How to install the air conditioner drain pipe, how to install the vertical air conditioner drain pip

Updated on society 2024-06-28
8 answers
  1. Anonymous users2024-02-12

    Put a sealed trap on the outlet pipe, then install a bottom hole at the bottom of the outdoor unit, and then connect a small pipe to the outlet pipe as needed. Once the pipes are connected, it's time to drain the water. When installing the air conditioner drain pipe, first we need to put the sealing ring on the drain pipe, and then install the outdoor unit in the ventilated place, and rotate the outdoor unit drain pipe about 90 degrees.

    A pipe is connected to the outlet to drain the sewage from the outdoor unit. After the pipe connection is completed, we need to do a hydrostatic test. When installing the air conditioning drain pipe, be sure to ensure the height of the drain pipe to facilitate the discharge of sewage.

    Try to choose an angle with a slope so that the drain pipe does not rise or the sewage cannot drain out. Otherwise, once the condensate from the indoor unit flows back into the air conditioner, the air conditioner will be damaged, and even the air conditioner will be soaked in water. Be sure to ask a professional to help us install the drain pipe of the air conditioner, because we don't know much about the installation of the air conditioner, so don't be careless when installing the drain pipe.

    Try to choose a drain pipe of the same brand, and don't buy an inferior one.

  2. Anonymous users2024-02-11

    The drainage groove of the indoor unit is in the middle, about 1 meter higher than the ground, when installing the air conditioner, the wall hole can almost be discharged as long as it is not 30 cm above the ground, but the actual operation can only be low and not high, and the hole will be higher in special circumstances!

    The most reasonable position should be parallel to or slightly lower than the hole behind the air conditioner! Because the air conditioner is used for a long time, the drain pipe will discharge a small amount of dust (mud), if the wall hole is high, the dust will stay in the distance between the inner unit and the wall hole, and it will cause blockage for a long time, causing the internal unit to leak!

  3. Anonymous users2024-02-10

    The air conditioner drain pipe replacement process is as follows:Tools Raw materials: Haier air conditioner, air conditioner H6, waterproof glue.

    1. Generally, the air conditioning duct should be bandaged and the thick pipe with the white umbilical cord should be removed.

    2. Look at this threaded pipe, it's a drain pipe. Suspicious of Punzhou.

    3. Pull out the drain pipe from the joint.

    4. Connect the new tube as before, it is best to wrap tape around the connection.

    5. If the damaged area is very small, then wrap it tightly with a little PVC waterproof tape.

    6. Wrap the pipes and wires with tape in the original way and reinstall them. Celery.

  4. Anonymous users2024-02-09

    The principle of drainage pipe installation: slope, reasonable pipe diameter, nearby discharge (simply summarized as one slope, two pipes and three nearby principles).

    First, the installation points:

    The slope of the drain pipe is not less than 1 100.

    Horizontal drains must avoid hedging to avoid backslopes and poor drainage.

    A vent should be provided at the highest point of the drain pipe to ensure the smooth discharge of condensate, and the exhaust port must be facing down to prevent dirt from entering the pipeline.

    After the pipeline connection is completed, the water test and full water test should be done to check whether the drainage is smooth on the one hand, and check whether the pipeline system is leaking on the other hand.

    The joints of the insulation material must be bonded with special glue, and then wrapped with rubber and plastic tape, the width of the rubber and plastic tape is not less than 50mm, to ensure firmness, to prevent condensation.

    The drain pipe of the air conditioner must be installed separately from other sewage pipes, rainwater pipes and drainage pipes in the building.

    Indoor units with different drainage forms cannot share the same centralized drainage pipe.

    Hanger spacing: usually horizontal pipes, risers, each riser should not be less than two, too large horizontal pipe spacing will produce deflection and air resistance.

    The static pressure value is relatively large, and the natural drainage indoor unit must be made a trap to avoid negative pressure during operation, resulting in poor drainage or blowing water out of the air outlet.

  5. Anonymous users2024-02-08

    **Too blurry to see clearly, if the water pipe is a joint, find the drainage pipe joint of the cabinet to connect to the guide outside, if the pipe is connected to the cabinet at one end, lengthen a section with the copper pipe to guide the outdoor line.

  6. Anonymous users2024-02-07

    Steps. First, do a good job of measurement; Steps.

    Second, then do a good job of thermal insulation; Steps.

