Phenolic insulation board is divided into B1 grade and composite A grade.
A-grade phenolic composite board is about 2200 yuan cubic meter.
B1 grade phenolic board is around 1800.
-
This is divided into product types, now there are two kinds on the market, one is molded, one is the assembly line, the quality of the assembly line is better, ** will be more expensive, depending on how much bulk density you want, Jilin Xuelong Taida phenolic board factory production line, ** is about 1,000.
-
Phenolic insulation board is made of thermosetting phenolic resin foaming, which has excellent fire resistance, heat insulation, sound insulation, light weight and energy saving properties, heat resistance, flame retardant self-extinguishing, flame penetration resistance, no dripping in case of fire and flame retardancy to prevent the spread of flames.
This mainly depends on the density and specifications of the product, the 40 kg of mold foaming is about 400 yuan, and the ** of the assembly line is slightly more expensive. Specifically**You can consult: Langfang Shunying insulation.
-
The first place is different, and it is also divided into bulk weight, Jilin Xuelong Taida Phenolic Board Factory produces assembly line plates, and the 50kg bulk density is about 1200.
-
The continuous line is about 1400, and the mold is about 650, so it is necessary to consult Xinxiang Hongfu anti-corrosion and thermal insulation 0373-2681348
-
Phenolic insulation board** is determined by density, process and board thickness, depending on what specification you use.
-
The phenolic fireproof insulation board is affected by many factors. For example, density, production process, fire rating, etc., I don't know which one you are talking about? About phenolic fireproof insulation board**Here are detailed instructions, you can find out for yourself first.
-
Phenolic insulation board is made of phenolic foam, phenolic foam is a new type of non-combustible, fireproof and low-smoke insulation material, which is a closed-cell rigid foam made of phenolic resin with foaming agent, curing agent and other additives.
Phenolic insulation board is made of phenolic foam, phenolic foam is a new type of non-combustible, fireproof and low-smoke insulation material, which is a closed-cell rigid foam made of phenolic resin with foaming agent, curing agent and other additives. Its most prominent features are non-combustible, low smoke, and resistance to high temperature discrepancy. It overcomes the shortcomings of the original foam plastic insulation material that is flammable, smokey, and deformed when heated, and retains the characteristics of the original foam plastic insulation material such as light weight and convenient construction.
Advantages of phenolic insulation board over other insulation materials:
1. The difference between phenolic insulation board and polyurethane insulation material.
Phenolic fiber insulation board is non-flammable and non-toxic, but although polyurethane has good thermal insulation performance, it is flammable and produces toxic gases.
2. The difference between phenolic insulation board and rock wool and glass wool.
Rock wool and glass wool pollute the environment, and it is easy to breed bacteria, the water absorption rate is also high, and the use time is short, but the phenolic insulation board is different, the phenolic insulation board is made of environmentally friendly materials, and it will not breed bacteria, and the life span is up to 30 years without deformation, and the thermal insulation performance is good.
3. Compare the difference between polystyrene foam.
The defects of polystyrene are that it is easy to burn when exposed to fire, shrink after a long time, and have poor thermal insulation performance. The phenolic insulation board has a uniform closed-cell structure, low thermal conductivity, good thermal insulation performance, comparable to polyurethane, and better than polystyrene foam.
-
1. Start from the supporting part from bottom to top, use polymer sticking mortar to paste the phenolic insulation board on the wall. The bonding area should be greater than 35%, and the first layer should be greater than 50%. If the outer sheath is heavier, 4-6 insulation nails should be nailed per square meter.
2. After bonding, it should be stopped for 24 hours before the protective layer construction. 3. The construction of the external application surface can be carried out every 24 hours. 4. The thickness and density of the insulation board should not be less than 4cm in the north of the Yellow River according to the design requirements, and the density should be 50kg m, and the cold area should be thickened.
Composite insulation decorative board in one building insulation and decoration.
-
What are the characteristics of phenolic insulation board? Phenolic resin insulation board is made of phenolic foam resin, phenolic foam resin is a new type of non-combustible, fireproof and low-smoke insulation material, which is a closed-cell rigid foam made of phenolic resin with foaming agent, curing agent and other additives. Its most prominent features are non-combustible, low smoke, and resistance to high temperature discrepancy.
It overcomes the shortcomings of the original foam plastic insulation material that is flammable, smokey and deformed when heated, and retains the characteristics of the original foam plastic insulation material such as light weight and convenient construction.
Phenolic foam resin insulation board has good thermal insulation performance, and its thermal conductivity is about, which is far lower than the inorganic and organic exterior wall insulation products commonly used in the market, and can achieve higher energy-saving effects.
The use of excellent fire performance insulation layer phenolic foam, and other materials for building insulation, can basically reach the national fire standard A, fundamentally eliminate the possibility of external insulation fire, the use of temperature range of -250 +150.
How to identify the quality of phenolic insulation board].
