What is the problem with the Menak motherboard showing E13?

Updated on technology 2024-04-28
4 answers
  1. Anonymous users2024-02-08

    Fault description E01 Inverter unit protection E31 Abnormal DPRAM E02 Acceleration overcurrent E32 CPU abnormality E03 Deceleration overcurrent E33 Elevator speed abnormality E04 Constant speed overcurrent E34 Controller logic fault E05 Acceleration overvoltage E35 Shaft self-learning data abnormality E06 Deceleration overvoltage E36 Running contactor.

    Fault E07 Constant Speed Overvoltage E37 Brake Detection Switch Fault E08 Control Power Failure E38 Encoder.

    Signal Abnormality E09 Undervoltage Fault E39 Motor Overheating E10 System Overload E40 Elevator Operation Timeout E11 Motor Overload E41 Safety Loop Fault E12 Input Phase Loss E42 Door Lock Disconnection in Operation E13 Output Phase Loss E43 Upper Limit Disconnection in Operation E14 Module Overheating E44 Lower Limit Disconnection in Operation E15 E45 Simultaneous operation of the upper and lower strong change switches E16 E46 Releveling.

    Abnormal E17 Encoder Signal Verification Abnormal E47 E18 Current Detection Fault E48 Door Opening Fault E19 Motor Tuning Fault E49 Door Closing Fault E20 Encoder Fault E50 Group Control Communication Fault E21 Synchronous Encoder Wiring Fault E51 CAN Communication Fault E22 Leveling Signal Fault E52 External Summoning Communication Fault E23 Short-circuit Fault to Ground E53 Door Lock Shorting Fault E24 E54 E25 Controller Data Abnormality E55 If the door opening of this layer is not in place, the layer is changed and stopped at E26 E56 Control board overspeed e27 e57 e28 e58 e29 star sealing contactor feedback abnormal e59 e30 elevator position abnormal e60

  2. Anonymous users2024-02-07

    Jeddah Honda Elevator E13 Fault Answer: If it is a Menak elevator, the fault of E13**: E13:

    Output side phase loss fault level: 4Fault cause: 1

    The output wiring of the main circuit is loose; 2.motor damage; Fault solution 1Check the wiring; 2.

    Check whether the output-side contactor is normal; 3.Troubleshoot the motor;

  3. Anonymous users2024-02-06

    Failure Cause 1The output of the main circuit is grounded or short-circuited; 2.The connection of the traction machine is too long; 3.overheating of the working environment; 4.The internal wiring of the controller is loose.

  4. Anonymous users2024-02-05

    Is the signal cable plug-in on the dashboard loose? Is the interface of the interface board loose? Is the dashboard broken? Check them one by one.

Related questions
11 answers2024-04-28

Generally speaking, as long as there is a PCI-E x16 expansion slot on the motherboard, you can install a discrete graphics card, but there are also a few graphics cards that also have a rejection effect on the graphics card due to compatibility problems. >>>More

14 answers2024-04-28

I'm using a BA-270, so the options should be the same, so I'll give you a reference. >>>More

8 answers2024-04-28

Hello, the computer playing the game appears, the application: "The memory cannot be read or written"! Chance Occurrence Point [Cancelled]! >>>More

20 answers2024-04-28

First of all, you have to make sure that your graphics card is not a copycat! Colorful GTX550TI seems to have only the Flame God of War U is 2G, if it is a card that is swiped, there will be unexpected things after overclocking. >>>More