Hello, vertical air conditioner cleaning method:
2. Cut off the power supply and open the host panel. The action should be slow and light, because many plastic products are easy to damage. Some air conditioner hang-up panels have a button at the top, so be careful not to break. The air conditioner cabinet is divided into an inner panel and an outer panel, and pay attention to the wires connected when removing the cabinet panel.
3. Remove the filter. The air conditioner hangs up and gently pulls out the filter directly. Some cabinet filters are on the outer panel, which can be removed, and some models are fixed with screws, which need to be paid attention to.
4. If the fin is dirty, you can use a special cleaning agent to rinse the large particles, and do not use a hard brush, otherwise the fin will be damaged. If large particles are not obvious, ignore this step.
5. Spray the perfect air conditioner foam cleaner on the fins, shake well before spraying to form pressure, spray at an oblique angle of 20 degrees, and spray several times according to the degree of dirtiness of the air conditioner. The dirtier the air conditioner, the darker the foam will become, generally brown, and the dirtier it will turn black. Wait about fifteen minutes after spraying.
6. Wait for the gap to clean the filter screen and wipe the panel with a special cleaning agent.
7. After the foam is decomposed, the fins can be rinsed with a watering can depending on the degree of pollution, and this step can be ignored if it is not dirty. If it is a cabinet unit, it can be equipped with a flush sink.
8. Reset the filter screen, be sure to install it in place, and prevent it from lifting. Reset the panel. If it is a cabinet, the bottom of the cabinet can be scrubbed clean before the panel is reset.
9. Turn on the power and restart the machine for 30 minutes to ensure that the dirty water is completely drained from the drain. To avoid spraying the detergent, start by covering the exhaust vent with a towel for about 10 minutes.
The cleaning of the vertical air conditioner is much simpler than the hanging air conditioner, and it can be done by yourself, so if the vertical air conditioner at home is dirty, you don't need to ask others for help.
-
1. Turn off the power, open the host panel, and remove the filter for cleaning.
2. If the fins are dirty, they can be rinsed with cleaning agent, not brushed with a brush, so as not to damage the fins.
3. Then wipe the dust inside the body with water, and the dust on the surface of the air fan should also be brushed clean.
4. After the inside and outside are cleaned, install the filter back.
-
Vertical air conditioner cleaning is very important, not only to ensure its long-term use effect, but also to prolong its service life, and at the same time to prevent some unnecessary failures. The following are the methods and steps of vertical air conditioner cleaning.
1.Clear the filter and panel.
First, turn on the aircon panel, remove the filter, and use a vacuum cleaner or brush to remove dust and sediment from the filter. If you find that the filter is very dirty or damaged, you can replace it with a new one. After many times of use, the filter will become covered with impurities, dust and other dirt, it is recommended to clean or replace it regularly to ensure the performance and safe operation of the air conditioner.
2.Clean the air outlet and radiator.
Locate your air conditioner's air outlets and radiators, and use a brush to remove dust, sputum, and impurities that have accumulated in them. You can use a compressed air tank to clean the fine dust and debris scattered in the details such as electronic devices, air conditioning condensation plates, fan blades, etc., which are placed vertically in a delicate manner.
3.Clean the heat exchanger.
Professional air conditioning cleaning service personnel will use professional cleaning equipment, tools and efficient cleaning agents to thoroughly clean the grease, scale and mold in key parts such as heat exchangers and wind turbines. If you don't have these tools, it's best to have a professional clean them to ensure thoroughness.
4.Removes odor problems.
Isotung cavity odor is a common problem of household air conditioners, especially if the air conditioner holes, basins, drainage pipes and other parts are not cleaned for a long time, it is easy to breed bacteria and produce unpleasant odors. To solve this problem, you can use a professional cleaning agent to thoroughly clean the inside of the air conditioner and eliminate odors.
In conclusion, regular cleaning of a vertical air conditioner is an important step to ensure its proper functioning. If you are not sure how to clean and maintain, you can consult a professional air conditioner to call a cleaning service personnel for cleaning and maintenance.
-
Cleaning method: Here is an example of the cabinet of Gree air conditioner.
1. Find the place where the air conditioner filter is removed, pick the cover that covers the screws, and open the cover with the filter inserted.
2. Use a Phillips to take out the two screws, it is recommended to use a screwdriver with a magnet head, so that the screws are easy to take out and not easy to fall.
3. Remove the cover plate with the filter screen and pull out the filter screen inserted in it.
4. You can see that the filter screen is covered with more dust, which needs to be cleaned, for the effect or health of the air conditioner, it is recommended to clean it regularly.
5. Use a brush to remove the dust first. Then rinse it with laundry detergent and finally rinse it off with clean water.
6. After the cleaning is completed, it looks much cleaner. Take it to the balcony to dry.
7. Wait for the filter to be clean, then plug it back in.
8. Cover the air conditioner back, use a screw driver to return the screw, and cover the screw cover. Get.
Cut off the power supply, unplug the power supply, and turn off the air conditioner. How to clean the filter of Haier vertical air conditioner and remove the front panel of the air conditioner. Unscrew the screws with a screwdriver to remove the front panel of the air conditioner. >>>More
1. First of all, turn off the power supply of the air conditioner. This is very important, and electrical appliances must pay attention to safety. >>>More
Put a sealed trap on the outlet pipe, then install a bottom hole at the bottom of the outdoor unit, and then connect a small pipe to the outlet pipe as needed. Once the pipes are connected, it's time to drain the water. When installing the air conditioner drain pipe, first we need to put the sealing ring on the drain pipe, and then install the outdoor unit in the ventilated place, and rotate the outdoor unit drain pipe about 90 degrees. >>>More
Adjust the proper temperature to save power. The higher the temperature in the summer, the cooler the temperature in the winter. >>>More
Put a sealed trap on the outlet pipe, then install a bottom hole at the bottom of the outdoor unit, and then connect a small pipe to the outlet pipe as needed. Once the pipes are connected, it's time to drain the water. When installing the air conditioner drain pipe, first we need to put the sealing ring on the drain pipe, and then install the outdoor unit in the ventilated place, and rotate the outdoor unit drain pipe about 90 degrees. >>>More