It is better to leave the air conditioner in the elevator machine room that does not run at night. This can ensure that the temperature and humidity in the computer room are controlled at a constant temperature.
-
I think it is better to turn on the air conditioning in the elevator machine room at night, because the weather is drier now, and it is more stuffy, if the temperature is too high, it may also cause the elevator to malfunction, it is recommended to open it better.
-
The machine room of the elevator is designed for the high temperature of the elevator controller of the house, although there are not many people who use the elevator at night, if you still want to start the machine, the air conditioner is still better to turn on.
-
If you don't run. In general, it is possible to turn off the air conditioner. It's also a waste of electricity when it's on.
-
Look at the environment, some ventilation is better, heat dissipation is also good, can meet the temperature of the operating elevator does not need to press the air conditioner, if the heat dissipation is not good, the elevator alarm must be pressed.
-
Even if it is not running, the indoor air conditioner should be turned on, because there are control systems and automation devices in the elevator machine room, and the temperature and humidity in the room need to be maintained.
-
I suggest turning it off and turning off the air conditioner when no one is around.
-
If the elevator doesn't run at night, it's best to turn on the TV for him, because it's very likely that someone will go up directly, and it's dangerous, so it's better to turn it on.
-
It is best to turn on the air conditioner in the elevator machine room, because electronic products have requirements for the operating temperature.
-
The air conditioner in the elevator machine room should preferably run 24 hours a day. At night, if the air conditioner does not work, then the indoor temperature does not rise, and the air conditioner will automatically shut down.
-
Obviously, shut it down. Power saving.
-
To save energy. Can be turned off.
The temperature is low at night.
Can be turned off.
-
Whether the air conditioner of the elevator machine room that does not run at night is turned off or on, it must be turned on, and the host will definitely not heat up and will not affect the operation of the elevator.
-
Of course, the air conditioner in the elevator machine room that does not run at night is turned off. It's useless to turn it on.
-
If it is not running at night, it is best to turn off the air conditioner in the elevator room.
-
Of course, the air conditioner of the elevator machine room that does not run at night is turned off, because it is also conducive to safety performance when it is turned off to save electricity.
-
No, just turn it on when it's wet.
-
No. It is only open in the lowest temperature and hot and humid weather.
-
Just turn on hot days and humid weather, because the control board is afraid of heat and moisture.
-
In order to reduce the temperature of the computer room.
The control cabinet will dissipate heat when working, and if the temperature of the computer room is too high, it will cause the electronic board in the control cabinet to work abnormally, and the electronic board will be damaged in serious cases.
When the machine room is built, the elevator manufacturer will prompt you to leave ventilation holes, and sometimes you can also open the window to dissipate heat, and the elevator manufacturer or maintenance company will prompt you to install air conditioning when the conditions are not met.
1. The elevator machine room should be locked at any time, and the door lock key should be kept by the director of the engineering department;
2. The computer room should be well ventilated, indicating that it meets the requirements, the doors and windows should be closed flexibly, and the temperature in the computer room should be kept between 5 degrees Celsius and 40 degrees Celsius in any season;
3. The computer room should be kept clean and tidy, and it is strictly forbidden to store flammable, explosive or dangerous goods, and other sundries are not allowed to be stacked;
4. The fire-fighting equipment in the computer room should be placed in a prominent position and kept in good condition within the validity period;
5. The elevator machine room should be cleaned once a week;
6. When idle personnel enter the computer room, if they need to enter due to work, they must be approved by the head of the engineering department and accompanied by them to enter the computer room;
7. Personnel who have not obtained the "Special Equipment Operation Certificate" shall not use and operate the elevator equipment at will;
8. The elevator worker shall keep the surface of the equipment and facilities in the machine room free of dust, rust, oil stains and dirt in accordance with the provisions of the "Safety Operation Regulations". Ensure the normal operation of the elevator;
9. When the elevator machine room is stopped due to repair and maintenance, a notice board should be hung up at the base station.
-
The control cabinet dissipates heat when it operates.
If the temperature of the computer room is too high, it will cause the electronic board in the control cabinet to work abnormally, and if it is serious, it will damage the electronic board, and the elevator manufacturer will prompt you to leave ventilation holes during the construction of the computer room.
Sometimes windows can also be opened to dissipate heat.
When the conditions are not met, the elevator manufacturer or maintenance company will prompt you to install air conditioning.
-
No. There is no mandatory requirement to install air conditioning in the temperature of the elevator machine room; It is only mentioned in the code and rules: GB7588-2003 "Safety Code for Elevator Manufacturing and Installation" Ventilation: Stale air extracted from other parts of the building must not be directly discharged into the machine room.
Motors, equipment and cables should be protected as far as possible from dust, harmful gases and moisture.
