Hello, to do a clean operating room, first of all, you need to have a professional design plan, as well as the corresponding engineering team, clean operating room includes: electrolytic plate, electric airtight door, steel airtight door, stainless steel medicine cabinet, instrument cabinet, anesthesia cabinet, purification light strip, medical sink, laminar flow ceiling, etc. The hospital should also have a ** room, operating room, etc.
-
The purification equipment that needs to be configured in the clean operating room project mainly includes: air purification equipment; ultraviolet sterilization and disinfection equipment; sterilization and disinfection equipment for surgical instruments; Surgical gloves, clothing sterilization and disinfection equipment, etc. If you need purification equipment for the operating room, it is recommended that Liaoning Hao clean equipment manufacturing ****, their home mainly serves the hospital operating room, ** room, laboratory department; Pharmaceutical workshop, dust-free electronic food workshop, as well as various laboratory supporting purification products.
1. Operating room: electrolytic plate, electric airtight door, steel airtight door, stainless steel medicine cabinet, instrument cabinet, anesthesia cabinet, purification light strip, medical handwashing basin, laminar flow ceiling, etc.
2. Pharmaceutical factory: air shower room, cargo shower room, purification transfer window, ordinary transfer window, high-efficiency air supply outlet, LED purification panel light, steel airtight doors and windows, FFU filter unit, etc.
3. Laboratory: all-steel test bench, fume hood, etc.
4. ** room: sterilizer, cleaning machine, drying cabinet, stainless steel dirt washing tank, inspection and packing table, etc.
Their company's products are all over the Northeast and surrounding areas, and are deeply loved by customers, hoping to help you.
-
Generally, the operating room only has a general area (no need to purify), a 100,000-level area (an auxiliary area such as changing clothes, etc.), and a 10,000-level area (an operating area).
-
The clean operating room is generally divided into several levels, so you should go to the hospital and ask the relevant doctor or relevant books to check it.
-
The clean operating room can usually be divided into 3 areas, namely: clean area, clean area, and contaminated area.
a.Cleaning area: including office, locker room, duty room, family waiting area, etc.
b.Clean area: including conversation room, anesthesia preparation room, sterile instrument room, operating room, clean corridor, etc.
c.Contaminated areas: polluted corridors, sewage washing rooms, isolation sewage washing rooms, packing rooms, etc.
Laminar flow purification of the operating room not only requires highly clean air (the air entering the operating room must first be purified by a high-efficiency filter), but also requires the flow direction of the airflow (i.e., the use of laminar flow ultra-clean device), so that the airflow flows from the surgical area with high cleanliness to the area with low cleanliness, and takes away and discharges the dust particles (dust particles) and bacteria in the airflow; Laminar flow is a fine, thin-layered stream of air that is transported in the same direction at a uniform flow velocity; There are two types of purified airflow: vertical laminar flow and horizontal laminar flow. The following is an introduction to the purification level and cleanliness level of China's operating room by Anhui Renhe and Purification.
Level differentiation of laminar flow decontamination operating rooms.
30min 90 dishes (10 m3) 5 cm2 1000 grade (local 100 grade).
30min 90 dishes (50 m3) 5 cm2 10000 grades.
4 x 30min 90 dishes (150 m3) and 5 x cm2 100000 grade.
5 x 30min 90 dishes (175 m3) 5 x cm2 300000 grade.
Cleanliness level Applicable type of surgery Room arrangement.
Class 100 (extra clean) Valve Replacement, Cardiac Surgery, Organ Transplantation, Joint Replacement, Neurosurgery, Operating Room.
Class 1 000 (Standard Clean) Ophthalmic Surgery, Plastic Surgery, Non-systemic Burns, Orthopedics, Class I Surgery in General Surgery, Hepatobiliary and Pancreatic Surgery Cardiopulmonary bypass perfusion preparation room.
Class 10 000 (General Clean) Thoracic Surgery, Urology, Obstetrics and Gynecology, Otorhinolaryngology, General Surgery (except for Class I surgery) Operating room, sterile room.
Class 100 000 (General Clean) Outpatient, Emergency, Infectious Surgery, General Burn Corridor, Restroom, Anesthesia Preparation Room.
-
The frequent occurrence of wound infections has brought many complications to surgical procedures, turning what would have been successful into a disaster.
Sexual results. Difficult surgeries such as large-scale burn surgery, cranial surgery, eye surgery, lung surgery, and mediastinal surgery are required.
It must be performed in an ultra-clean environment to minimize the infection rate of surgery and ensure the success of the surgery.
Laminar Pure Operating Room is a multi-functional air purification measure that filters dust particles from the air so that bacteria are free.
vector transmission, so as to effectively prevent and control the occurrence of infection, while providing a suitable temperature and humidity environment to keep the patient in hand.
Minimal tissue damage is required during surgery.
