How to install hot and cold water pipes in the bathroom? My family didn't know it at first, and I regretted it after moving in.
When decorating a house, water and electricity are very worthy of our attention. Water and electricity are inextricably linked to our lives. Water is the source of life, and electricity gives life to the world.
When we renovate a new house, wires and water pipes are the top priority, and the laying of wires and the installation of water pipes have to go through strict requirements. If there is a problem due to negligence, the consequences are very serious, and we have to pay attention to it. How to install hot and cold water pipes in the bathroom?
My family didn't know it at first, and I regretted it after moving in.
In general, the wires are inside the wall and are not subject to any external impact. And now the inside of the wire is also relatively safe, so the wire generally does not need to worry too much. But water is different, when we install hot and cold water pipes, we must pay attention to it, and we must not install it wrong.
If it is installed incorrectly, it is easy to have an accident by alternating hot and cold water, and it is very troublesome to repair, and there will be big problems.
When many people install electrical appliances, they usually install a water heater in order to make it more convenient to use water. And I'm sure many people will experience this situation with me. When we were using water, the hot water suddenly turned into cold water.
In fact, at this time, the cause of the problem is the problem of hot and cold water pipes. Most of the installers install the hot and cold water pipes in the same tank, so that the hot water cannot come out, and even if the hot water comes out, it usually becomes cold water. The reason for this is that the hot and cold water pipes are not separated, and the two streams may collide, and when the pressure of the cold water is greater than the hot water, the hot water will be reopened.
And when there is a problem with the water at home, if you do not have professional knowledge, you must find a professional worker to repair it, and do not do it yourself, so as to avoid greater trouble. When we install hot and cold water pipes, it is best to put them in two slots, so that the use of hot and cold water will not be affected. And it's best to keep the hot and cold water pipes farther away, so that you don't have to worry about the hot water turning into cold water.
We can also wrap a layer of insulation material on the hot water pipe, which is also useful.
Also, once there is a problem with the water pipe at home, you must pay attention to the connection of the water pipe. You have to get the connection out in order and make it smooth. Otherwise, there will be a big problem when using it, even after the water pipe is remedied, the water pipe must be fixed and not let loose.
These are actually small details, just a moment's attention, we should deal with it.
-
Find a professional plumber installer to help you make the open pipe.
-
The hot and cold water pipes are not connected to the bathroom, which is not done well when it is renovated, so the decoration company can only be re-constructed.
-
The hot water pipe is not connected to the bathroom, and it costs too much to reconnect, so I recommend buying a heater and putting it in the bathroom, so that the bathroom can have hot water available, and buying a water heater to install in the bathroom can be said to be the most simple and rude solution to the problem of no hot water in the bathroom.
-
If you want to make an ideal, you need a plumber to do it again, and the simple thing is to ask a plumber to do the open pipe, so that you can solve the problem that the hot and cold water pipes and toilets are not connected.
-
Find the closest distance to the hot and cold water source and lay the open pipe. Of course, you can also re-groove the laying.
-
You can design a connection between the hot and cold water from the nearest place and the bathroom, and you can turn it on.
-
If your bathroom only has cold water pipes and no hot water pipes, and you want to install a bathroom cabinet, you can consider:
1.Choose the right bathroom cabinet: First of all, you need to choose a bathroom cabinet that does not need to use hot water pipes, so that it will not be affected by the lack of hot water pipes.
Generally speaking, bathroom cabinets on the market usually need a drain connection, so you need to make sure that there is a drain in the bathroom.
2.Add hot water pipes: If you want to install shower facilities in your bathroom, then consider adding hot water pipes.
You need to find a professional plumber to help you deal with this, including installing and connecting equipment such as water heaters. Specifically, you need to install the water heater near the toilet and connect the hot and cold water pipes before connecting the shower facilities.
3.Install an electric water heater: If it's difficult to add hot water pipes or you don't need much hot water, consider installing an electric water heater.
