Modern air conditioners are all produced by our company, all domestic markets, they cooperate with our company and authorize us to produce them with full authority. Hehe, we are also a large-scale air conditioning company, rest assured.
There are several possibilities for the failure of the outdoor unit:
1. The outdoor capillary or connecting pipe is blocked, so that the system can not return oil normally, and the oil (oil return, oil output is the professional term of our air conditioning industry, that is, the refrigerant direction), resulting in excessive pressure and thermal protection of the compressor, so it jumps, and after the compressor stops, the temperature drops down, and the compressor starts automatically (generally about 3 minutes), and so on. So the compressor starts and stops frequently;
2. If the outdoor temperature probe is damaged, the outdoor ambient temperature cannot be felt, so the indoor electronic control board will report an E2 fault and the system is abnormal; However, in this case, the compressor will not start frequently, which can be ruled out;
3. There is no refrigerant in the system, that is, there is no refrigerant in the whole system, so the effect of refrigeration cannot be achieved. If your air conditioner has only been used for 2 or 3 years, the normal machine does not have the reason for too little refrigerant, which proves that the indoor and outdoor connecting pipes or capillary leakage refrigerant, if you have not used the outdoor unit personally, this situation will not occur if you use it normally, which proves that this is the quality problem and design problem of the product itself, which belongs to the responsibility of the manufacturer, and has nothing to do with the user, directly find the manufacturer's customer service maintenance or complain to 315!
4. Pay attention to whether the outdoor fan is running when running, if it is running normally, then ignore it, if it is not running, it means that the outdoor motor is faulty, and it may not be powered on or blocked.
-
It may be that the temperature sensor of the inner tube is broken, so try to replace it.
-
1. You can put it behind the door and blow it obliquely (45 degree angle), because the sun is setting at the door, and it shouldn't be very hot inside.
2, cabinet air conditioning is a kind of split air conditioning, commonly used in families and small offices, cabinet air conditioning has the advantages of high power, strong wind, etc., the starting point is relatively higher, usually suitable for a larger area of the room, is to buy hanging air conditioning or cabinet air conditioning needs to be determined according to the actual needs of the user, such as the living room area is small to buy a desk hanging air conditioner can be coped, of course, if the living room area is large, it is best to buy cabinet air conditioning.
-
Depending on your situation, you can put it behind the door and blow it diagonally (at a 45-degree angle), because the sun is setting at the door, and it shouldn't be very hot inside. I hope my answer will help you.
-
Generally, the cabinet is placed next to the door of the store or not in the middle of the back, you can put it in the corner next to the door of the store.
-
It's best to keep it as far away from the door as possible, so that it doesn't waste air conditioning or electricity. Put too close to the door. The air conditioner will be digested by the hot air outside the door.
So put it as far away from the door as possible. It can well retain the dispersion of cold air. Just pick a corner, too.
The corner that you don't walk around often is best.
-
Put it behind the door and blow it in, it does not take up space, the position is not conspicuous, and the use efficiency is also high.
-
If you can install an external unit behind the store, you may wish to install it at the back of the store, for the following reasons:
The external unit does not need to bask in the sun (energy saving), and the pipeline is also short;
The position occupied by the internal machine is not as obstructive as the position in front of the store.
-
Put in the vents.
Air conditioning on the windows outside the door.
Heating under it. It can intercept the hot and cold air from outside.
-
12 meters long, according to the ratio of 1:**, put it at the place of meters at the door.
-
Yes, you can take a look at Haier**.
-
There are 2P's for basically every brand.
-
What happens is that the drain pipe of the air conditioner is not good, and the drain pipe will slack or bend after aging, resulting in poor drainage. In addition, it is necessary to check whether the drain pipe of the air conditioner is blocked by dirt, which prevents the condensate from draining.
In addition, if the installation is not in place, the air conditioner four-wall vents are not smoothly connected and sealed, which will also cause dripping and a series of other problems.
-
The main reasons for dripping water in the air conditioner are as follows:
1.The VTH unit is offset.
There are three main reasons for the deviation of the indoor unit: the installation of the indoor unit is not firm, the installation of the fixed hanging plate of the indoor unit is not firm, and the installation of the indoor unit is not horizontal at the beginning and is slightly tilted. With the slight vibration of the internal unit during the operation of the air conditioner, in the case of the first two points, the internal unit is easy to shift after a long time, resulting in a high position on the side of the drainage pipe, resulting in difficulty in drainage; When the horizontal position of the indoor unit is improperly installed, when the horizontal position of the indoor unit is installed and tilted, the direction of the pipe intersection is too high, resulting in the obstruction of the discharge of condensation.
