Beijing Fox Technology, professional gas mass flow controller, Beijing Fox Technology specializes in the production of thermal mass flow meters, thermal distributed mass flow meters and regulators and other products, the company adheres to scientific and technological support and world-class professionals, with advanced equipment, strict management, first-class service, to create a world-class brand.
-
It adopts a new design of mechanical vibration, impact and dirt resistance. Using the most advanced integrated circuit, the signal processing accuracy is high, the anti-interference is high, and the reliability is high. Extended-range models are available for superior small flow performance and extended flow range.
Capacitive flowmeter is optional, with good seismic performance and a maximum measurement temperature of 400. A submersible flow meter is available to allow for long-term immersion in water.
-
According to the Karman vortex street theory, the vortex flow meter is a kind of velocity flow meter made by using the natural vibration principle of the fluid and using the piezoelectric crystal or differential capacitor as the detection component.
Figres vortex flow sensors have many significant advantages, such as no moving parts, large measurement range, wide medium adaptability, high measurement accuracy, long verification cycle, long transmission signal distance, small pressure loss, simple structure, reliable operation, long service life, and convenient installation and maintenance. It can be widely used in petrochemical, metallurgical machinery, food, papermaking, as well as urban pipeline heating, water supply, gas and other industries of various liquids, gases, vapors and other single-phase fluids process measurement and energy-saving management.
-
1) Experimental pipeline, the device consists of 8 standard sensors with a diameter of DN = 50 150mm, and the parallel combination is compared with the detected large-diameter sensor (DN = 80 300mm). The test pipeline is arranged in parallel in the diagonal direction, the purpose of which is to save raw materials, reduce the cost, and just meet the requirements of the front straight section of various caliber sensors (according to the national standard ZBN12005-1989 or the procedure JJG643-1994) The standard sensor front straight pipe section is longer than 50DN; The straight pipe section in front of the detected sensor is longer than 20dn; Minimize drag loss.
2) The air source is supplied by two 9-19 high-pressure centrifugal fans and one LG300 200-1 roots blower. Two centrifuges of the same model can be operated in series or parallel according to the needs of the flow rate by controlling the electric valve to meet the requirements of different flow rates and different pressures.
3) Standard sensor: The device selects 8 standard sensors, all of which are stress vortex street sensors, the advantage of the instrument is that there are no moving parts, it has high repeatability, and has strong resistance to overload and impact. The stainless steel used for the sensor body is resistant to wear and corrosion, and the sensor is highly stable.
In addition, the instrument coefficient of this type of sensor is not or rarely affected by the physical parameters of the measured medium, so when used as a standard sensor, as long as it is basically the same as the measured material.
At present, the standard degree of gas vortex street sensor in China is generally at the level of grade 1, from the level of accuracy, it can not be used as a standard sensor, but the range of this kind of instrument is very wide, generally around 10:1 15:1, and the repeatability is very good, all are within, or even higher, such as the use of compression range in fixed-point calibration is an effective method to improve accuracy.
We have done a lot of experimental research work, and the results show that if the range is compressed to within 2:1 or 3:1, the requirements can be met in the fixed-point calibration, so it is feasible to use this sensor standard to establish a gas flow device.
When the water temperature sensor fails, the engine computer can't know the temperature of the engine water temperature, so he will keep the fan in a state of constant rotation to prevent the engine water temperature from rising [If there is a problem with the car, ask the car master. 4S shop professional technician, 10 minutes to solve. 】
Sewage cleaning flow sensor, comprise control reaction device, import anti-blocking device, impurity temporary storage device, outlet flow sensing device, shell, water inlet and water outlet, it is characterized in that described import anti-blocking device comprises two valves, filter screen, described impurity temporary storage device comprises a small pump, described impurity temporary storage device is connected to import anti-blocking device, interface is provided with valve, described outlet flow sensing device comprises flow rate sensing probe, flow rate sensing probe transmits signal to the control reaction device of system, Described control reaction device controls the operation of inlet anti-blocking device and magazine temporary storage device after receiving signal. >>>More
At present, the common air flow sensor can be divided into vane air flow meter and Carmen according to its structural type. >>>More
The dust concentration detector is mainly used to detect the dust concentration of the instrumentAccording to the different particle size of dust, it can be divided into detection, PM10 detection and TSP total dust detection;According to the requirements of the detection occasion, it can be divided into portable dust meter, explosion-proof dust meter and fixed installation dust meter. In construction sites and other construction fields, there are a lot of dust that looks very small, and although it does not look too dangerous, it cannot be ignored in some situationsFor example, in a confined environment, if the concentration of dust reaches the specified limit, it may cause immeasurable consequences to our economic security and life and health。Therefore, it is very important to use a dust concentration detector in the specified occasions. >>>More
The brake sensor has two functions, one is to light the brake light to warn the rear car to prevent rear-end collision, and the other is to provide signals for ABS anti-lock braking system, brake force distribution system, brake assist system, etc.