The electric water heater can be used separately and only needs to be plugged in, so there is no need for additional hot water pipes, which is more convenient. However, it should be noted that due to its power limitations, the water use time and temperature need to be controlled when using.
The only thing to remind you is that if you do not know how to install water and electricity or are not familiar with the operation, please be sure to seek professional help to ensure safe and correct use.
-
Hello dear! Glad for your question! The intermediate pipe connection of the hot water return water in the cold section of the bathroom; How to install hot and cold water pipes in the bathroom?
1. In the design of pipe laying drawings, to determine the requirements, we can start laying pipes. 2. The first step is to find the cold and hot water pipes of the main valve to close, and the inlet of the cold and hot water pipes is connected to the main valve to facilitate the overall management. 3. Then you need to lay the pipe according to the predetermined drawing, and then connect the cold water pipe to the cold water pipe.
4. When installing heat pipes, the water inlet and outlet of the water heater should be distinguished. The water inlet is connected to the main valve, and the water outlet is connected to the toilet pipe. After the installation is completed, first open the valve to make sure that there is no leakage, etc., and finally install the faucet and shower in the bathroom.
What are the installation precautions for hot and cold water pipes in the bathroom: 1. When the two pipes overlap, the winding pipe must be used. 2. When installing the water heater inlet and outlet, the position of the water inlet valve and the air inlet valve must be considered and installed in the corresponding position.
3. The PP-R pipeline shall not be used as a pull-climbing, hanger, etc. 4. The position of the pipe clamp and the slope of the pipeline should meet the specifications and requirements. All kinds of valves are installed in the correct position and flat installation, which is easy to use and maintain.
5. The cold and hot water pipes are generally into the wall, and the depth of the slotting needs to be carefully checked when slotting, and the cold and hot water pipes cannot be in the same tank. 6. The hot and cold water pipes in the bathroom should be separated from each other and not too close to each other. The outlets of cold and hot water are kept horizontal, generally hot on the left and cool on the right.
And the height of the shower pipe is more reasonable. 7. For the installation of hot and cold water pipes in the bathroom, the water pipes generally go to the top and do not go to the ground, and the pipeline laying needs to be horizontal and straight, avoiding bending, leaving room for later maintenance. The layout direction should be safe and reasonable, as far away from the circuit as possible, to avoid potential water leakage hazards.
-
Reinstall. Installation of hot and cold water pipes:
1.The hot and cold water pipes in the bathroom should be separated and not too close together. The height of the shower water pipe is between.
2.The installation of toilet water pipes, the general water pipes go to the top and do not go to the ground, the cold and hot water outlets must be horizontal, generally the left is hot and the right is cool, the pipeline laying needs to be horizontal and straight, and the layout direction should be safe and reasonable. The position of the pipe clamp and the slope of the pipe should meet the requirements of the specification.
All kinds of valves should be installed in the correct and flat position, which is easy to use and maintain.
3.The cold and hot water pipes are all into the wall, and the depth of the tank needs to be checked when slotting, and the cold and hot water pipes cannot be the same tank.
4.When installing the water heater inlet and outlet, the water inlet valve and the air inlet valve must be considered and installed in the corresponding position.
-
Summary. Kiss! Generally, the left side of the bathroom is a hot water pipe, and the right side is a cold water pipe, and the red line above the pipe indicates that it is connected to hot water, while the blue line represents it is connected to cold water. When installing, you must pay attention to the distinction, because the cold water pipe cannot replace the hot water pipe, but the hot water pipe can indeed replace the cold water pipe.
Kiss! Generally, the left side of the bathroom is a hot water pipe, and the right side of the oden cavity is a cold water pipe, and the red line on the empty morning of the pipe indicates that it is connected to hot water, and the blue line is connected to cold water. When installing, you must pay attention to the distinction, because the cold water pipe cannot replace the hot water pipe, but the hot water pipe can indeed replace the cold water pipe.