The clean operating room is divided into four levels, and the air cleanliness level is the necessary guarantee condition
Comparison of operating room cleanliness levels and ISO standards:
The highest level of operating room purification, Class 100 purification, is equivalent to an ISO5 clean environment, and the concentration of pollutants is 10,000 times higher than that of an ISO1 environment.
-
96267452 purification industry***, come to the group to communicate.
-
3.Technical requirements for the operating department.
Decorative walls and ceilings.
The wall and ceiling of the operating department are made of antibacterial 50 series foam sandwich color steel insulation board, tongue and tongue type, thickness is, double-sided film, the wall of the clean operating room must achieve seamless, airtight effect, the color meets the requirements of the modern operating room, the visual perception is comfortable, the ceiling height of the operating room is meters, and the ceiling of other auxiliary rooms is meters.
The clean corridor and changing workshop are equipped with a 150mm wide and stainless steel anti-collision belt at the height of the trolley.
Ground cement self-leveling.
The floor of the operating room, clean corridor and auxiliary room is made of antistatic, anti-corrosion, wear-resistant, uniform color 2 mm PVC membrane, and the flange height around the operating room is 120 mm.
The seams of the coils are all hot welded and welded, smooth and seamless, and are connected with the wall in arcs.
The basic configuration of the operating room.
Each operating room is equipped with a medical electric suspended automatic push-pull airtight door on one side of the clean corridor, using motors and controls, with a headroom of not less than 1400mm*2000mm, foot sensory control, and a door"During surgery"lamp, the door is surrounded by stainless steel edging. The door body is provided with inspection, the middle is provided with an anti-collision belt, the height and width of the door are designed according to the standard, and the door in other areas adopts the color steel plate purification door.
The operating room is equipped with an anesthesia cabinet, an instrument cabinet and a medicine cabinet, and the cabinet body is made of stainless steel plate, and the size is: 900*1700*300 (width * height * depth).
Each operating room is equipped with a quadruple light box and a writing table.
Stainless steel brush pool, thick stainless steel tank, outer color steel plate, including induction faucet, 2 hand dryers and 2 soap dispensers. Each sink is equipped with a 40L electric water heater.
The basic configuration of each operating room.
-
Henan laminar flow operating room purification.
In special industries such as biological science, with the deepening of various researches, the requirements for the environment are getting higher and higher, and how to make the indoor environment meet the requirements is the premise of various researches. This is how the laminar flow purification operating room project may have been born and expanded.
In a fixed spatial range, the moisture, harmful substances, and bacteria contained in the air can be reasonably regulated by certain means. Laminar flow purification operating room engineering is such a work, by changing the air pressure of the airflow, so that the indoor environment can reach a certain standard, so as to meet the production and work.
Laminar flow purification operating room engineering is a systematic work, and there are different types of books according to different classification standards. From the control of the airflow, it is divided into turbulent flow, compound and laminar flow. The first is turbulence, which is a common one in the laminar flow purification operating room project, which mainly filters the indoor air by the air duct, so that the air in the clean room is returned, and the movement of the air flow will improve the quality of the indoor air; The second is laminar flow, which is to make the airflow move evenly through the laminar flow purification operating room project, and can make the partition board return air, which is suitable for the use of clean rooms with higher equivalent.
The latter is a composite type, that is, a combination of the second method, which is more suitable for the cleaning of small areas.
Laminar flow purification operating room engineering is a relatively technical industry, and it is necessary to choose the appropriate purification method according to the characteristics of the object and the scope of use. For many large electronic production enterprises, the laminar flow purification operating room project is more suitable for turbulent flow, because it can ensure the effective control of the air in the indoor supervision, avoid environmental disturbance in the production process, and more importantly, the noise can also be reasonably and effectively controlled.
Clean corridor workshop.
After the completion of the complete decoration of the operating room, the clean corridor including the entrance and exit of each floor must be operated and used in strict accordance with the requirements in the operating room, and the qualified laminar flow operating room purification is the premise of a perfect operation, and the biological indicators are reasonable, so as to ensure that the air in the operating room is clean and free of germs, so as to add another layer of guarantee for the success of the patient's operation!
The operating room is a high-risk area for nosocomial infection, and the implementation of effective infection control management in the operating room is an important link and guarantee to control the nosocomial infection. >>>More
Teaching is equivalent to one of the functions of the digital operating room, the teaching is to record the surgical process, and then the digital operating room has more functions, which can broadcast the whole process of the operating room in real time, and the teaching system is relatively cheaper. Some manufacturers are mainly imported, which is expensive, and the domestic Liande is good, and they are developed by themselves, which are affordable, and these are all advantages.
Air purification in the operating room is a complex project, but its significance is far-reaching, after the purification of the operating room, the air in the operating room can achieve a clean and pollution-free state, so that the patient can heal as soon as possible. As a specialist in the field of operating room purification, Renhe Purification brings you acceptance criteria and post-maintenance solutions for operating room air purification. >>>More
The operating room is strictly divided into three areas: sterile area, clean area, semi-clean area, contaminated area and unclean area. >>>More