What is Hot Water Gas Boiler Fault 009?

Updated on home 2024-04-21
13 answers
  1. Anonymous users2024-02-08

    Many people have encountered the problem that there is no spark in the gas stove, and when encountering such a problem, first of all, we have to check the battery to see if the battery is still charged? If there is no electricity, you need to change the battery. Next, we press the knob to see if there is a spark, if there is no spark, it is a problem with the ignition needle, just change the ignition needle.

    If the ignition needle is replaced, it is that the pulser does not work, see if the connection between the pulse and the battery box is intact, if it is intact, then it has to be replaced with a new pulser.

    Another problem we often encounter is that the gas stove has a spark, but it does not ignite. We first have to check if there is gas coming out, and we can use a lighter to light it and try it. If the ignition does not ignite, we turn the ignition needle so that the spark hits the edge of the nearest small hole, and adjust the damper, because the damper is too large, the mixing ratio of gas and air is too small, and it is not easy to ignite.

    Adjust down first to make the gas concentration high; After ignition, adjust the damper to the blue flame, but the bottom of the flame does not leave the blowhole.

    Another common problem we encounter is that the gas stove can be lit on fire, but as soon as the hand is released, the fire is extinguished. We can overhaul from the following aspects, after ignition, after ignition, whether the fire has burned the thermocouple, if not, it is possible that the fire cover is not placed, it is possible that the small hole of the thermocouple is blocked by debris or water so that the fire can not come out, it is possible that the thermocouple is displaced or sinking, and it can be eliminated; After ignition, the fire burns to the thermocouple. It is possible that the thermocouple itself is damaged, and it can be replaced; It is possible that the interface between the thermocouple and the valve body is not in good contact.

    In addition to the above problems, we will also encounter the situation that the knob of the gas stove cannot be pressed. The solution to this problem is relatively simple, generally because the knob rod of the valve body assembly is not installed in the center of the panel hole, and the bottom of the knob is stuck, and the panel can be adjusted.

  2. Anonymous users2024-02-07

    Cause of failure: unstable air pressure, or a problem with the wind direction. Fault Symptom:

    Prompt 03 is faulty, it does not work, and the fiber does not start. Solution: 1. Remove the heat shield outside the combustion chamber.

    Press the black button in the middle of the two red lines on the top side, and turn on the switch after re-energizing; 2. There is no word in the gas meter (there is no imitation gas in spring); 3. The battery of the gas meter is low; 4. The gas valve is not opened; 5. Contact the after-sales personnel to touch the door on the forest for detection.

  3. Anonymous users2024-02-06

    Gas water heaters.

    Show what fault 03 is.

    Hello dear, the cause of the failure: wind and pressure failure.

    Fault phenomenon: prompt E03 fault**, Tanjia fan fault display (E3)1, AC fan terminal.

    Loose, the fan does not rotate.

    2. The starting capacitor of the fan is damaged.

    3. The computer board is damaged. Let the Dan wall-hung boiler.

    There is an abnormality, or it does not ignite.

    Workaround:1It may be that the ventilation pipe is blocked, try to unclog it.

    2.Reset, restart the wall-hung boiler after the power is off.

  4. Anonymous users2024-02-05

    Explanation of the cause of the failure:

    1.If the smoke pipe is blocked, it can be recovered by cleaning up the blockage and removing the dirt attached to the inner wall of the smoke pipe.

    2.If the wind pressure switch fails, if it fails and stops working regardless of whether it is unblocked, there will be a smoke exhaust error, and the wind pressure switch needs to be replaced.

    3.Fan failure, the fan is responsible for the wall-hung boiler to transport the burning oxygen and discharge the generated wide mountain exhaust gas, if it fails, there will be an error, replace the fan.

    4.The connection of the fan or switch falls off, and the connection of the fan or the air pressure switch will fall off the smoke pipe failure, as long as the line of the fan or the wind pressure switch falls off, as long as the line that falls off is welded in the sail.

    5.If the circuit board is faulty, if there is a problem with the circuit board of the wall-hung boiler, many functions will have problems, and it is recommended not to replace it yourself when it is found that the circuit board is faulty.

