-
I only know**There is this standard.** Specifically, you go to buy a branch god to see it.**There is a standard network.
Standard number: GB T 50353-2005
Standard Name: Specification for Calculation of Construction Area of Construction Projects.
Standard Status: Active.
Date of implementation: July 1, 2005
Promulgating the department: Ministry of Construction of the People's Republic of China and General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China.
Brief introduction: This code is applicable to the area calculation of industrial and civil construction projects for new construction, expansion and reconstruction.
The scope of application of this code is the calculation of the construction area of newly-built, expanded and reconstructed industrial and civil construction projects, including the calculation of the construction area of industrial plants, warehouses, public buildings, residential buildings, buildings used in agricultural production, grain warehouses, subway stations, etc.
This code stipulates that the calculation of the construction area is calculated based on the outer edge line of the external wall structure above the leg, and the strangulation is a very short part of the wall root of the wall thickening, which cannot represent the entire external wall structure.
-
Yes, 2009 new rules for the calculation of quotas.
-
In fact, it is very easy, the full enclosure is calculated, and the semi-enclosed covered half is calculated. That's the principle. The only special thing in the building is the long corridor (full count).
-
3 0 24 The following items should not be counted as area: 8 Escalators, moving walks.
Explanation: Paragraph 8 escalator (inclined trail roller ladder), except for the two ends fixed on the floor slab or beam, the escalator itself is a piece of equipment, so the escalator should not be calculated for the construction area. Horizontal walkways (roller ladders) are equipment installed on the floor slab and should not be calculated separately.
From this point of view, I think that the escalator is not counted as an area, and its related wells should be calculated according to the shared space, that is, the area is not counted.
-
Don't count!
The following items should not be counted for area:
.8 Escalators, moving walks.
.It is clearly stated.
-
The standards and specifications provided by this ranxin netizen are very complete, but you must pay attention to the effectiveness of the standards and be sure to update them with the latest version.
-
"Code for Calculation of Construction Area of Construction Projects" GB T50353-2005 is a national standard specification, and Shanghai should also implement it, but Shanghai seems to have its own local specifications, which must be implemented with reference at the same time.
-
1 Foundations and foundations.
GB 50026-2007 Engineering Survey Code JGJ 79-2002 Technical Code for Building Foundation Treatment JGJ 120-99 Building Foundation Pit Support.
-
Design specifications, construction specifications, acceptance specifications. The country's requirements for construction are all-round, legally speaking, the main is the "Construction Law" and the "Contract Law", the next level has quality management regulations, safety management regulations, and then there are many norms, national, local, industry, and then there are more and more policy documents. These laws and norms are constantly being updated, and the policy provisions are temporal and regional.
-
Announcement No. 326 of the Ministry of Construction of the People's Republic of China Announcement on the issuance of the national standard "Code for the Calculation of the Construction Area of Construction Projects" The "Code for the Calculation of the Construction Area of Construction Projects" is hereby approved as the national standard, numbered GB T50353-2005, which will be implemented from July 1, 2005. This specification is organized by the Institute of Standards and Quotas of the Ministry of Construction and published by the China Planning Press. Ministry of Construction of the People's Republic of China April 15, 25.
Preamble to this paragraph. According to the requirements of the Ministry of Construction's "Notice on Printing and Distributing the Formulation and Revision Plan of National Standards for Engineering Construction in the Second and Four-Year Years" (Jianbiao [2004] No. 67), this specification is revised on the basis of the "National Unified Construction Project Budget Quantity Calculation Rules" issued by the Ministry of Construction in 1995. In order to meet the needs of the project cost valuation work, this code fully reflects the impact of new building structures and new technologies on the calculation of construction area in the revision process, considers the habits of building area calculation and international general practice, and coordinates with the relevant content of the "Residential Design Code" and the "Real Estate Survey Code". This specification has repeatedly solicited the opinions of relevant local and departmental experts and engineering and technical personnel, and has held many discussion meetings, and has been reviewed and finalized by experts.
The main content of this code includes general provisions, terminology, and provisions on calculating the construction area. In order to facilitate the accurate understanding and application of this code, the relevant provisions of the building area calculation code are explained.
-
Building codes: The minimum requirements for building safety, quality, and function proposed by the ** authorized body, and these requirements exist in the form of documents to form building codes, such as fire codes, building space codes, building modulus standards, etc.
There are more and more questions about the quality of commercial housing. As a national mandatory standard, it provides national mandatory standards for the quality of commercial housing and residential standards. As follows:
National Standards of the People's Republic of China.