1.The production is produced by large foam, and the product produced by this method is relatively low in density, easy to be brittle, and easy to appear pulverized or slag.
2.The other is the assembly line production, which is to make a warm plate for modified phenolic protection, which is to improve its phenolic resin and foaming process, and produce a modified phenolic insulation board to overcome the shortcomings of its own pulverized slag to a certain extent, so that the density of the modified phenolic insulation board is generally more than 55kg. 3.
In addition to the above methods of identification, we can also observe the appearance of the phenolic insulation board, press the density by hand, break it to see the toughness of the insulation board, and rub it by hand to determine the quality of the exterior wall phenolic insulation board.
4.In addition, when buying insulation boards, you must choose regular manufacturers to buy, because such regular manufacturers, the products they produce are controlled by strict quality supervision departments. The quality problems of the products produced by such regular manufacturers are relatively rare.
Phenolic insulation board meets the standard and is welcomed by the market
It is understood that phenolic foam board is made of phenolic foam board made of phenol and formaldehyde condensation polymers mixed with other additives, and Japan's building insulation system has been made of phenolic foam board packaging machine.
Fortunately, the composite phenolic foam board developed by most domestic enterprises has been tested by the National Center for Quality Supervision and Inspection of Fireproof Building Materials, and its combustion performance has reached GB8624A. This shows that as a safe, green new energy-saving building material, the advantages of phenolic foam board have been recognized by the construction department and the public security and fire department.
In 2009, the Ministry of Public Security and the Ministry of Housing and Urban-Rural Development jointly formulated the Interim Regulations on Fire Prevention of External Thermal Insulation Systems and Exterior Wall Decorations of Civil Buildings, which requires that "the combustion performance of external thermal insulation materials in civil buildings should be Class A and should not be lower than Class B2"; In 2011, the Fire Bureau of the Ministry of Public Security issued a "Notice on Further Clarifying the Relevant Requirements for the Fire Supervision and Management of External Thermal Insulation Materials in Civil Buildings", requiring that "the standard for the use of external wall insulation materials in civil buildings shall not be lower than Class A", in order to cut off the soil for fire breeding from the root.
-
This needs to be discussed in detail.
-
1 All main parameters:
Project performance indicators.
Apparent density (kg m3) 60
Thermal conductivity (average temperature 25) [w (m k)] Volume water absorption %
Combustion performance class B
Compressive strength (kpa) 100
Dimensional stability % 40 ,7d
70℃,7d ≤
130℃,7d ≤
-
Specifications:
Thermal conductivity: tensile strength:
Performance density: 》=60
Oxygen index: 45-48
Burn height: 30
Smoke density class: 4
In addition to the tensile strength, other indicators are very good, and it is an excellent choice for the new generation of insulation materials.
-
The construction method of phenolic insulation board is as follows:
1) Treatment of the base wall: the surface of the base wall shall not have pollutants such as oil, release agent, floating dust, etc., the uneven part of the wall can be polished with an angle grinder, and the protrusions on the surface of the wall 10mm should be removed.
2) Wall elastic line: hanging vertical, sleeve, elastic thickness control line: at the side wall, roof according to the insulation thickness requirements of the plastering control line.
3) Phenolic insulation board installation.
1) The size of the standard board is 1200*600, the diagonal error is less than 2, and the extruded board is cut with a heating wire cutter or tool knife, and the allowable deviation of the size is .
2) After the extruded plastic board is glued and installed on the wall, ensure its flatness, squeeze tightly between the board and the board, and there shall be no seams.
3) The installation of extruded plastic board should be paved horizontally along the horizontal direction from bottom to top, and each row of boards should be staggered 1 2 board length, and the minimum local staggered seam should not be less than 100.
4) Install the fixings:
1) Fixture installation. According to the position of the design requirements, drill with a percussion drill, the hole diameter is 10, the depth of drilling into the base wall is about 60, and the depth of the fixing piece anchored into the base wall is about 50 to ensure firm and reliable.
2) The number of fixing parts is set according to the requirements of the design description.
3) The self-tapping screws should be squeezed tightly and the surface of the engineering plastic expansion nail cap and the extruded plastic board should be neatly or slightly screwed into some to ensure that the tail of the expansion nail is screwed back to make it fully anchored with the base wall.
-
The construction method of phenolic insulation board includes:
1. The paste of phenolic board should be carried out from bottom to top, and the wind force should not be greater than level 5 during construction, and protective measures should be taken for construction in the rainy season.
2. When pasting phenolic boards, if the wall is dry, it should be watered and moistened for construction.
3. The bonded phenolic board should be vertically staggered, the length of the staggered seam should not be less than 1 2 of the width of the plate, the seam between the plates should be tight, and the width of the plate should not be greater.
4. Except for the corner of the wall, it is strictly forbidden to apply glue at the joint part of the board and the board, and the excess glue should be removed in time after each board is bonded.
5. The corners of the doors and windows should be cut out of the holes with a whole phenolic board, and they should not be spliced.