  5. Anonymous users2024-02-04

    This fault is a failure of the high-voltage switch due to excessive pressure or damage to the high-voltage switch. It is recommended to check whether the refrigerant system 1 is clogged, check whether the water heater is dry, and check whether the magnet can be reset; Check whether the thermal protection is faulty, and reset it; Check whether the fuse is burned out, and it is best to replace the fuse; Check whether the Hall sensor is stuck*, and clean up the debris; Check whether there is any stolen goods in the temperature measuring head, clean the temperature measurement and deity the stolen goods; Check if the water pressure is normal, and if the water pressure is too low, find the property to increase the water pressure.

  6. Anonymous users2024-02-03

    The display of alphanumeric numbers on the screen is a glitch that reminds you of the problem**. As for the specific question, because each brand has differences, you can look at the product manual that came with the brand when you bought it at that time to understand what the problem is. Or call the after-sales service of this brand directly, say the specific problem, and let them arrange someone to repair it in time.

  7. Anonymous users2024-02-02

    The display of alphanumeric numbers on the screen is a glitch in the Lackena Awakening Problem**. As for the specific question, because each brand is different, you can read the product manual that came with the purchase of this brand at that time.

  8. Anonymous users2024-02-01

    Summary. 1. The 09 displayed by the natural gas wall-hung boiler is its fault**, which is expressed as: ignition fault, that is, ignition is not ignited.

    2. Solution: You can restart the wall-hung boiler and try again, if it still can't burn normally, it is recommended to go directly to the after-sales maintenance office or customer service to ask technicians to come for maintenance.

    3. When the wall-hung boiler is working, the temperature of the heating, hot water outlet pipe and smoke pipe at the bottom is high, and it is strictly forbidden to touch it to avoid scalding.

    What is the natural gas boiler burner fault**009.

    1. The 09 displayed by the natural gas wall-hung boiler is its fault**, which is expressed as: ignition failure, that is, the big point does not catch fire. 2. Solution:

    You can restart the wall-hung boiler and try again, if it still can't burn normally, it is recommended to go directly to the after-sales maintenance office or customer service to ask the technician to come for maintenance. 3. When the wall-hung boiler is working, the temperature of the heating, hot water outlet pipe and smoke pipe at the bottom is high.

    If my answer is helpful to you, please also give a thumbs up (comment in the lower left corner), look forward to your like, your efforts are very important to me, and your support is also the driving force for my progress. If you feel that my answer is still satisfactory, you can click on my avatar for one-on-one consultation. Finally, I wish you good health and a happy mood.

    The boiler is a special equipment, which belongs to the pressure vessel and is also an energy conversion equipment. Boilers can be divided into different categories according to different categories: according to the type of fuel, it can be divided into gas boilers, oil-fired boilers, biomass boilers, electric boilers, coal-fired boilers, etc., while natural gas boilers are a type of gas boilers, which is a boiler product that burns natural gas as fuel.

    Natural gas boilers can be divided into horizontal natural gas boilers and vertical natural gas boilers according to the product type; According to the pressure, it can be divided into pressure natural gas boiler and atmospheric natural gas boiler; According to the use of Xianyuanzhao products, it can be divided into natural gas steam boilers, natural gas hot water boilers, and natural gas boiling water boilers; According to the rated evaporation capacity (rated thermal power), it can be divided into small natural gas boilers, medium-sized natural gas boilers and large natural gas Xiaopai blind boilers.

  9. Anonymous users2024-01-31

    Summary. Dear Hello: The gas water heater shows that 03 is a wind pressure fault.

    Fault phenomenon: prompt 03 fault**, fan fault display 03. 1. The terminal of the AC fan is loose, and the fan does not rotate.

    2. The starting capacitor of the fan is damaged. 3. The computer board is damaged. The wall-hung boiler is abnormal, or it does not catch fire.

    Workaround:1It may be that the ventilation pipe is blocked, unclog it.

    2.Reset, restart the water heater after the power is off.

    Hello: The gas water heater shows that 03 is a wind pressure fault collapse. Fault Huai pants phenomenon:

    Prompt 03 fault**, fan fault display 03. 1. The terminal of the AC fan is loose, and the fan does not rotate. 2. The starting capacitor of the fan is damaged.

    3. The computer board is damaged. The wall-hung boiler is abnormal, or it does not catch fire. Workaround:

    1.It may be that the ventilation pipe is blocked, unclog it. 2.

    Reset, restart the water heater after powering off.

    Pro: There is another reason 03 is that the high-pressure switch of the water heater is faulty and the problem is flushed. It is also a kind of protection function when the switch is disconnected, and it may also be caused by a variety of other reasons.

