Generator instruction manual, how to use the generator

Updated on science 2024-03-02
9 answers
  1. Anonymous users2024-02-06

    Provide specific models, I will help you find.

  2. Anonymous users2024-02-05

    Generator operation process:

    1. Preparation: disconnect the high-voltage switch in the distribution room and close the isolation switch to the power generation position.

    1. Merge the isolation switch of the generator room to the power generation position.

    2. Check the cooling water, lubricating oil, and fuel storage of the generator, and replenish it in time if it is found to be insufficient.

    3. Check whether the connecting parts, fasteners and manipulating parts are loose, falling off and stuck. Whether the connection of each wire is firm, correct and in good contact.

    4. Open the control cabinet under the generator operation screen, close the switch switch, and wait for the display screen to be powered. Press the page up and down button to view the relevant operation records of the generator, find abnormal conditions, deal with them immediately, and prepare for power generation.

    Second, start running:

    1. Press the start button to start the generator, and at the same time, pay attention to whether there is mechanical noise, abnormal vibration, etc.

    2. During operation, the operator closely monitors the voltage, frequency, current, power factor, oil temperature, oil pressure, water temperature, charging current, speed and other instrument indications and changes of the generator set through the instrument. When the specified value is exceeded, it should be checked and taken in time to resume operation only after returning to normal.

    3. The emergency stop button on the control screen panel is only used in case of emergency, and the generator will stop immediately after pressing the button, and at the same time send out an audible and visual alarm.

    4. After the generator is running normally, close the main switch (low-pressure air switch) of the generator set, and the generator will supply power to the electrical load.

  3. Anonymous users2024-02-04

    The generator is generally an alternator, which is used on alternating current equipment, and can be used by connecting a voltage regulator, and if it is a direct current equipment, a rectifier is also needed for rectification.

  4. Anonymous users2024-02-03

    1. Generator start-up operation process:

    1.Check that the generator output switch is in the open position.

    2.Check that the amount of diesel fuel in the tank should be sufficient.

    3.Check that the battery cable is firmly connected and the cable is not damaged.

    4.Check that the coolant in the cooling system should be sufficient.

    5.Check that the exhaust pipe is clear and free of obstructions.

    6.Check that the cooling fan is in a clear position and free of obstructions.

    7.Check that the lubricating oil level is in a good position.

    8.Check that there is no air inside the suction pipe.

    9.Switch the generator-controlled DC power switch to the ON position.

    10.Toggle the generator control switch to the "ii on" position.

    11.Check that the controller self-test is normal and there is no abnormal alarm signal.

    12.Check that there are no people parked at the engine exhaust port.

    13.Press the manual key and the manual mode light will be on.

    14.Press the power button, the diesel engine starts, the generator enters the starting procedure, and the power generation indicator is red at the same time.

    15.Check the relevant data on the LCD screen and display the message "Unit is operating normally".

    2. Generator shutdown operation process:

    1.Check that the generator output switch is in the open position.

    2.Press the Stop reset button.

    3.Wait for the engine to stop after a delay.

    4.Toggle the generator control switch to the "i off" position.

    5.Check the controller LCD screen for 10 seconds and turn it off. Switch the generator-controlled DC power switch to the off position.

    Note: When it is found that the generator set is running abnormally or the controller is alarmed, and the generator set has not stopped running, you can immediately press the "emergency stop" button to force the power supply of the controller to stop the operation of the engine, and the button can be rotated to reset it after troubleshooting. If weather permits, open all doors to ensure good ventilation during operation.

  5. Anonymous users2024-02-02

    1. Tip 1: Learn from technicians with an open mind.

    When consumers buy a portable chain generator, the technician will give you a detailed explanation and demonstration of the correct method of generator operation and maintenance, then you have to listen to it. Although generators are purchased with instructions, the technician's words and deeds are sure to be faster and more effective than if you were to study the instructions on your own.

    2. Tip 2: Give the generator a "comfortable" environment.

    Generators should not be used in a humid environment, nor should they be placed indoors, because poor indoor ventilation can easily cause carbon monoxide poisoning. In addition, generators must be separated from flammable and explosive materials by more than 1 meter when in use.

