause of the leakage of the indoor unit of the air conditioner, why does it not leak dur

Updated on home 2024-03-22
12 answers
  1. Anonymous users2024-02-07

    The main problem is that the outlet pipe of the indoor unit is blocked. You can open the front face of the indoor unit of the air conditioner, and at one end of the water inlet under the cross-flow fan, there is a water outlet blocked by dirt, just dredge it. Use a thin wooden stick or twig to poke the water outlet pipe of the indoor unit to poke out the dirt, or use a vacuum cleaner to suck the water out of the outlet pipe of the indoor unit, being careful not to suck the water into the vacuum cleaner (except for suction vacuum cleaners).

  2. Anonymous users2024-02-06

    Is there a water leak when the air conditioner is turned on, and there is no water when the air conditioner is not turned on. If this is the case, it is normal, the water that comes out is condensation, which is condensed due to the hot air encountering the cold air, and is generally connected to the outside or toilet with a PVC pipe or plastic hose.

  3. Anonymous users2024-02-05

    Turn off the power first, wipe the water, and then use it after ten minutes, basically it's fine, if the next day is still like this, the same treatment, generally not a big problem, the third day will not drip water into the house, is the outdoor drain is a little dirty and blocked, repeated several times on the dust, long-term so to the manufacturer warranty, two or three days later, if there is no problem, you can not need to report for repair, water leakage must be turned off the power, wipe it thoroughly, and then ten minutes, restart.

  4. Anonymous users2024-02-04

    That's because of the principle of thermal expansion and cold contraction, the temperature of the air conditioner may change during use, so that there are some small spaces that may be opened intermittently.

  5. Anonymous users2024-02-03

    Temperature effects. The temperature is not stated.

    In summer, the temperature is high, the indoor temperature does not drop below 30°C, and the temperature does not drop until 10 o'clock in the evening, and of course the indoor temperature is dropping.

    The obvious condensation is too much at night.

    There may be water vapor in hot pot for dinner, water vapor evaporation in tea and boiled water, evaporation in vegetable soup, high water vapor, low temperature of air conditioner, condensation of water in the chassis, and water moisture in the ceiling.

    During refrigeration work, the water vapor in the air meets the cold air, and the water mist and condenses into water.

    Condensation droplets do not come together and come out of the drain pipe, which may cause water leakage.

  6. Anonymous users2024-02-02

    Have you noticed the condensation at this location? Let's do it here, either diversion or insulation.

  7. Anonymous users2024-02-01

    There is a high probability that the drain is blocked.

  8. Anonymous users2024-01-31

    1.Internal machine offset.

    If the air conditioner is installed improperly or a part is loose, resulting in an imbalance between the left and right, one side is high and the other is low, which will cause the air conditioner to tilt and the drain pipe to divert water on the high side, resulting in difficulty in drainage, and water will seep out through the gap of the air conditioner.

    Solution: Readjust the installation position of the air conditioner, tighten the set screws at the same time, and lower the drain pipe.

    2.The mounting position is too low.

    If the main condensate discharge of the cold and bright condensate is in the form of "water flowing to a low place", the air conditioning hole will usually be lower than the height of the air conditioning installation when the air conditioner is installed, and if the slope is not enough, the condensate will not be able to flow out, and it can only be accumulated in the water basin of Liu Hui.

    Solution: Plan well during decoration, and if you are not enough, you can only re-open the hole.

    3.Insufficient refrigerant.

    When the air conditioner is running in the case of lack of fluorine, it is easy to cause the evaporator to freeze, and when the ice melts into water droplets, the water droplets will drip directly from the gap of the air conditioner to the room, resulting in water leakage in the air conditioner.

    Solution: Contact after-sales maintenance to replenish the refrigerant for the air conditioner.

    4.Clogged drains.

    If the drain pipe is blocked, the condensate in the air conditioner will not be able to discharge the first dust normally, and it will flow back to the lowest point of the indoor unit and flow out from the air outlet of the air conditioner.

    Solution: Pull out the end of the outdoor drain pipe and blow a lot of air into it until the blockage is blown open, and the water can naturally be discharged smoothly.

    5.The filter is too dirty.

    If the filter screen is too dirty, it will cause stains to stick to the evaporator, the evaporator will not be able to exchange heat, the work efficiency will be reduced, the refrigeration effect will be worse, and the power consumption will also increase.

    Secondly, when both the filter and the evaporator are dirty, the surface will become uneven, and the condensate will not flow back to the specified location, but will flow out from various positions in the internal unit.

    Solution: Take out the filter and clean it.

  9. Anonymous users2024-01-30

    Generally, the cooling effect of air conditioners at night is better than that during the day, and the corresponding condensate production at night is also larger than during the day.

    Causes and solutions of air conditioner water leakage:

    1. Improper installation or offset position of the internal machine.

    Especially for newly purchased machines, the leakage of the machine is mostly caused by improper installation, such as uneven installation or too high position of the outlet pipe protruding from the outside.

    Another reason may be that the installation of the fixed hanging plate of the indoor unit is not particularly firm, and it is loose, and the internal unit of the air conditioner has a certain displacement, which has caused drainage difficulties and caused dripping water in the internal unit of the air conditioner.