    On the one hand, the high-voltage switch is broken, on the other hand, it may be that the system is blocked, the water temperature is too high due to the temperature sensor of the water tank falling off, or there is non-condensable gas in the refrigerant system, etc., which leads to the failure of 03** now. There is no way to repair the flushing, so you can only contact after-sales professionals to check and deal with it.

  10. Anonymous users2024-01-30

    The gas water heater shows 03 what is the fault Hello dear, the cause of the failure: wind pressure failure. Fault Symptom:

    Prompt E03 fault**, fan fault display (E3)1, AC fan terminal loose, fan does not rotate. 2. The starting capacitor of the fan is damaged. 3. The computer board is damaged.

    The wall-hung furnace is out of the bird and knows that the key is not a coincidence, or it can't catch fire. Workaround:1

    It may be that the ventilation pipe is blocked, try to unclog it. 2.Reset, restart the wall-hung boiler after the power is off, and try Mengtong.

  11. Anonymous users2024-01-29

    Midea gas water heater, showing the fault **E5, indicating that it is a wind pressure fault, you can take a look at the manual, there is a simple description of ** on it.

    1. First of all, see if the wind blows outside, if the outdoor wind is too strong, the wind pressure switch can not be turned on, the water heater can not work, and it can work normally after the wind stops. This is also a common sense for the use of gas water heaters.

    2. Carbon deposition in the heat exchanger. If the water heater has been used for more than a year and has never been maintained or repaired, carbon deposits will also make the water heater work abnormally, please ask the after-sales personnel to clean it, and the fault will generally be eliminated.

    3. If there is no wind outdoors and carbon deposition factors are excluded, the fault of the wind pressure switch itself is considered. It may be that the air pressure detection port is blocked, the silicone tube falls off, or the wind pressure switch connection line falls off.

    It is recommended to unplug the air pressure switch and restart the machine, and then short the air pressure switch after the fan rotates, if the ignition is normal, it can be judged as the wind pressure switch problem, and the wind pressure switch needs to be replaced.

  12. Anonymous users2024-01-28

    Gas water heater malfunction**90! It's as simple as that, and so can you!

  13. Anonymous users2024-01-27

    Ignition failed. Solution: It is necessary to manually reset, and then check the gas switch to ensure that the gas supply of the water heater is normal.

    Faulty heating temperature sensor, sensor overheating. Solution: It is necessary to reset the operation, or to restart after power-off, if both methods do not work, it needs to be repaired.

    Faulty shower temperature sensor, sensor overheating. Solution: It is necessary to reset the operation, or to restart after power-off, if both methods do not work, it needs to be repaired.

    EEROM, chip failure. Solution: At this time, the necessary manual reset is carried out, and then there is no effect to be repaired.

    Water heater system is short of water. Solution: Reset operation or power off and restart. Then check whether the pressure gauge water pressure is too low, and refill the water.

    False flame, no actual temperature rise. Solution: Reset or restart after power-off.

    External factors turn off and the water heater is not working properly. Solution: Check whether the gas is stopped at home, and then check whether the flue is in a windward state, if not, it needs to be repaired.

    Mechanical temperature control overheat protection of water heater. Solution: Ask the user if the heating pipe is closed, if everything is normal, it needs to be repaired.

    Reason 2: The heating tube takes too long and needs to be replaced.

Related questions
16 answers2024-04-21

In addition to the inherent risks of the boiler such as overpressure and safety appendage failure, there are also gas safety risks such as gas leakage and furnace deflagration. The cost of natural gas heating is several times that of coal-fired heating, which is relatively high, while the inverter intelligent control core used in the electromagnetic boiler has high energy saving, and the heating cost is not much more expensive than coal-fired heating. >>>More

13 answers2024-04-21

Be. 1. What is open flame equipment?

Open flame equipment refers to the heating equipment and exhaust gas incineration equipment where the combustion chamber is connected with the atmosphere and there is an exposed flame under abnormal conditions. The fire distance between "open flame equipment" and other equipment and buildings. >>>More

16 answers2024-04-21

Households that use gas are still less economical than fuel, and they are environmentally friendly, and those with a large number of homes can also support it. Now Europe is also pushing for oil-gas dual fuel. >>>More

22 answers2024-04-21

The temperature of the air outlet of the domestic floor heating gas boiler depends on the type of boiler used: >>>More

7 answers2024-04-21

E2 is an error that indicates a malfunctioning water heater**. >>>More