The wall hung gas stove is on the first floor Why is the floor heating on the third floor not hot?

Updated on home 2024-08-10
12 answers
  1. Anonymous users2024-02-15

    This should be hot water not up. Causes the ground to not be hot.

    It is recommended that you install a circulating pump to increase the pressure of the water, it is recommended to use a 25-8 circulating pump.

    1. Wall-hung boiler.

    head. Generally, the wall-hung boiler is operated by a single pump, with a head of about 10 meters (the circulation of three floors is a bit difficult). If the three floors of underfloor heating are shorter per circuit (water separator.

    Relatively more) can overcome the shortcomings of a single pump, but these problems may be ignored in general design and construction. At present, individual gas furnace manufacturers have launched high-power, double-water pump products (German products: Warm Heart Beibei), which effectively solves the problem of insufficient head of three-layer heating, with one pump supplying water and one pump returning water.

    In addition: the ordinary gas furnace is pressed by 1-kg, if the third floor is heated, the working pressure should also be appropriately increased, which is conducive to circulation.

    2. The power of the gas furnace. According to 100 watts per square meter, it is enough, for example, the construction area is 260 square meters, 260 * 100 = = 26 kilowatts. If the power is insufficient, it will also affect the end heating. Check this against the nameplate on the side of the stove.

    Whether it is a lack of power. The power range of conventional wall-hung boilers is 16-30 kilowatts.

  2. Anonymous users2024-02-14

    The gas wall-hung boiler is on the first floor, and the floor heating on the third floor is not warm, which should be considered from several aspects, and there may be air in the floor heating, which makes the circulation in the floor heating not good. It is also possible that the water pressure of the wall-hung boiler is not enough, and you need to add water to it. It is also possible that the wall-hung boiler is too small to carry such a large area.

  3. Anonymous users2024-02-13

    There are two situations, the first is that the floor heating is broken, the second is blocked, no matter which case, it is the best choice to find a professional maintenance master to repair it.

  4. Anonymous users2024-02-12

    The head of the wall-hung boiler. If the power is insufficient, it will also affect the end heating, double water pump products (German products, high-end gassing. Other than that.

    5-1. The power of the gas furnace, such as the construction area of 260 square meters. According to 100 watts per square meter is sufficient, but generally designed. 8. It effectively solves the problem of insufficient head of three-layer heating.

    If you compare the nameplate on the side of the stove yourself, you may ignore these problems during construction. At the highest end of the pipeline is prone to gas storage: warm heart Beibei), a pump for water supply.

    Generally, the wall-hung boiler is a single pump operation, which needs to pay attention to three problems, the head is about 10 meters (the three-story circulation is a bit difficult), and the working pressure should also be appropriately adjusted to hinder the water circulation.

    2, 1, deflation is a necessary step. The water separator has a bleed valve. If the three layers of underfloor heating are shorter per circuit (with a relatively large number of water separators), the shortcomings of a single pump can be overcome.

    Whether the power is insufficient, 260 * 100 = = 26 kilowatts. The power range of conventional wall-hung boilers is 16-30 kilowatts. Now individual gas furnace manufacturers are launching high power.

    3. One pump for water return. 5 kg: The ordinary gas furnace works with a pressure of 1-1, if the third floor is heated, it is conducive to circulation: follow-up.

  5. Anonymous users2024-02-11

    Wall-mounted floor heating on the 1st floor, 3rd floor floor heating is not hot? It's not because of location. In the final analysis, there are two aspects of the heating problem, one is the temperature of less water, and the other is the pressure of circulation.

    If the boiling water temperature is fine, it should be a plumbing problem. That is, the pressure of the inlet pipe is insufficient. You can add a small pump to the inlet pipe.

  6. Anonymous users2024-02-10

    The wall-hung boiler is on the first floor, and the reason why the third floor is not hot may be that the heat cannot be reached, and the heat cannot be reached, or it may be that there is gas in the radiator on the third floor.

  7. Anonymous users2024-02-09

    Due to underfloor heating, it is based on the principle of heating the ground by circulating hot water. Therefore, if the pipe is blocked due to scale, or if the valve is closed by mistake and no circulation is formed, the normal heating of the floor heating will not be hot. So you should check two aspects, the first is whether the gas heating is normal, whether the water is heated normally, and the second is whether there is hot water in the pipe to form a circulation.

