1. The three-dimensional parking lot site should be flat, solid and non-skid, and should meet the drainage requirements and meet the requirements of urban traffic, fire prevention and environmental protection. Underground car parking garages should avoid areas where the groundwater level is too high or the geological structure is particularly complex and undesirable geological areas, and avoid the main pipes and lines of underground public facilities.
Second, the design of the parking lot shall be submitted to the city and county urban planning management department for review, and shall be agreed by the city and county public security traffic management department. After the completion of the parking lot, it must be reviewed and accepted by the city and county urban planning management department and the public security traffic management department before it is allowed to use.
Third, due to special circumstances can not be in accordance with the requirements of the "rules" to build a parking lot, approved by the city, the county public security traffic management bureau department and the planning and management department, can appropriately reduce the area of the parking lot, but should not exceed the requirements of 70%. At the same time, the parking lot construction difference fee must be paid to the people of the city and county or their authorized agencies according to the area of the parking lot that is less built. The difference fee shall be handed over to the municipal and county finances for the construction of public parking facilities and shall not be diverted for other purposes.
The standard of the difference fee shall be prescribed by the municipal and county planning and management departments, public security management departments, and price management departments.
Fourth, without the approval of the relevant departments or not in accordance with the plan approved by the first department for the construction of parking lots; or change the nature of the use of the parking lot without approval, or arbitrarily occupy, lease, or stop using the parking lot, are illegal acts, and the urban planning administrative department in conjunction with the public security traffic management department shall order correction and restoration within a time limit; If it is not corrected or restored within the time limit, a fine of 30,000 5,000 yuan per parking space shall be imposed, and a fine of less than 500 yuan shall be imposed on the person in charge of the unit or the person directly responsible, and an application shall be made to the people's court for compulsory restoration.
5. If it is necessary to temporarily suspend or partially suspend service due to maintenance and other reasons, it shall be reported to the city and county public security traffic management department in advance. Due to special circumstances, the parking lot must be changed to other purposes, subject to the consent of the city, county planning and management departments and public security traffic management departments, reported to the city, county people or their authorized agencies for approval, and correspondingly build another parking lot. The area of the additional parking lot shall not be less than the area of the original parking lot, and a reasonable service radius shall be maintained.
-
Personally, I think there are 3 most important points to consider when designing: 1Access car speed 2Risk of failure 3Whether it is easy to access the car.
-
Basement project: Ceiling clearance height of lifting and traversing equipment; Easy lifting:.
Outdoor equipment: The width of the passage must be greater than 5m after installing the equipment;
The height of the equipment should not block the lighting of residents;
The possibility of passing the roadside installation plan and construction, etc.
Others should also be considered: ground size, fire safety, weight of the mechanical loading vehicle and the bearing range of the floor (ground), the number of households, the number of planned parking spaces, Party A's requirements for parking spaces, the placement of the reserve power supply, and so on. )
In fact, the Miura garage has done a better job in terms of equipment installation capacity, maintenance, and quality of electrical components!!
Hope it helps.
-
Two-storey lifting simple three-dimensional parking space, generally 5 meters long, wide meters, high meters, load less than 2 tons (one floor). However, many medium and large SUVs are too large in size, so they cannot be parked in such parking spaces, so they need to be designed according to the largest size of the vehicle, and they need to increase the load capacity by at least 3 tons.
-
The height of the entrance and exit of mechanical parking equipment should generally not be less than 1800mm, the height of the passage of people inside the parking equipment should generally not be less than 1800mm, and the width of the channel should be increased by more than 500mm on the basis of the width of the vehicle suitable for parking.
Mechanical parking equipment has two layers, three layers, four layers, five layers, generally not more than five layers, but also more than seven layers, some have also done 18 layers, but relative to the low layer of lifting speed to ensure that customer use requirements.
-
If you choose a two-storey lifting and traversing class, the clear height of the basement must reach meters, and if there are ventilation and fire hoses, the clear height may be changed. Type D car 5000 * 1850 * 1500 T type 5300 * 1900 * 1550 K type car 5000 * 1850 * 2050, these three models are currently the most used.
The size of the garage is determined according to the model of the vehicle parked, that is, the needs of customers, the size of different types of parking equipment is also different, and the specific size should be determined according to customer requirements and on-site conditions.
-
What is a three-dimensional garage? Let's take a look
A three-storey garage is a mechanical or mechanical equipment system used to access or store the largest number of vehicles. It is also an effective tool for professional parking lot management companies to increase parking lot capacity, increase revenue, and increase parking fee income. The first three-storey garage was built in 1918 as a parking garage for a hotel (i.e., HotellaSalle) at 215 West Washington Avenue in Chicago, Illinois, USA, which was demolished in 2005, but a 49-story apartment building was later built on the site.
Garage Advantages:Compared with the underground garage, the three-dimensional garage can more effectively ensure the safety of people and vehicles, people in the garage or the car is not allowed to park in the position, the entire equipment controlled by the electronic control will no longer run.
Principle of three-dimensional garage:
The working principle of the three-dimensional garage: a plurality of carriers like hanging baskets are arranged in the vertical plane, the vehicle is accessed and parked in the mode of circular movement, when the carrier of the required parking vehicle is moved to the garage entrance and exit in a clockwise or counterclockwise direction, the driver enters the garage and the car is deposited or taken out to complete the access process.