1. When installing hot and cold water pipes, the first thing to pay attention to is that the installation method must be correct in order to be able to play a good role in changing its performance, after all, there is a certain demand for water. 2. When installing hot and cold water pipes, you should also pay attention to planning first, and the best thing is to draw a drawing, so that the installation will be faster and you don't need to test it many times.
3. The installation of hot and cold water pipes also requires a certain amount of technical content, so you also need to find a professional master to deal with it when installing, and do not install it indiscriminately. 4. At the same time, it is also necessary to pay attention to the installation of water pipe parts, and the parts must be tightened, so that the Zhenming stove will not affect its later use. 5. When choosing a water pipe, you should also pay attention to the quality of the water pipe, because the water pipe is used under water immersion for a long time, and it is inevitable that there will be rust.
In the process of later use, it is also necessary to do a good job of cleaning to make it last longer. 6. In addition, we should also pay attention to the time of installation, if it is installed in the community, we must say hello to the property and avoid installation on rest days or holidays, which will cause some trouble to neighbors, so this link also needs to pay special attention.
-
Kiss! Hello, happy to answer your <>
It is usually caused by the valve on the tap water inlet line not being opened, the filter is blocked, or the hot water outlet pipe is blocked. In this case, the things that need to be done are: 1. Confirm whether the tap water inlet valve is open; 2. Generally speaking, this situation is mostly seen in hot and cold water faucets, where the hot water is blocked, and the possibility of blocking with filter slag is the greatest.
Remove the filter and check valve on the tap water inlet pipeline and clean it and install it back; 3. Close the water inlet valve, drain all the impurities and dirt that may exist in the water pipe, and then rinse it with tap water and drain the water. If there is hot water in the cold water pipe at home, generally, after the water pipe is stopped, the hot water in the solar energy will flow back to the cold water pipe, and it is recommended to find a master to check the direction of the water pipe. The measures we should take ourselves before the master comes are as follows:
1. Pay attention to the installation of the pipeline, which is not the wheel of the hot and cold water pipes in series; 2. If the pipeline is connected in series, check the necessary valves on the pipeline and close the valves. 3. Finally, it is recommended to install a check valve at the position of the solar water inlet to prevent water backflow. How can I avoid such problems?
1. Technicians said that when adding water to a solar water heater, you must avoid the peak period of water consumption. 2. In addition, if the one-way valve is not installed or has been damaged, it should be installed and replaced in time. 3. At the same time, for this phenomenon, the majority of owners in the community must pay attention to it, because the water supply main network in the community is a hot melt pipe, and the heating capacity is limited.
Hope mine can help you <>
Do you have any other questions?
-
Hello Kiss is happy to answer this question for you. Is there such hot water in the cold water pipe: The reasons why the hot water from the bucket electric water heater flows into the cold water pipe are as follows:
1 The water inlet in the water heater is not a check valve, or the check valve is broken, and the water can be discharged from the water inlet. 2. The water level of the hot water source in the water heater is too high, and the cold water expands after being heated, and the volume becomes larger, and the pressure generated is greater than the pressure in the cold water pipe. 3 There is less cold water in the cold water pipe, the pressure is low, and the hot water is pressed over.
4. The frottling device of the hot and cold water outlet switch is broken, resulting in the cold water pipe and the hot water pipe being connected, and the pressure of the hot water is higher than the pressure of the cold water, and the hot water will naturally be left in the cold water pipe.
-
Summary. Hello, here is the installation tutorial.
Installation specifications and precautions for hot and cold water pipes:
Within the specified cooling time, the freshly welded joint can also be corrected, and a small amount of rotation can be made, but after the cooling time, it is strictly forbidden to forcibly calibrate. Note: The connected pipes and fittings should not be tilted, and they should be basically horizontal and vertical, so as to avoid the wrong angle when installing the faucet and not being installed normally.
During the specified cooling time, it is strictly forbidden to let the freshly machined joints be subjected to external force.