Safety Technical Specifications for Special Equipment "Rules for Elevator Supervision and Inspection and Periodic Inspection - Traction and Forced Drive Elevators" TSG T7001 2009 Article 15: When inspecting the elevator machine, the inspection site shall have the following inspection conditions: the air temperature in the machine room or between the machinery and equipment shall be kept between 5 and 40.
In actual use, the temperature of the machine room is kept within the above range, the stable operation and service life of the elevator is beneficial, and the core temperature of the motor is about 40 ° when the elevator host is running, but in the high temperature environment, it will definitely promote the aging of the equipment.
-
The national standard does not have a standard for temperature, but it has requirements for ventilation, and manufacturers have requirements for temperature, generally 5-40 degrees.
In GB7588-2003 "Safety Code for Elevator Manufacturing and Installation", it is mentioned that "the machine room should have proper ventilation". When the elevator is accepted, if there is no exhaust fan, the acceptance personnel of the ** department may not be able to accept.
The technical instructions provided by the elevator manufacturer generally have requirements for the temperature of the machine room, which is often 5-40 degrees. Because the temperature in the elevator machine room is too high, it will affect the heat dissipation of various microelectronic components such as inverters, PLCs, and traction machines in the control cabinet and cause failures. In actual use, keeping the temperature of the machine room within the above range is beneficial to the stable operation and service life of the elevator.
-
GB T10058-2009 Technical Conditions for Elevators The air temperature in the machine room should be kept between +5 and +40.
-
The control cabinet dissipates heat when it operates.
If the temperature of the computer room is too high, it will cause the electronic board in the control cabinet to work abnormally, and the electronic board will be damaged if it is serious.
When the machine room is constructed, the elevator manufacturer will prompt you to leave ventilation holes.
Sometimes windows can also be opened to dissipate heat.
When the conditions are not met, the elevator manufacturer or maintenance company will prompt you to install air conditioning.
-
Usually not required, one is unattended, and the other is the influence of ambient temperature on the unit, which has been taken into account in the product design.
-
If there are conditions, of course, it is good to install air conditioning, and the air adjustment in summer can reduce the temperature of the machine room, reduce the accident rate of the machinery and equipment in the elevator machine room, and prolong the service life of the electrical components of the elevator machine room equipment.
-
The control cabinet will dissipate heat when it is working, and the temperature of the computer room will be too high, which will cause the electronic board in the control cabinet to work abnormally. At this time, the temperature, humidity and other parameters of the indoor ambient air of the air conditioner need to be adjusted and controlled. 4 reasons why you need to install air conditioning in the elevator machine room:
1. Reduce the temperature of the computer room and transfer the heat from the computer room to the outside.
2. Increase the life of equipment and facilities and reduce the maintenance rate and replacement rate, so as to reduce complaints and increase the continuous operation of equipment.
3. When the facility is operated in a high-temperature environment for a long time, the service life will be greatly reduced, and the operation at low temperature will be different, the life will be extended, and the operation will be more stable.
4.When the compressor is running, the mechanical noise generated is high, so the main unit can be placed outdoors to keep the room quiet and comfortable.
-
All the elevator rooms in our project are equipped with air conditioning.
-
Look at the place. Generally, it is recommended that high-rise buildings and southern cities should be installed to reduce the failure rate.
-
The temperature of the computer room should generally be between 5 and 40 rooms.
If it is less than 5, measures should be taken, but hot water or steam should not be used for heating, and above 40 should be used for ventilation or fan or refrigeration and air conditioning, and air conditioning can be installed if the cost budget is sufficient.
When the temperature is suitable, the failure rate can be reduced and the aging of electronic components can be delayed.
Generally, the speed of elevators below 12 floors is 22 to 22. >>>More
When the outdoor temperature is lower than 0 degrees Celsius, the outdoor unit of the air conditioner will immediately frost, and when the user turns on the air conditioner for heating, it takes about 8-12 minutes to "defrost", and some users mistakenly think that the heating effect of the air conditioner is not ideal. 2. Due to improper use and maintenance by users, etc. 3. The reason why the air conditioner cannot work normally is because the power consumption increases greatly, which may cause the regional power supply voltage to be unstable or too low. >>>More
When the air conditioner is turned on during sleep, it is easy to get cold, once there is a cold, the body's resistance will often decrease, and it is easy to have a cold, sore throat or pneumonia, and it may also lead to acute gastroenteritis, such as abdominal pain and diarrhea. >>>More
One reason why the air conditioner doesn't drip water.
1.Whether the machine is refrigerated or not. If the machine is not refrigerated or the cooling effect is not good, the moisture in the air will not condense. >>>More
A normal 8 hours of sleep is enough'It's no good to sleep too much. >>>More