6. At the edge of the insulation layer, the whole phenolic board should be bonded, and the small board should not be spliced.
7. In case of protruding pipelines and embedded parts, the whole phenolic plate should be sleeved and anastomized, and the non-whole plate should not be spliced.
8. When it is necessary to use phenolic boards of non-standard specifications, small hand saws should be used for cutting and processing.
9. The self-tapping screws should be squeezed tightly and the surface of the engineering plastic expansion nail cap and the phenolic plate should be neatly or slightly screwed into some to ensure that the tail of the expansion nail is screwed back to make it fully anchored with the base wall.
-
1. This construction method is only used in the construction of the phenolic plastering external insulation project in the region.
2. This construction method is only applicable to the construction of external thermal insulation projects in the Northeast region.
3. The implementation of construction personnel and tools, material performance, operating procedures and quality standards should not only comply with this construction plan, but also comply with the relevant provisions in the "Technical Regulations for Phenolic Board Composite Walls with Sintered Bricks" DB23 T700 and the "Heilongjiang Province Construction and Installation Engineering Construction Technical Operation Regulations for Masonry Engineering" DB23 T706 in Chapter VI "Phenolic Board Thin Plastering External Wall External Insulation Engineering".
4. The construction of the external insulation project should be carried out only after the acceptance of the base wall project.
5. The fixing of the phenolic board thin plastering external insulation system and the main structure should be fixed by combining sticky nails.
2. Construction conditions.
1. The working environment of construction operation and the ambient temperature above 48 hours after completion should be higher than 5, and construction is strictly prohibited in windy and rainy days.
2. Before the start of the external insulation project, all the door and window frames, various entrance pipelines and other wall embedded parts of the external wall should be installed and accepted. The size of the gap between the door and window frame and the wall should meet the requirements of the thickness of the insulation layer.
3 The construction surface should avoid direct sunlight, if necessary, set up a sunscreen cloth on the scaffold to cover the construction wall, the scaffold should use double row of external scaffolding, and the minimum distance between the scaffold and the wall should not be less than 400.
4. The wall screed should be scraped flat with a scraper, and then compacted with a pull plate. The quality of the screed should meet the intermediate plastering quality standards.
-
The insulation of the internal and external walls of the phenolic insulation board is generally made of mortar bonding method or sticky nail combination method 1, starting from the supporting part from bottom to top, and the phenolic insulation board is pasted on the wall with polymer sticking mortar. The bonding area should be greater than 35%, and the first layer should be greater than 50%. If the outer sheath is heavier, 4-6 insulation nails should be nailed per square meter.
2. After bonding, it should be stopped for 24 hours before the protective layer construction.
3. The construction of the external application surface can be carried out every 24 hours.
4. The thickness and density of the insulation board should not be less than 4cm in the north of the Yellow River according to the design requirements, and the density should be 50kg m, and the cold area should be thickened. Composite insulation decorative board in one building insulation and decoration.
1. Factory production. The phenolic insulation board is firmly bonded to the decorative panel.
Second, the use of light steel keel construction scheme, the composite insulation decorative board hanging on the keel, to be fixed.
3. Be sure to deal with the gaps between the plates to prevent water leakage.
Non-transparent curtain walls can be bonded to the inner panels of the curtain wall or bonded to the wall. An enclosed space is formed between the curtain wall panels.
The fireproof isolation belt shall be carried out by sticking nails according to the spacing required by the design, and shall not be less than 30 cm.
Special note: Newly produced phenolic boards are generally not ready for use until 21 days after curing.
At present, the most energy-saving insulation materials used in China are polystyrene boards, part-molded polystyrene boards (commonly known as "polystyrene boards") and extruded polystyrene boards (commonly known as "extruded boards") and cement polystyrene boards. >>>More
Yes, it is for anchoring, not nailing! Flat roofs are generally not required to nail insulation nails on the roof of the roof. >>>More
First of all, it is necessary to understand the production principle of floor heating extruded plastic board: extruded plastic board is also a recyclable and environmentally friendly material, which is made of high-quality plastic particles added with flame retardant and foaming agent extruded by high pressure and high temperature; There is no volatilization of any toxic gas in the production process; >>>More
Wujiang Zhongzheng Steel Structure Purification Color Plate has long been committed to the development and manufacturing of air purification products and the development and production of color steel plates, and provides design, manufacturing, installation and commissioning one-stop services for large-area clean workshops, steel structure buildings, color steel activity houses, etc. Welcome to inquire and negotiate.
AEPS insulation board is made in ordinaryPolystyreneThe granules are the main raw materials, and the polystyrene raw materials are preheated and foamed into the particles, and then mixed with organic fireproof materials and mixed with the film, and addedFoam boardThe equipment is heated for secondary foaming molding, and the product achieves A-level non-combustible effectThermal conductivityIt has the characteristics of low, fireproof, waterproof, light weight and high strength, and is a substitute for various insulation materials. >>>More