    3. Then install the exhaust pipe; Steps.

    Fourth, after the connection to the sewage pipeline. The detailed steps are as follows. Steps.

    First, in the decision to install the air conditioning drainage pipe place, pay attention to the slope of the slope, do not install at will, to measure whether the angle of the installation of the air conditioning drainage pipe will form the situation of high inside and low outside, if the opposite is easy to have diversion problems, so at the beginning of the measurement, it is necessary to ensure that the water pipe joint is higher than the height of the main pipe. Steps.

    2. Before the installation of the air-conditioning drainage pipe, the air-conditioning drainage pipe should be insulated, so that it will not cause condensation on the outside of the pipeline, otherwise it is easy to damage the ceiling, so it is necessary to use insulation cotton to do a good job in the insulation task of the air-conditioning drainage pipe. Steps.

    3. When installing the exhaust port, an exhaust port should be installed at a place of 15 meters each, and an exhaust port should be installed on the drainage pipe, so as to ensure that the parts of the drainage pipe installed by the air conditioner are smoother. Steps.

    Fourth, when starting the formal installation, you need to use professional equipment to install, at this time, you should also pay attention to whether the interface of the drainage pipe is installed correctly, and also pay attention to whether the drainage pipe drain port enters the vicinity of the pipeline that can discharge water, so as to prevent the drainage pipe from being able to drain smoothly due to air backflow, affecting the later life, it is recommended to hand it over to a professional master for arrangement.

  7. Anonymous users2024-02-06

    1.Determine the location of the drain pipe: First of all, you need to determine the location of the drain pipe of the air conditioner, generally speaking, the drain pipe needs to extend from the back or bottom of the air conditioner, and then connect to the drain pipe.

    2.Prepare the drain pipe: The drain pipe can use PVC pipe or PE pipe, and choose the appropriate pipe material and pipe diameter according to your needs. In general, the diameter of the drain pipe should match the drain of the air conditioner to ensure smooth drainage.

    3.Install the drain pipe: Connect the drain pipe to the drain wide opening of the air conditioner, and then extend the drain pipe to the drain pipe. If desired, pipe clamps or tape can be used to secure the drain to the wall or floor.

    4.Test the drain: After the installation is completed, you need to test whether the drain is unblocked.

    You can pour some water into the air conditioner's tank and see if the drain is able to drain properly. If the drainage is not smooth, you need to check whether the drain pipe is blocked or bent.

  8. Anonymous users2024-02-05

    1.First, determine the location of the water outlet of the air conditioner drain pipe, which is generally on the indoor wall or floor.

    2.Punch holes at the outlets, and the size should match the diameter of the drain pipe.

    3.Insert the drain into the outlet, making sure that the plug into the deep world is properly held and not too shallow or too deep.

    4.Lay the drain along the wall or floor, taking care not to bend or twist to avoid affecting the drainage.

    5.If the drain needs to pass through a wall or floor, a special wall sleeve or floor sleeve can be used to ensure that the perforation is sealed.

    6.Finally, place the end of the drain pipe on a suitable drain or drain device to ensure that the drain is unobstructed.

Related questions
8 answers2024-06-28

1. Wrap the insulation pipe:

Before the renovation, the drainage pipe is covered with insulation pipes (there are various specifications on the market, thick foam pipes), and then the hanging shed and decorative pipes. >>>More

12 answers2024-06-28

1.longitudinal and transverse drainage and permeability of highways; 2.Vertical and horizontal drainage of the back of various retaining walls and side ditches of highways; 3. >>>More

14 answers2024-06-28

First, the water pipe in the machine is damaged. Second, the installation of the indoor unit is unqualified, and the pipe outlet is too high.

10 answers2024-06-28

Reasonable selection of drainage pipes is a very important part of home design, and it is also the most important part of drainage system design. Roughly speaking, it is mainly considered from three aspects: economy, situation and technology. Many people are at a loss when choosing the material of the drain pipe. >>>More

7 answers2024-06-28

After the home decoration is completed, there are often some materials that are not used, throw away and feel a little wasteful, after all, it is also purchased with the decoration budget, we are human witty, good at thinking, often have some good thinking, make ideas works, today we want to ** is to use a pvc pipe to make dozens of good-looking furniture, maybe you will say useless, to show you another form of coffee table made in this way: >>>More