    Solution: Reinstall it due to water leakage caused by improper installation. During installation, the installation position of the air conditioner needs to be re-measured, and the position of the air conditioner drain port needs to be appropriately lowered to ensure that the condensate of the air conditioner can flow out of the air conditioner smoothly through the drain pipe, and fix the fixed hanging plate of the indoor unit.

    2. The drain pipe is blocked.

    When the drain pipe is blocked, the condensate of the air conditioner cannot be discharged smoothly, and can only flow out through the internal unit.

    Solution: The drain pipe is blocked, you can first see if the drain pipe mouth is blocked, and there is also a reason that the air conditioner is blocked due to too much dust, if the check is because the drain pipe is blocked, you can use a high-pressure water gun or other tools to flush it, and dredge it.

    3. Drainage pipe quality problems.

    If the quality of the drainage pipe is not very good, it is easy to appear aging and slack, which is easy to cause the pipe to bend and affect the smooth drainage.

    The solution: replace the drain with a new one!

    4. The heat exchanger of the air conditioner drips.

    This problem is mainly related to the filter screen, such as the filter screen that has not been cleaned for a long time, too much dust, which will lead to the deterioration of the hydrophilic aluminum foil of the air conditioner.

    Solution: Clean the filter regularly.

  10. Anonymous users2024-01-29

    You look closely to see if it is the water leaking in which part of the indoor unit, the machine or the pipe.

  11. Anonymous users2024-01-28

    The air is dry during the day and humid at night, so it leaks.

  12. Anonymous users2024-01-27

    In the hot summer, the company of air conditioning is always indispensable. Nowadays, most of the household air conditioners use split air conditioners, that is, the kind with outdoor units and indoor units. However, in the process of use, it is sometimes foundThe indoor unit of the air conditioner is leakingphenomenon, so is this phenomenon normal?

    Is it normal for the air conditioned room or the internal unit to leak water?

    The air conditioner is actually the body indoors, so if it drips in real use, is it normal? Then here is to tell you, if there is a dripping phenomenon in the air conditioner of your home, it means that there is a problem. Because under normal circumstances, the condensate produced by the air conditioner will enter the water storage tray and then be discharged through the drain pipe of the air conditioner, so we often see the air conditioner outdoor unit pipe dripping down, rather than the air conditioner indoor unit leaking.

    Introduction to the causes and solutions of water leakage in the air conditioning room

    1. The drainage pipe is blocked.

    Blocked drain pipes are also a common cause of water leakage in the indoor unit of the air conditioner, because if the drain pipe is blocked, it will make the condensate of the air conditioner unable to drain out, and it will naturally flow out from the internal unit. The main reasons for clogged air conditioner drain pipe are: the drain pipe mouth is blocked, or the drain pipe is blocked due to too much dust inside the air conditioner.

    Solution: Check whether the drain is unobstructed first, if there is a blockage, then just unblock it.

    2. Improper installation or offset of the internal machine.

    The installation of air conditioners is actually relatively professional, and professionals are generally required to install it. Of course, sometimes they will inevitably be installed improperly, such as the indoor unit fixed baffle plate is not installed firmly, and it will be displaced after a long time, which will cause drainage difficulties, and eventually lead to water leakage of the indoor unit of the air conditioner.

    Solution: If it is not installed properly, then it should be reinstalled. When re-installing, the installation position of the air conditioner should be re-measured, and the position of the air conditioner drain should be lowered, so that the condensate of the air conditioner can flow out of the air conditioner smoothly through the drain pipe.

    3. Dripping water from the heat exchanger of the air conditioner.

    Why does the air conditioner heat exchanger cause its internal unit to drip water? Actually, it has something to do with the filter. For example, if there is too much dust on the filter screen, it will lead to the deterioration of the hydrophilic aluminum foil of the air conditioner, so that the condensate on the evaporator cannot flow directly into the sink when the air conditioner is refrigerated, and finally drip into the room through the internal machine.

    Solution: If this is the reason, it is also very easy to solve, as long as the filter is thoroughly cleaned.

    The above is about the air conditioner, is it normal for the indoor unit to leak? The detailed answer to the reason for the dripping of the indoor unit of the air conditioner, I don't know if you are satisfied with our introduction.

Related questions
8 answers2024-03-22

If it is a washing machine with a wave wheel:

1. If it is a washing machine, it may be that the drain pipe is not fixed and rotten, and it is more likely to appear in the machine for more than two years. >>>More

10 answers2024-03-22

Causes of water leakage in the air conditioner:

1. The common reason for water leakage of the external unit of the air conditioner is this, the drain pipe is from the internal machine, and the internal unit blows hot air during heating, so there will be no condensation, such as the dripping water at the bottom of the external unit is also normal. Because the external machine blows cold air during heating, the defrosting function of the machine will be reduced when it is old, and the radiator of the external unit will frost or even freeze, and after the machine is automatically frosted or shut down for a long time, the frost will melt away and it will drip water. >>>More

22 answers2024-03-22

Possible reasons why the treadmill cannot start: 1. The power supply is not on; 2. The fuse is blown; 3. The switch of the electric treadmill is broken; 4. For other reasons, please contact our professionals. Workaround: >>>More

8 answers2024-03-22

The reasons are as follows: low battery;

The battery is low; >>>More

5 answers2024-03-22

If the air conditioner is not cooling, you can troubleshoot it by following these steps:1Incorrect usage mode Please check the set mode: >>>More