How to install the air conditioner drain pipe, how to install the vertical air conditioner drain pip

Updated on home 2024-06-28
7 answers
  1. Anonymous users2024-02-12

    Put a sealed trap on the outlet pipe, then install a bottom hole at the bottom of the outdoor unit, and then connect a small pipe to the outlet pipe as needed. Once the pipes are connected, it's time to drain the water. When installing the air conditioner drain pipe, first we need to put the sealing ring on the drain pipe, and then install the outdoor unit in the ventilated place, and rotate the outdoor unit drain pipe about 90 degrees.

    A pipe is connected to the outlet to drain the sewage from the outdoor unit. After the pipe connection is completed, we need to do a hydrostatic test. When installing the air conditioning drain pipe, be sure to ensure the height of the drain pipe to facilitate the discharge of sewage.

    Try to choose an angle with a slope so that the drain pipe does not rise or the sewage cannot drain out. Otherwise, once the condensate from the indoor unit flows back into the air conditioner, the air conditioner will be damaged, and even the air conditioner will be soaked in water. Be sure to ask a professional to help us install the drain pipe of the air conditioner, because we don't know much about the installation of the air conditioner, so don't be careless when installing the drain pipe.

    Try to choose a drain pipe of the same brand, and don't buy an inferior one.

  2. Anonymous users2024-02-11

    <> When installing the drain pipe of the air conditioner, first of all, the thick pipe wrapped with tape is removed, and the drain pipe can be seen.

    There are some details that need to be paid attention to when installing the air conditioner drain, that is, the exhaust port should be arranged, and the attention should be paid to installing an exhaust hole every 10 meters away from the drain pipe. Installing exhaust holes on the drain pipe can eliminate abnormal noises and make the air conditioner drainage system smoother.

    This answer is applicable to most brands of air conditioners such as Gree, Midea, and Haier.

  3. Anonymous users2024-02-10

    The drainage groove of the indoor unit is in the middle, about 1 meter higher than the ground, when installing the air conditioner, the wall hole can almost be discharged as long as it is not 30 cm above the ground, but the actual operation can only be low and not high, and the hole will be higher in special circumstances!

    The most reasonable position should be parallel to or slightly lower than the hole behind the air conditioner! Because the air conditioner is used for a long time, the drain pipe will discharge a small amount of dust (mud), if the wall hole is high, the dust will stay in the distance between the inner unit and the wall hole, and it will cause blockage for a long time, causing the internal unit to leak!

  4. Anonymous users2024-02-09

    The principle of drainage pipe installation: slope, reasonable pipe diameter, nearby discharge (simply summarized as one slope, two pipes and three nearby principles).

    First, the installation points:

    The slope of the drain pipe is not less than 1 100.

    Horizontal drains must avoid hedging to avoid backslopes and poor drainage.

    A vent should be provided at the highest point of the drain pipe to ensure the smooth discharge of condensate, and the exhaust port must be facing down to prevent dirt from entering the pipeline.

    After the pipeline connection is completed, the water test and full water test should be done to check whether the drainage is smooth on the one hand, and check whether the pipeline system is leaking on the other hand.

    The joints of the insulation material must be bonded with special glue, and then wrapped with rubber and plastic tape, the width of the rubber and plastic tape is not less than 50mm, to ensure firmness, to prevent condensation.

    The drain pipe of the air conditioner must be installed separately from other sewage pipes, rainwater pipes and drainage pipes in the building.

    Indoor units with different drainage forms cannot share the same centralized drainage pipe.

    Hanger spacing: usually horizontal pipes, risers, each riser should not be less than two, too large horizontal pipe spacing will produce deflection and air resistance.

    The static pressure value is relatively large, and the natural drainage indoor unit must be made a trap to avoid negative pressure during operation, resulting in poor drainage or blowing water out of the air outlet.

  5. Anonymous users2024-02-08

    **Too blurry to see clearly, if the water pipe is a joint, find the drainage pipe joint of the cabinet to connect to the guide outside, if the pipe is connected to the cabinet at one end, lengthen a section with the copper pipe to guide the outdoor line.

  6. Anonymous users2024-02-07

    Steps. First, do a good job of measurement; Steps.

    Second, then do a good job of thermal insulation; Steps.

    3. Then install the exhaust pipe; Steps.

    Fourth, after the connection to the sewage pipeline. The detailed steps are as follows. Steps.

    First, in the decision to install the air conditioning drainage pipe place, pay attention to the slope of the slope, do not install at will, to measure whether the angle of the installation of the air conditioning drainage pipe will form the situation of high inside and low outside, if the opposite is easy to have diversion problems, so at the beginning of the measurement, it is necessary to ensure that the water pipe joint is higher than the height of the main pipe. Steps.

    2. Before the installation of the air-conditioning drainage pipe, the air-conditioning drainage pipe should be insulated, so that it will not cause condensation on the outside of the pipeline, otherwise it is easy to damage the ceiling, so it is necessary to use insulation cotton to do a good job in the insulation task of the air-conditioning drainage pipe. Steps.

    3. When installing the exhaust port, an exhaust port should be installed at a place of 15 meters each, and an exhaust port should be installed on the drainage pipe, so as to ensure that the parts of the drainage pipe installed by the air conditioner are smoother. Steps.

    Fourth, when starting the formal installation, you need to use professional equipment to install, at this time, you should also pay attention to whether the interface of the drainage pipe is installed correctly, and also pay attention to whether the drainage pipe drain port enters the vicinity of the pipeline that can discharge water, so as to prevent the drainage pipe from being able to drain smoothly due to air backflow, affecting the later life, it is recommended to hand it over to a professional master for arrangement.

  7. Anonymous users2024-02-06

    There are four main steps: First, preliminarily determine the location of the drainage pipe according to the installation location of the air conditioner. Second, ask a professional to install the drain pipe and fix it.

    Third, install a drain at the location of the drain. Fourth, after installation, check whether the drainage pipe is installed correctly, whether there is water leakage, and the installation is completed if no problem is found.

    Note that the installation of air conditioning drain pipes requires professional skills, and if there is any deviation, it may affect the use effect of the air conditioner before it collapses, so it is recommended to ask a professional to install it.

    When installing the air conditioning drain pipe, it is necessary to pay attention to the location of the drain pipe, the length of the bright dust, the slope and the fixing method, etc., to ensure that the water can be discharged smoothly and avoid water leakage and other problems.

    In general, the drain pipe should be located underneath the indoor air conditioner so that the moisture can be discharged. Ask the installer to secure the drain to the wall or floor with clips or other fixtures to prevent it from shaking or moving. In addition, the slope of the drain pipe should be 1 50, that is, the height difference per meter length should be 2 cm.

Related questions
7 answers2024-06-28

Cut off the power supply, unplug the power supply, and turn off the air conditioner. How to clean the filter of Haier vertical air conditioner and remove the front panel of the air conditioner. Unscrew the screws with a screwdriver to remove the front panel of the air conditioner. >>>More

11 answers2024-06-28

Adjust the proper temperature to save power. The higher the temperature in the summer, the cooler the temperature in the winter. >>>More

9 answers2024-06-28

1. Check whether the air conditioner is running normally before cleaning, and then turn off the missing power supply. 2. Liquidate the floating dust of the air conditioner profile and establish a signage at the same time. 3. Remove the shell and panel of the air conditioner according to the manual, and take out the filter. >>>More

10 answers2024-06-28

The main factors that drain quickly or slowly in an air conditioner are: >>>More

14 answers2024-06-28

First, the water pipe in the machine is damaged. Second, the installation of the indoor unit is unqualified, and the pipe outlet is too high.