Residential Building Code.
residential building codegb 50368—2005
Editor-in-chief Department: Ministry of Construction of the People's Republic of China Approval Department: Ministry of Construction of the People's Republic of China Implementation Date: March 1, 2006.
Ministry of Construction of the People's Republic of China.
Public Gazette No. 385.
The announcement of the Ministry of Construction on the issuance of the national standard "Code for Residential Buildings" hereby approves the "Code for Residential Buildings" as a national standard, numbered GB 50368-2005, effective from March 1, 2006. All provisions of this Code are mandatory and must be strictly enforced.
-
The building code is the lowest requirement for building safety, quality, function and other aspects put forward by the first authorized agency, and these requirements form the building code in the form of documents, such as fire code, building space code, building module standard, etc.
-
1.Temporary use of electricity.
Refer to the "Technical Code for Temporary Electricity Safety on the Construction Site" (JGJ46-2005). According to the actual situation, each branch shall prepare the organization design of electricity construction and design and plan for the construction of electricity. In terms of management, it focuses on controlling the erection of power lines and the management of operators.
2.High pier, cast-in-place beam support formwork.
Refer to the "Safety Technical Code for Building Construction Gantry Scaffolding" (JGJ128-2000), "Safety Technical Code for Fastener Steel Pipe Scaffolding in Building Construction" (JGJ166-2008), "Safety Technical Code for Building Construction Formwork" (JGJ162-2008), "Technical Code for Cast-in-Place Construction of Railway Concrete Beam Support Method" (TB10110-2011) (edited by China Railway Second Bureau, implemented on January 1, 2012) and so on.
3.Civilian ** items.
**According to the preliminary estimate of the excavated stone, the drug will be thousands of tons, hundreds of thousands of detonators, the safety risk is extremely high, and the transportation, storage, use and management are difficult. It is recommended to implement the domestic "Blasting Safety Regulations" (GB6722-2003) and the Ethiopian Regulations on the Management of Civil Explosives (in translation), etc., and adopt dual control measures, that is, China and Ethiopia should refer to them and strictly control them.
4.Large-scale, special equipment.
It is recommended to refer to the management regulations of China, because our department will use a large number of large machinery and equipment, the equipment use intensity is large, more scattered, and the risk level is very high, and the equipment management must be strictly controlled.
Referring to the "Regulations on the Safety Supervision of Special Equipment" and the "Regulations on the Safety Supervision and Administration of Construction Lifting Machinery" of the Ministry of Construction, it is required that all large-scale and special equipment entering the site must be inspected and registered, and the operators must be on duty. Measuring and tensioning equipment must be calibrated in accordance with Chinese regulations, and the inspection shall be confirmed by a qualified unit or an authoritative expert group. "Safety Regulations for Tower Cranes" (GB5144-2006) and "Safety Regulations for Construction Winches" (GB13329-91).
5.Edge protection.
Technical specifications for the safety of working at height.
6.Fire management.
The fire safety of flammable materials such as oil depots, camps and processing plants shall be managed with reference to local and Chinese laws and regulations. The fire safety management implements China's "Fire Protection Law" and "Fire Protection Regulations", and the fire protection technical standards refer to the "Code for the Configuration and Design of Building Fire Extinguishers" (GB 50140-2005) and the "Technical Code for Fire Safety at the Construction Site of Construction Projects" (GB50720-2011). Wait a minute.
-
Various quality acceptance specifications, construction technology disclosure.
-
As long as it is the current technical safety specifications.
5. Before concealing the concealed project, the construction unit shall notify the relevant units for acceptance, and shall form an acceptance. >>>More
Article 52 of the Constitution clearly stipulates that citizens of the People's Republic of China have the obligation to safeguard national unity and the unity of all ethnic groups in the country. The content of safeguarding national unity is that citizens must safeguard national sovereignty from being violated and safeguard national territory. >>>More
Plastering and scraping putty.
It is a process or step to treat the wall, and they can also make the wall more beautiful or stable. Some people think that plastering and putty scraping are the same type of thing, so it is natural to compare them and want to understand the difference between plastering and putty scraping before deciding to decorate on their own. >>>More
Educate yourself in advance so that you can easily learn it later. If you want to learn construction engineering technology, you must learn well, otherwise you won't do anything in this area, at most you will be a small contract foreman. It would be nice if you could get a national architectural qualification certificate, but it is not so easy to take the test, you need to work hard, after all, there will be a harvest if you work hard! >>>More
The next sub-project contract you do online, and then take a look for yourself, change the unit price, the scope of the contract, and the contracting method of the part of the agreement, and the general terms are applicable.