Ozone disinfection calculation method.
I did the disinfection plan according to the following disinfection technical specifications. You also have to take into account the structure of the room, the humidity and temperature of the workshop, the items and the disinfection requirements when you actually calculate them. Because ozone is a very reactive and unstable gas, the humidity, temperature, and items in the room will also affect the disinfection effect, so the ozone dosage is appropriately adjusted according to the above situation on this basis.
The reference concentration for the use of ozone in air is 1ppm=
According to the "Disinfection Technical Specification" and practical application experience, 300,000 purification grade C = = 5mg m3;
100,000 purification grade C = 5ppm = 10mg m3;
10,000 purification grade C = 15ppm = 30mg m3;
100 level C = 20ppm = 40mg m3, I hope it can help you!
-
The question should be to know the volume of space disinfection, how to calculate the amount of ozone used or how big to use ozone generator.
The calculation formula is w=c*v d, where c is the concentration of ozone in the required space for disinfection, which is determined according to the disinfection level, such as: 300,000 purification grade C = = 5mg m3; 100,000 purification grade C = 5ppm = 10mg m3; 10,000 purification grade C = 15ppm = 30mg m3; 100 level c = 20ppm = 40mg m3; v is the volume that needs to be disinfected, if the air is supplied with ** air conditioner, the air volume should also be considered, multiplied by a certain coefficient; d is the attenuation coefficient of ozone, which is.
-
It's so difficult、、、 it's decisive, and I can't even do quadratic functions well.
-
Summary. Dear Hello: 700 grams are needed.
Ozone is an allotropic form of oxygen, also known as trioxygen, the chemical formula is O3, as the name suggests, it is a gas with a smell, because ozone has a strong oxidation effect, as well as has a broad-spectrum sterilization, promotes blood circulation in the body, and can also improve the metabolic level of oxygen.
Dear Hello Hunger Sedan Car: 700 grams are needed. Ozone is a kind of oxygen isomorphic form, also known as trioxygen, the chemical formula is O3, as the name suggests, it is a gas with a smell, because ozone has a strong oxidation effect, as well as has a broad-spectrum sterilization, promote the body's blood circulation and redundancy, in addition to improve the metabolic level of oxygen. Dear
-
1. It is recommended to use a dynamic disinfection machine, that is, the kind of disinfection machine that can be continuously turned on and disinfected when someone is indoors, and there are many types on the market, most of which use the principles of ultraviolet circulating air, photoelectric adsorption or photocatalyst.
2. Of course, there are also disinfection machines that use ozone disinfection, but no one should be indoors when using them.
3. Since the disinfection equipment is used, as long as it is used correctly, the bacteria and other pathogenic microorganisms in the workshop will be killed, so even if the bacteria are brought in (in fact, this is inevitable), it doesn't matter.
4. Selection of disinfection machine: If the power of the disinfection machine is small, the start-up time can be longer to achieve reliable disinfection effect.
-
The first is to hang an ozone generator high on the wall of the place that needs to be disinfected. This method is not ideal because the ozone gas cannot diffuse to distant locations or throughout the workshop.
At the same time, the ozone generator itself is surrounded by ozone gas, which can quickly be damaged. In general, this method cannot achieve the purpose of real disinfection, and is only suitable for those places with less strict disinfection requirements, and it is recommended not to use this method.
The second is to use the air duct of the air-conditioning system to diffuse ozone gas into the space for disinfection. A small open ozone generator can be placed inside the air duct, or the ozone generated by a closed ozone generator can be piped into the air duct. Although this method is simple, it requires a large amount of ozone, and it is possible to put ozone in a room that does not require ozone disinfection.
At the same time, ozone will corrode and damage equipment such as air ducts made of galvanized iron sheets and motors at the outlet of air ducts. In particular, when the ozone generator is installed inside the air duct, it is impossible to know whether the ozone generator is damaged, and it is not convenient to overhaul the ozone generator. If this method is limited due to certain conditions, it is recommended to use an external enclosed ozone generator.
The third is the use of Zhuhai silver and ozone company original"Duct spray? quot;。This method has the characteristics of simple installation, good disinfection effect, easy calculation of ozone dosing, and can be operated for specific rooms: ozone generator, Guangzhou ozone generator, Guangzhou disinfection machine.
The influence of ammonia cooler liquid level on the size of refrigeration capacity: 1The ammonia cooler has a high liquid level, a large heat exchange area between liquid ammonia and the process medium, but a small evaporation space and a small actual refrigeration capacity. >>>More
There is no shared area for villas, and the area occupied by the villa garden is on the land use right area on the real estate certificate. The contract between the buyer and the seller of the villa generally indicates: 1. The type of the commercial house is: >>>More
s r s = area.
r=radius. The length of the rectangle is equal to half the circumference of the circle. Namely. The width of the r rectangle is equal to the radius r of the circle. >>>More
The height of the scaffolding of the external wall of the building is calculated from the designed outdoor floor to the cornice (or the top of the parapet); The quantity of work is calculated according to the length of the outer edge line of the external wall (the wall stack with a protruding wall width greater than 240mm, etc., calculated according to the size shown in the figure and incorporated into the length of the external wall), multiplied by the height and calculated in square meters. >>>More
The floor area calculation value is specific and has a specific calculation method. >>>More