  8. Anonymous users2024-02-08

    Floor heating on the first floor radiator on the second floor, the first floor is not hot, what is the matter with the heat on the second floor.

    Kiss. The floor heating on the first floor is not hot, and the heating on the second floor is hot, indicating that the heating system circulates well on the second floor, and the first floor cannot circulate normally in the heat source pipe network. Floor heating and radiators are mixed in one system, because the hot water temperature required for heating is high, the hot water temperature required for floor heating cannot exceed 60 degrees, and the heating and floor heating need to be coupled to balance the water temperature and pressure.

    Therefore, the duplex floor is equipped with radiators and floor heating, the construction technical requirements are relatively high, and the temperature will be uneven if the operation is not good, and the system pressure balance needs to be paid attention to during construction, and the water supply temperature is different upstairs and downstairs, and the hot water supply is circulated. Solution: 1. Turn off the radiator on the second floor, let the system on the first floor heat first, and then turn on the radiator on the second floor.

    2. Open half of the radiator valve on the second floor, and install an external water pump (water mixing device) on the first floor to increase the circulation speed of floor heating on the first floor. 3. Add water mixing system and decoupling tank.

  9. Anonymous users2024-02-07

    This boiler of yours is really amazing, you can use a three-story house, the boiler has a power size, buy a boiler on the 3rd floor and install it, a boiler ** three floors should not be enough.

  10. Anonymous users2024-02-06

    There was a problem with the floor heating system, and a circulating pump should have been added to the floor heating at that time.

  11. Anonymous users2024-02-05

    The temperature requirements of the outlet water of the floor heating and the radiator are different, and the mixed installation like this generally requires the addition of a mixed water mixing system, or your installation method is different.

  12. Anonymous users2024-02-04

    There can be a variety of reasons why the 2nd floor of the wall-hung boiler floor heating is not hot, and here are some common solutions::

    1.Check the operating status of the wall-hung boiler: it may be that the wall-hung boiler has insufficient gas**, the burner is blocked, or the gas pipeline is faulty, which causes insufficient heating. Professional technicians can be called in for inspection and repair.

    2.Check the floor heating pipes: The wide and vertical pipes of the floor heating system may have problems such as water leakage, blockage, or local failure, resulting in insufficient heating. Professional technicians can be called in to inspect and repair the underfloor heating system.

    3.Check the cleanliness of the radiators and the flow of water: If the pipes of the underfloor heating system are unobstructed, but the heating is not working well, it may be because the radiators have too much dirt, heavy limescale, or insufficient water flow. Cleaning and flow regulation are possible.

    4.Check the insulation on the second floor: The second floor may have problems such as poor insulation or air leakage from doors and windows, resulting in poor heating results. It is possible to strengthen the insulation and adjust the tightness of the doors and windows.

    As mentioned above, if the second floor of the wall-hung boiler floor heating is not hot, it is necessary to carry out systematic inspection and maintenance first, find out the problem, and then make targeted adjustments. If you can't solve the problem yourself, you can ask a professional technician to deal with it.

Related questions
9 answers2024-08-10

Technical principle and characteristics of straw gas furnace. >>>More

17 answers2024-08-10

Flowers that don't live at home need to be burned to about 16 degrees in a gas stove, which is very suitable for the living environment of flowers.

19 answers2024-08-10

When we decorate the bathroom, we will consider using the toilet or squatting toilet, in fact, if the bathroom is larger, you can consider the toilet, although the toilet has many disadvantages, but the toilet is a tool that can make it easy for us to go to the toilet. There are many types of toilets, and wall-hung toilets are favored by many families because they are suspended and will be more convenient to clean and clean. So how much punch does a wall-hung toilet have? >>>More

14 answers2024-08-10

Hello, I'm glad to answer for you, and I'm sorting out the answer for you One Horse is totally fine. >>>More

10 answers2024-08-10

Installation:

The installation of the piped fresh air system is large, which needs to be carried out simultaneously with the house decoration, and the installation of the wall has not been treated and the ceiling has not been completed. The main machine and the pipeline are hidden and installed in the ceiling, and when doing water and electricity, it is necessary to contact the engineer to check the installation environment, communicate the pipe layout plan, and the installation location of the equipment. >>>More