    3. Tip 3: The generator must be isolated from the public power grid when it is used.

    Before connecting the generator to the power grid at home, be sure to close the main power gate and disconnect it from the public grid. If it is not disconnected, the generator will be reversed to the public grid, and two accidents can occur, one is that the generator burns under a huge load (think about how big the load of the public grid should be), and more dangerously, it can cause a fatal risk of electrocution to the power personnel who are maintaining the public grid. Second, once the public power grid suddenly comes in, the strong current will immediately burn the generator, and even cause a disaster, threatening the life safety of consumers.

    4. Tip 4: Let the generator run healthily and don't overload it for a long time.

    A generator with a rated power of 2 kilowatts can withstand the electricity load of kilowatts in a short time, but consumers must not do this kind of "killing chickens and eggs". Overload operation will shorten the service life of the generator, increase noise and exhaust pollution, and more seriously, the output voltage cannot reach the rated value, which is easy to cause damage to electrical appliances.

    5. Tip 5: Always check whether the oil of the generator is enough.

    Most generators are equipped with protective devices that cannot be started when there is not enough oil. In addition, when refueling the generator, be sure to stop it first and then refuel; Do not smoke while refueling, do not spill fuel, and if fuel spills, wipe it off immediately with a rag.

  6. Anonymous users2024-02-01

    First take the battery and let Lu go to Weixiang to charge, the principle of electric start is to use the existing electric energy to drive a Tanshan with a starting motor, so that the machine starts! It's the same as hand-cranking, but it's just using the force of a motor instead of manpower!

  7. Anonymous users2024-01-31

    It mainly depends on what kind of generator you are, and you generally use other energy sources, such as firewood and oil.

    The electric start you mentioned is used in large power stations, and the power supply of Litong Shen Magnet is started.

  8. Anonymous users2024-01-30

    Hello, preparation before the start of the generator set:1Check the oil level, coolant level, and fuel volume of the lubricating oil; 2.

    Check whether there is oil leakage and water leakage in each pipeline and joint of the diesel engine oil supply, lubrication, cooling and other systems; 3.Check whether the electrical circuit has hidden dangers such as broken skin, whether the electrical circuit of the grounding wire is loose, and whether the connection between the unit and the foundation is firm; 4.If the ambient temperature is below zero, a certain proportion of antifreeze must be added to the radiator; 5.

    When the diesel generator set starts once or starts again after stopping for a long time, the air in the fuel system should be exhausted with a hand pressure pump. Startup:1

    After closing the safety in the control box, press the start button, press the button for 3 5s, if the start is not successful, you should wait for about 20s to start again. If the start is unsuccessful for many times, you should stop the start operation, eliminate the fault factors such as battery voltage or oil circuit, and start again; 2.When starting, the oil pressure should be observed, if the oil pressure is not displayed or the hail type is very low, it should be stopped immediately for inspection.

  9. Anonymous users2024-01-29

    Yingtai Power Diesel Generator is a professional manufacturer.

Related questions
12 answers2024-03-02

Generators are also known as synchronous generators, and the power systems of China and a bunch of countries led by the former Soviet Union are all 50Hz frequency, and 60Hz in Western countries. When you say 1500 rpm, you mean a generator with 2 pairs of poles. The 1500 rpm motor you are talking about is also a synchronous motor, if it is an asynchronous motor, the speed should be about 1480, there is a slip rate, and the asynchronous motor is divided into squirrel cage type (such as Y series) and winding type (such as ZR series). >>>More

14 answers2024-03-02

The new machine changes the oil once every 8-10 hours. After 150-200 hours, replace the oil, filter element, filter screen, and spark plug.

5 answers2024-03-02

Flexible packaging. At present, the most popular packaging in the market is the simple flexible packaging of the stretch film for diesel generators. The packaging cost is cheap, the packaging is simple, mainly used for short-distance transportation, the current diesel generator is low, the profit is low, and the generator manufacturers are the same as the use of the most cheap packaging. >>>More

6 answers2024-03-02

1. Remove the dust cover first;

2. Dismantle three more heart-piercing wires; >>>More

6 answers2024-03-02

What are the things to pay attention to when buying a diesel generator? >>>More