How to repair the Meiling floor fan if it doesn t turn, how to repair the floor fan if it doesn t tu

Updated on home 2024-06-11
19 answers
  1. Anonymous users2024-02-11

    Well, this depends on whether it is serious, if it is serious, you have to get it to the after-sales service center, if it is not serious, you can say that the screws are loose, and then for example, there are some small problems like this fan, these can try to get it.

  2. Anonymous users2024-02-10

    Meiling floor fan does not turn the tycoon, it may be a lack of lubricating oil, take the back cover apart, and add some lubricating oil to the bearing.

  3. Anonymous users2024-02-09

    How to repair the Meiling floor fan if it does not turn? If the motor is not broken, then you need to see if the capacitor is not well connected, otherwise the bearing is too greasy, and it can be repaired according to the fault by finding the fault.

  4. Anonymous users2024-02-08

    Meiling floor fan does not turn, you should let a professional repair master repair the chain in all parts of the country, don't worry.

  5. Anonymous users2024-02-07

    If Meiling's floor fan does not turn, you can go to a special repair shop to repair it.

  6. Anonymous users2024-02-06

    There are many possibilities for this fan not to rotate, there is no power supply, the power cord is broken, the switch is broken, the capacitor is broken, and the motor coil is broken.

  7. Anonymous users2024-02-05

    This is only a repaired motor, and it is OK to repair the motor.

  8. Anonymous users2024-02-04

    Meiling's is like how to repair if you don't turn around, don't repair it yourself, it's very dangerous, you have to find a professional to repair.

  9. Anonymous users2024-02-03

    Your good friend Meiling floor fan does not rotate how to repair it, it is a problem, or there is a problem with contact, so I will continue to hope to help you.

  10. Anonymous users2024-02-02

    Merrill Lynch landing order, no matter how you rest? This should be repaired by a professional fan repair place.

  11. Anonymous users2024-02-01

    How can Merrill Lynch rest if it doesn't turn when it lands on the mountain? Then you should find a professional after-sales service should be given to you.

  12. Anonymous users2024-01-31

    How to repair the Meiling floor fan if it doesn't turn, you can remove the shaft in the middle for him to replace.

  13. Anonymous users2024-01-30

    If it doesn't turn, it may be that there is a problem inside, or there is a problem with the battery in it, and you can disassemble it for repair.

  14. Anonymous users2024-01-29

    How to repair the Meiling floor fan if it does not turn? I don't think it's going to turn anymore, it's still the real machine that has a problem, you contact the manufacturer.

  15. Anonymous users2024-01-28

    First of all, make sure that the electricity enters the port fan normally. If you can't rotate or it is very heavy, the motor bearing is stuck, just add a drop of sewing oil. If you can easily turn your hand, turn on the fan and rotate the blades with a small stick.

    At this time, if the fan can rotate normally, it means that the starting capacitor is broken (the possibility of damage to the starting winding and wiring is not ruled out), just replace the capacitor. If you can't rotate it with manual help, you can only send it for repair.

  16. Anonymous users2024-01-27

    The repair method of the floor fan does not turn is as follows:

    1. In many cases, the reason why the fan blades do not rotate is the problem of poor maintenance. If the blade is stiff after turning off the power, you should use some lubricating oil to drip into the shaft so that it can be lubricated so as not to affect the motor to drag the blade.

    2. In view of the non-rotation of the fan blade caused by wear, the easiest thing is to replace the parts, especially the shaft sleeve, which is easy to burn off if it is worn out.

    3. If the capacitor capacity becomes smaller and the fan does not rotate, you can remove the capacitor and replace it with a new capacitor of the same model, it is recommended to choose a capacitor that is 20% larger than the original capacitor, which will have a better rotation effect.

    4. If the axial clearance of the rotating shaft is too large, you can choose to adjust the gasket after disassembling the motor. However, remember that when installing the motor back, you should pay attention to the rotor must be concentric with the bearing, slowly tighten the lubricating screws diagonally, and finally knock the shaft with a wooden handle to ensure that it is concentric.

    5. If it is because of electrical faults, you can check the wiring lines, sometimes the wires are damaged, etc., and the problem can be repaired.