Solution: Move the air conditioner inside, recalibrate the position of the air conditioner with a liquid level, and trim or lower the end of the condensate pipe outlet of the air conditioner as much as possible.
2.Poor drainage.
Due to the aging of the drain pipe, it is loose or bent into a wave shape, resulting in poor drainage, which is also easy to cause the phenomenon of dripping water in the air conditioner. Secondly, the air-conditioning holes reserved in the house often attract birds and rats to nest and build nests, which will cause damage to the drainage pipe, resulting in poor drainage or damage to the drainage pipe, and condensation water will flow inward along the drainage pipe from the hole to cause dripping.
Solution: Contact the after-sales service of the store, the air conditioning manufacturer or a qualified repairer to replace the drainage pipe during the three-warranty period. Of course, if you know the relevant technology, you can also buy an ordinary PVC thin pipe and install it yourself, but most people live in buildings nowadays, and the construction of outdoor units is dangerous.
3.Condensation on the piping.
Because the insulation material on the pipe is too poor or too thin, or not completely encapsulated, when the refrigerant passes through the pipe, it causes condensation, just like some water droplets always condense on the outside of a cold beer.
Solution: First of all, you should disassemble the adhesive tape to check whether the insulation material is aged or installed properly, if you find a gap or a thin phenomenon, you can rewrap it. At the same time, the aging adhesive tape can be replaced to maintain the tightness of the copper pipe.
4.The drain pipe is blocked.
The drain pipe leading out of the exterior is artificially blocked or the drain is blocked by stolen goods, so that the condensation cannot be discharged.
Solution: This situation usually occurs in the south with a lot of smoke, if the building is designed with drainage pipes, it is necessary to focus on checking whether the drainage pipes are unblocked, and whether the drainage pipes and air conditioning pipe inlets are properly connected. If the drainage pipe is installed by direct dripping, the possibility of the drainage pipe being blocked by dust is greater, and the drainage pipe can be flushed with a high-pressure water gun or tool to achieve the purpose of dredging.
5.The heat exchanger drips.
When we find that the water of the air conditioner is present in large quantities and drips from the blades of the heat exchanger, that is, the indoor unit, it is usually that the heat exchanger is too dirty, and it can be rinsed with a commercially available cleaning agent, gently brushed with a wool brush, or used a high-power electric hair dryer to cool off the dust. Of course, if you find that the air conditioner is not refrigerated, it may also be that the heat exchanger temperature is uneven due to insufficient refrigerant, which can be measured through the pressure gauge.
-
Installation problems, when the indoor unit is installed, the connecting pipe joint is not bandaged, and there will be frost if the copper is exposed, and water will be generated when the indoor unit is exposed, so there will be water in the lower part of the indoor unit.
-
1;The drain is too high, 2 the drain is clogged 3;Lack of water means that the pipe insulation is damaged or not done well.
-
Hello, the first is that the drain pipe is blocked, and the second is that the inside of the drain pipe is higher than the outside, and the water can't flow out, so it flows indoors.
-
1. The condensate pipe is damaged.
2. The outside of the condensate pipe is blocked.
3. The connection of the condensate pipe interface is not tightened.
4. The water tray of the air conditioner condenser is damaged.
-
The size of the external machine is not easy to find, it is recommended that you go directly to the shopping mall, ask the brand door to door, which one has your right size of the 3 HP machine, so you have to choose it.
-
Chigo has a model that is relatively small.
But I don't know exactly how big you are.
How big a machine do you need in your living room.
Put your living room space and the location of the outside machine space down.
I'll help you with your reference.
90 almost, it's really not good, consider Haier Gree has a small foreign machine.
-
A: No, you cannot.
If the air conditioner needs to be inhaled during the working process, usually the air inlet is under the cabinet, and if the air inlet is blocked, it will definitely reflect the effect. Even if other failures occur, the maintenance personnel must first ask you to remove the shield in front of the air inlet before making a judgment.
The refrigeration capacity of cabinet air conditioners is relatively large, and the air volume is also large, of course, the working noise is also relatively large, and it also occupies a certain space, which is suitable for use in larger rooms. >>>More
The disassembly and assembly of the air conditioner is a more professional problem, if it leads to the leakage of refrigerant (that is, the refrigerant you said), it cannot be used normally if it is installed again! It's best to find a professional. >>>More
The dripping water of the internal machine has little to do with this, [check whether the drainage pipe drainage is normal] [check whether the unit is deficient in fluorine] [check whether the heat exchanger plate of the internal machine is dirty and blocked] I hope it will be useful to you.
Duct machine. It is also called air duct air conditioning. >>>More
There are many reasons for air conditioner leakage, and you can make a general judgment based on different leakage locations. >>>More