Mitsubishi elevator Lingyun 2 how to seal and weigh

Updated on Car 2024-03-01
6 answers
  1. Anonymous users2024-02-06

    Mitsubishi Elevator. Lingyun 2 how to seal the weighing process is actually very simple, set1=4, set0=0, sw1 downward confirmation, when the seven segments of the code display in the lower right corner of the two points in turn flashing is completed.

  2. Anonymous users2024-02-05

    1. set1=4, set0=0, sw1 to confirm downward.

    2. The two dots in the lower right corner of the seven-segment code display can be flashed in turn.

  3. Anonymous users2024-02-04

    Adjustment of weighing devices.

    a. No-load NL write.

    1) The elevator is located in the middle of the shaft and is empty.

    2) Place set1 "6" and set0 "2" on the p1 board

    3) Press the "SW1" on the P1 board to the " " side, the 7-segment code will display the current value and flash, and it will automatically exit the SET after writing

    mode, 7 segments of the code into mon mode.

    4) Place the P1 board on mon1 "0", mon0 "d", press the SW2 switch up, and the 7-segment code will display the no-load data, and it is true.

    Recognize that the no-load write is successful.

    How to confirm that the elevator is located in the middle of the shaft:

    Place the p1 board mon1 "0", mon0 "1", the elevator runs manually, when the display changes to "0" to "-0", it means that the elevator car elevator is located in the middle of the shaft.

    b. Half-load BL write.

    1) The elevator is located in the middle of the shaft and is half loaded.

    2) Place set1 "6" and set0 "3" on the P1 board

    3) Press the "SW1" on the P1 board to the " " side, the 7-segment code will display the current value and flash, and it will automatically exit the SET after writing

    mode, 7 segments of the code into mon mode.

    4) Place set1 "0" and set0 "8" on the P1 board

    5) Place mon1 "0", mon0 "d" on the p1 board, press the sw2 switch upwards, and the 7-segment code will display half-load data.

    Recognize that the half-load write is successful.

    6) Place the P1 plate on mon1 "1", mon0 "0".

    7) Press the RST switch on the P1 board to save the no-load and half-load data in the ROM.

    c. Unbalanced load writes.

    1) The elevator is located on the ground floor and is empty.

    2) In automatic operation mode, pull the DCB FMS to the FMS position, then let go, and the floor display will start flashing.

    3) Close the door, the elevator will automatically run from the ground floor to the top floor, and after reaching the top floor, the floor display will stop flashing.

    d. Fine-tuning of overload action points.

    1) Auto running mode, 110% load.

    2) Adjust the switch WGHO until 29W is activated, the car door stays open, and the overload buzzer sounds.

    e. Fine-tuning of load weighing device.

    1) If the car has the feeling of lifting up and pulling when starting, then rotate the switch WGHG in the direction of "F", 2) If the car has the feeling of sinking during starting, then rotate the switch WGHG in the direction of "0".

  4. Anonymous users2024-02-03

    EC external board is bad Unplugged layer by layer, which fault is gone, which is broken. Lingyun maintenance writes and weighs the middle point of the elevator shaft, set1 is set to 0, set0 is set to 5, SW1 is lowered, and the maintenance is written.

  5. Anonymous users2024-02-02

    Mitsubishi Elevator Lingyun 2 how to seal the weighing process is actually very simple, set1=4,set0=0,sw1 downward confirmation, when the seven segments of the code display in the lower right corner of the two points in turn flashing is completed.

  6. Anonymous users2024-02-01

    Summary. The sealing and weighing operation steps of Lingyun 2 elevator are as follows:1

    First, locate the elevator control panel. Usually located on the wall next to the elevator door. 2.

    Locate the "Seal Weighing" button on the panel. In the Lingyun 2 elevator, the button is generally marked with a ruler icon. 3.

    Press the seal button and follow the instructions on the panel. The specific mode of operation may vary depending on the elevator model. 4.

    According to the actual use and needs of the elevator, adjust the value of the sealing and weighing. Seal weighing is usually related to the load capacity of the elevator to ensure that the seal weighing setting is reasonable and meets safety requirements. Keep in mind that the adjustment of the seal weighing involves the safety of the elevator, and if you are unsure or unfamiliar with the operating procedures, be sure to consult a professional maintenance personnel or contact the elevator manufacturer for assistance.

    The sealing and weighing operation steps of Lingyun 2 elevator are as follows:1First, locate the elevator control panel.

    Usually located on the wall next to the elevator door. 2.Locate the "Seal Weighing" button on the panel.

    In the wide Lingyun 2 elevator, the button is generally marked with a ruler icon. 3.Press the seal button and follow the instructions on the panel.

    The specific mode of operation may vary depending on the elevator model. 4.According to the actual use and needs of the elevator, adjust the value of the sealing and weighing.

    Seal weighing is usually related to the load capacity of the elevator to ensure that the seal weighing setting is reasonable and meets safety requirements. Keep in mind that the adjustment of the seal weighing finger involves the safety of the elevator, if you are unsure or unfamiliar with the operating procedures, be sure to consult a professional maintenance personnel or contact the elevator manufacturer for assistance. God-only.

    Excuse me, but please go into more detail?

    The sealing and weighing operation steps of Lingyun 2 elevator are as follows:1Locate the elevator control panel, which is usually located on the wall next to the elevator door.

    2.Locate the "Seal Scale" button labeled with the ruler icon on the panel. 3.

    Press the Seal Weigh button and follow the instructions on the panel. 4.According to the use and needs of the elevator shout, adjust the value of the sealing and weighing.

Related questions
15 answers2024-03-01

Mitsubishi PLC programming program how to write PLC Hello, 1, after the program is written, you need to transform the program first, there are three ways to transform: the first is to press the F4 key of the keyboard directly, the second is to click the "transform" menu bar, and then click the first item "transform", the third is to click the "program transform" button of the toolbar, we choose the appropriate transformation method according to their own habits 2, after the program is transformed, you need to check whether there are syntax errors in the program, This check only self-diagnoses the syntax, not the design content. To check the program, click "Program Check" in the menu bar of the tool. >>>More

11 answers2024-03-01

There are still very few in the country, very little, very little.

9 answers2024-03-01

TO is to write the command of the special function module, that is, to send the data in the PLC to the special function module and buffer memory BFM. >>>More

18 answers2024-03-01

Heavy industry and motor belong to the "father-son" relationship. Founded in 1870, Mitsubishi Heavy Industries has a history of more than 100 years, and with the development of Mitsubishi Heavy Industries, Mitsubishi Electric was later separated from Mitsubishi Heavy Industries and became an independent company. MHI's refrigeration technology uses advanced manufacturing technologies such as aerospace and biotechnology. >>>More

21 answers2024-03-01

Daikin is Gree's OEM, which is a bit fantastical. Gree bought inverter technology from Daikin. Daikin can be said to be the leader of air conditioning. >>>More