  17. Anonymous users2024-01-26

    The repair method of the fan does not turn is as follows1. If it is confirmed that it is a socket problem, please plug the electric fan into another socket. If it is confirmed that the wire of the fan is broken, replace it with a wire of the same specification.

    2. First clean the oil and sludge of the fan motor, and then drip the lubricating oil on the rotating shaft. The lubricant can be a car lubricant or a sewing oil. You can consult the salesperson before purchasing, and it can be used for fan motors.

    3. If the thermal fuse or starter capacitor of the fan motor is damaged, you need to replace these two parts directly. It is possible to contact for a replacement or pay for the replacement within the warranty period.

  18. Anonymous users2024-01-25

    What's going on with Meiling air circulation fan not turning, hello, 1. It may be that the capacitor is damaged. Try to pluck the wind wheel with your hand, if you can run the side stool group, the capacitor is broken, and the capacitor needs to be replaced; If it still can't run, it is the motor bearing that is bitten, and the motor needs to be replaced. 2. The switch reed of the key loses its elasticity.

    Because the switch of the piano key has lost its elasticity, it has caused the phenomenon of poor contact of the piano key in the process of operating the orange, at this time the switch of the piano key must be replaced, and the exhaust fan can operate normally, I hope my answer will help you, <>

  19. Anonymous users2024-01-24

    Fans at home are prone to malfunction after being used for a long time. How to repair the floor fan if it doesn't turn? PChouse will take you to find out.

    1. Motor lubrication is not good: the priority is that the motor lubrication is not good, the shaft part should be lubricated with oil, the fan blade is installed on the motor can not be dragged, and after removal, the shaft can still run normally, which shows that the motor is not broken. How can you tell if you are short of oil?

    That is, after disconnecting the power supply, you gently dial the fan blade, and find that the rotation is a little stiff, which means that the oil is gone, and the rotation is very easy, indicating that the lubrication is good, and this is not turned for other reasons.

    2. Excessive motor loss: Secondly, you have to consider how long the electric fan has been used, the motor will be lost, and the shaft sleeve of the motor is easy to burn out after wearing. If the motor is used for a long time, the internal resistance of the motor will also become larger, and the load capacity will be lower, resulting in the inability to drive the fan blade to rotate.

    3. Motor overheating: motor overheating will also cause the motor to deteriorate with load capacity, and the active power of the motor will become low, resulting in the inability to drive the load.

    4. Short circuit of coil winding: From the inside of the motor, it has a protection device inside, and there is an overheating circuit breaker, that is, the coil winding part is short-circuited, resulting in a sharp increase in heat generation, and the circuit breaker is broken. This rarely happens.

    5. Capacitance capacity reduction: Another is that the starting capacitance capacity becomes smaller, although those parameters are written on the nameplate, but after a long time, the capacitance capacity will be reduced, resulting in the starting torque of the motor becoming smaller, unable to drive the load. This is simple, remove this capacitor, and then replace it with a new one, and the same model should be fine.

    But it's better to change to a 20% larger one than the original, and you will get better results.

Related questions
9 answers2024-06-11

You can check the plug to see if the line inside is broken, if the line is not broken, turn on the electric fan and then use the item to turn the fan blade to see if it moves, if it doesn't work, then take the electric fan apart, see if the power cord inside is broken, if it is not broken, then you can not deal with it for a long time, just find a repair home appliance OK!

19 answers2024-06-11

The rear wheel of the battery car can be rotated when it is idle, but it cannot be rotated when it lands because: >>>More

8 answers2024-06-11

Reason]: 1. After using the electric fan for a long time, we must first see whether the motor lubricating oil is still there, if the motor lubrication is not good, there will generally be noise, and the more serious thing is that the fan does not rotate. In the event of a power outage, if you pull the fan blades with your hands, the fan will also be a little stiff. >>>More

10 answers2024-06-11

The solution to the Ford Focus car fan not turning: check whether the relay of the fan is in working condition, if the relay does not work, it is a fault state, and you need to replace the relay in time to solve the problem that the fan does not rotate. >>>More

7 answers2024-06-11

It is safer for the fan to pay for a new one, and it will be scrapped if it is not good to dismantle it yourself.