When using PP-R fittings with metal threads, the white raw meal tape must be securely sealed to avoid water leakage from the threads. As shown in the figure below;
When over-tightening PP-R pipe fittings with metal threads, water leakage may occur due to cracking of the pipe fittings, so pay attention to appropriate force.
It should be fixed with a professional pipe clamp, and must not be hooked to prevent damage to the water pipe and reduce the life of the water pipe. The spacing between cold water pipe clamps is 50 5cm, and the spacing between hot water pipe clamps is 35 5cm.
The direction of the water pipe should be horizontal and vertical (under the premise that the slotting is horizontal and vertical), and avoid hardpulling or twisting the water pipe, causing the water outlet to be not parallel to the wall, which will affect the appearance and the installation of the mixing faucet.
0. Is the pipe connected to the cold water and hot water installed on the pipe of the cold water heater dismantled?
Hello, happy to answer for you, please provide your question correctly so that you can give you the correct answer.
Hello, this is the installation tutorial hot and cold water pipe installation specifications and precautions: Within the specified cooling time, the newly welded joint can also be corrected, and a small amount of rotation can be made, but after the cooling time, it is strictly forbidden to forcibly calibrate. Note:
The connected pipes and fittings should not be tilted, and they should be basically horizontal and vertical, so as to avoid the wrong angle and normal installation when installing the faucet. During the specified cooling time, it is strictly forbidden to let the freshly machined joints be subjected to external force. When using PP-R fittings with metal threads, the white raw meal tape must be securely sealed to avoid water leakage from the threads.
As shown in the figure below; When over-tightening the PP-R pipe fittings with metal threads, there may be cracking pipe fittings resulting in water leakage, and attention should be paid to moderate force It should be fixed with a professional pipe clamp, and no hook nails should be used to prevent damage to the water pipe and reduce the life of the water pipe. The spacing between cold water pipe clamps is 50 5cm, and the spacing between hot water pipe clamps is 35 5cm. The direction of the water pipe should be horizontal and vertical (under the premise that the slotting is horizontal and vertical), and avoid deadlifting or twisting the water pipe, causing the water outlet to be not parallel to the wall, which will affect the appearance and the installation of the mixing faucet.
The current toilet sewer pipes.
There are two situations, one is caisson type, and the sewer pipe is not on the roof downstairs, and the other is directly on the roof. If there is water seepage downstairs, it may be your sewer pipe or water seepage from the edge of the sewer pipe. If the seepage water seeps down the edge of the sewer pipe, it will be troublesome and will have to be re-waterproofed. >>>More
Hello: The water pipes in the bathroom at home use plastic materials with better corrosion resistance, because plastic materials are less likely to be corroded, while metal materials will rust after a long time of use, and slowly corroded! >>>More
1. Coat the adjusted AB glue in the leaking place, and then wrap a layer of ribbon on it, so that the ribbon is soaked with AB glue and then coat a layer of AB glue on the ribbon, the whole process can be divided into two or many times, 2. Use the "plugging king" bag powder. Mix it with water and wrap it in the leakage, and it will dry in a while, and the effect is very good. Dry quickly, prepare before construction. >>>More
Under normal circumstances, the bathroom and the kitchen cannot share a sewer pipe, because the water discharged from the bathroom belongs to boiling water, and the smell is relatively pungent, it will be easy to have nausea, if the bathroom and the kitchen share a sewer pipe, it will be easy to block. Under normal circumstances, the water in the kitchen is relatively clean, and it can be reused after treatment, so in the process of decoration, it is best not to choose to combine the kitchen sewer pipe with the bathroom sewer pipe. And this situation is also not in accordance with the regulations, the sewage in the bathroom needs to be discharged into the septic tank, and the wastewater in the kitchen needs to be discharged into the grease trap. >>>More
You can take a long cable and pass it through the wall to connect the kitchen to the bathroom. This doesn't look messy and solves the hot water problem.