The encoded smoke detector is a smoke detector that can write the address code, which can be used directly with the host, and the non-coding means that the smoke detector address code cannot be written, and the module that can write the address code can be used with the host.
-
The battery and the coded one on the non-coded smoke detector should be able to be used in the same way, and this should be because they are the same thing, so this should be a set, so it should be able to be used when the blood is in progress.
-
Hello, friends non-coding smoke detector installation battery and coding is not suitable. It's the same, but the effect should be about the same, I hope it can help you.
-
The battery on the non-coded smoke detector is not necessarily the same as that coded, because it is not possible to use it if there is no coding function as a whole.
-
But you have no problem using it, because we know it's all possible.
-
Probably, the battery code is different sizes, and it really doesn't bother with me.
-
Personally, I guess that's the case, but I'm not sure because I'm not a major in this area, so I don't know.
-
Does the battery installed on the non-coded smoke detector be the same as that of Tianma? It should be the same.
-
Should the non-coding be equipped with a battery and use it just like the coding? No.
-
The basic working principle is the same, except that the coding detector has more coding circuits, which can be connected to the host of the same manufacturer of the detector to complete the communication.
Non-coded smoke detectors are generally only for domestic use, and they can work with a battery installed.
There is also a kind of non-coded smoke detector is intrinsically safe or anti-riot type, installed in anti-riot places, this kind of detector generally has a module or host to receive signals in the general safety area.
-
The function is the same, the difference is one with an address and one without an address!
-
Coded, the host can detect it, and when it has a problem, the host can see it above! It's not coded, it's bad, and I don't know! There is no coding convenience! If there is a problem, it will come out!
-
The non-coded ones can be connected to modules, and the modules share a set of detection lines with the coding equipment.
I've tried to explain it in the words you mentioned above.
Non-coded detectors cannot be wired directly to the coded device.
-
Non-coded equipment should use modules to input or output signals, and modules and devices can share a set of detection lines at the same time.
-
The encoded ones include intelligent smoke detectors, temperature sensors, manual alarm buttons, interface modules, control modules, etc., which can be coded with addresses and automatically identified by the host when communicating with the host.
Non-coded smoke sensors, temperature sensors, manual alarm buttons, fire hydrant buttons, etc., if connected to the intelligent host, should be connected and converted through the interface module. The interface module is coded by the intelligent host that can be identified, and the general interface module can be connected to about ten non-coded detection components, and the load capacity of the interface module of different manufacturers will be different. The isolation module is not addressed, and automatically shields part of the short circuit when the bus is shorted.
-
The building you mentioned is a first-class system protection object and requires the installation of fire detectors.
Generally speaking, point smoke detectors will do.
For the specific setting method, please refer to the Code for Fire Protection Design of Buildings GB50016-2006, GBT50116-1998 Code for the Design of Automatic Fire Alarm System and GB50166-2007 Code for Construction and Acceptance of Automatic Fire Alarm System.
-
According to the requirements of the national standard, it is not possible to use it now, that is, if the drawings reviewed before May 2015 are designed to be used, they are not allowed to be used after May.
-
Some places can still be installed, and they are used less
-
1. All the codes are commonly known as with addresses, that is, the alarm can display a number on the host. Non-ordinary, that is, the switching quantity.
There are operones on the non-coding region, such as promoters and terminators, which are the recognition and binding sites of RNA polymerase, without which RNA polymerase cannot bind to genes and cannot be transcribed. >>>More
All on the DNA sequence, different segments.
Small intranuclear RNA: located in the nucleus.
There are 5 kinds of SNRNA, called U1, U2, U4, U5, and U6, which form complexes with a variety of proteins and participate in the intron processing and splicing of HNRNA in eukaryotic cells. >>>More
Installation method This kind of you should find an installation master Each one has a manual.
The BenQ 5000e scanner is an antique, and the era when this scanner was produced was around the early 2000s, which was the era of Windows 98 Windows XP. I have a scanner of this model. The driver can be successfully installed in XP or Win98. >>>More