-
The design of the three-dimensional garage should be designed according to the physical situation of the site, and in the design, the specific size of the electrical, the specific size of the site, civil engineering, fire protection, and the owner's requirements are very related. Miura Garage is one of the largest three-dimensional garage manufacturing enterprises in South China, and there are many relatively large cases in Guangdong, Hunan, Guangxi and other places.
-
There are standards in this industry, as early as 98 this standard has been introduced, and now many garage design requirements and construction requirements are based on this standard, there are a lot of them, for example, if there are only two exits in the basement, then the number of parking spaces must be less than 500 spaces. It is recommended that you go and look at the standards.
-
The three-dimensional garage has a relationship with the site and the previous civil engineering, this should be negotiated with the garage manufacturer, garages such as Dayang, Brilliance and other good three-dimensional garages hope to help you...
-
The size of the car and the load capacity of the car
As well as the purchaser's requirements for the overall garage, and finally the basic dimensions of the garage location.
It is also necessary to refer to the drawings of the site to see if it is suitable for construction.
If it is an underground garage, the net height of the two floors requires meters, and the three-story is meters, etc.
Qingdao Jinhua Industrial Group, Xu Kai.
-
There is a Weifang Ocean in Shandong, which is more professional and good.
-
The whole garage is designed with a PLC to carry out unified management and monitoring of the garage, and the longitudinal and horizontal transmission device of the vehicle carrier is controlled by the PLC to complete the access operation of the vehicle. The transfer in and out of the vehicles in each parking space shall be dispatched by the PLC according to the current storage situation of the vehicles in each parking space in accordance with the corresponding dispatching strategy.
The automatic storage and driving control system of the three-dimensional garage includes two sets of weak current and strong current systems. The weak current system mainly includes the acquisition, alarm and control output of various signals. The PLC outputs the signal to the contactor coil to control the contactor on and off.
The strong current system includes the motor control line of the vehicle-containing plate, the forward and reverse contactor of the control motor, the salty taste in place and the upper and lower stroke limits of the vehicle-containing plate. The garage adopts a parking space retrieval device instead of manual positioning, and a lifting device is used to transport the car in place. The system is equipped with an emergency stop switch at the panel, and when a more accident occurs, press the emergency stop switch to cut off the power supply of all motors, so that the vehicle tray can not continue to run, so as to protect the safety of personnel and equipment.
The system output control signal includes the control motor running direction signal, the control motor running signal, the control electromagnet gain and loss signal, the control of the light alarm signal, and the control of the garage lighting signal.
The lifting and transverse three-dimensional garage is a typical interdisciplinary mechatronics product, integrating mechanical, electronic and information technology. Among them, the rational use and combination of electronic technology, information technology and sensing technology constitute the control system of the garage. The control system of the lifting and transverse three-dimensional garage is an important part of the whole garage system, and it is also the core of the garage system.
The actuator is the "limbs", the framework is the "body", and the control system is the "brain". It directs every operation of the garage and monitors the status of the entire system.
Weifang Dayang is not bad, our community is.
-
What do you want to do? Do you want to design a three-dimensional garage or a structure?
-
There are a lot of requirements, depending on how you look at it, such as mechanical is important, electrical is also very important.
-
1. The three-dimensional garage is a mechanical or mechanical equipment system used to access and store vehicles in the largest quantities.
2. The three-dimensional garage is mainly made of steel structure or reinforced concrete materials.
3, the three-dimensional garage can be more effective than the underground garage to ensure the safety of people and vehicles, people in the garage or the car is not allowed to park in the position, the whole equipment controlled by the electronic control will not run. It should be said that the mechanical garage can be managed to achieve a thorough separation of people and vehicles. The use of mechanical storage in the underground garage also eliminates the need for heating and ventilation.
4. In the "Special Equipment Catalog" promulgated by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, the three-dimensional garage is divided into nine categories, specifically: lifting and transverse movement, simple lifting, vertical circulation, horizontal circulation, multi-layer circulation, plane movement, roadway stacking, vertical lifting and special lifts for automobiles.
-
The three-dimensional garage is to ask for parking spaces for space, which is generally a steel structure.
-
The three-dimensional garage is rising with the increasing number of urban vehicles and less and less available land, mainly to the development of space. It is mainly a steel structure frame, which has a variety of forms, and is mainly used in China at present.
-
Generally, it is a steel structure, and the parking space is extracted by mechanical or hydraulic transmission. Weifang Ocean is good, our community uses the ocean.
-
The three-dimensional garage is mainly made of steel structure or reinforced concrete materials. The three-dimensional garage can be made into a multi-storey one, which is higher than the land utilization rate of the general ordinary garage. The car is transported to the ground floor through mechanical transmission, for example, a 7 8m place can only support 3 cars for ordinary parking, and if it is done for block parking, it can currently park 50 cars.
It can greatly save land resources.
-
It consists of a mechanical part and an electrical part.
The mechanical three-dimensional garage is a mechanical equipment system used to access and store vehicles, and it is a great tool to solve the problem of urban parking. If divided according to the standard of "JB T8713", the three-dimensional garage can be divided into the following 9 categories: >>>More
Architecture or product design?
Baylor University Application Requirements: (1) Bachelor's degree applicants must have graduated from high school with a TOEFL score of 540 on the paper-based test and 207 on the computer-based test. GPA requires B-. >>>More
Hello, what are the VAT application requirements in France? >>>More
If it's a girlfriend, the appearance of the conversation, that's it. >>>More