Should the fire pipe enter the civil air defense with an explosion proof valve?

Updated on society 2024-06-22
11 answers
  1. Anonymous users2024-02-12

    The code requires that the water supply pipeline must be installed on both sides when crossing the civil air defense zone.

  2. Anonymous users2024-02-11

    Here are some of the well-known brands recognized in the valve industry, which are widely recognized and have a high reputation. While rankings may vary depending on time and market conditions, the following brands are generally considered to be among the top brands in the valve industry:

    The following influential first-line brands of water system valves and industrial valves can be used as a reference, but for reference only: Suzhou Neway Valve, Shanghai Guanlong Valve, Shanghai Qizhong Valve, Sanhua, Su Yan, Shentong, Su Valve, Nanfang, Jiang.

    First, the word Yao. The above manufacturers are only estimates and references, and the specific situation may vary or fluctuate at any time due to changes in a series of factors such as changes in the market, the size of the competition pattern, and the stability of product quality. As an indispensable key device in industrial production and civil facilities, the quality and reputation of the valve brand directly affect the satisfaction and trust of users.

    These brands are known in the valve industry for their innovative technology, high-quality products and reliability. It is important to note that the market and industry are evolving rapidly, and different rankings may vary depending on time and region. For the most up-to-date ranking information, it is recommended to refer to industry reports, professional organizations or market research data for more detailed and accurate information.

  3. Anonymous users2024-02-10

    As follows:

    1. When the water supply pipeline is introduced from the entrance, it should be set on the inside of the protective airtight door; When introduced from the civil air defense enclosure structure, it should be set on the inner side of the civil air defense enclosure structure; When passing through the protective airtight partition wall between the protective units, it should be set on the pipes on both sides of the protective airtight partition wall.

    2. The nominal pressure of the protective valve should not be less than.

    3. The protective valve should be a gate valve or globe valve with a stainless steel or copper core.

    Valve is a mechanical device that controls the flow, direction, pressure, temperature, etc. of the flowing fluid medium, and the valve is the basic component of the pipeline system. Valve fittings are technically the same as pumps and are often discussed as a separate category. The valve can be operated manually or with a handwheel, handle or pedal, and can also be controlled to change the pressure, temperature and flow rate of the fluid medium.

    These changes can be operated continuously or repeatedly, such as safety valves installed in hot water systems or steam boilers. In more complex control systems, automatic control valves are used as needed to regulate the changing set points of flow through the pipes based on external inputs. The automatic control valve does not need to be operated manually, according to its input and settings, so that the valve can accurately control the requirements of the fluid medium.

    According to the material, the valve is also divided into cast iron valve, cast steel valve, stainless steel valve, chromium-molybdenum steel valve, chromium-molybdenum vanadium steel valve, duplex steel valve, plastic valve, non-standard customized and other valve materials.

  4. Anonymous users2024-02-09

    Code for the Design of Civil Air Defense Basements

    6 2 13 The setting and installation of protective valves on the water supply pipeline of the air defense basement shall meet the following requirements:

    1. When the water supply pipeline is introduced from the entrance, it should be set on the inside of the protective airtight door; When introduced from the civil air defense enclosure structure, it should be set on the inner side of the civil air defense enclosure structure; When passing through the protective airtight partition wall between the protective units, it should be set on the pipes on both sides of the protective airtight partition wall.

    2. The nominal pressure of the protective valve should not be less than.

    3. The protective valve should be a gate valve or globe valve with a stainless steel or copper core.

  5. Anonymous users2024-02-08

    Hello, dear, the requirements of the civil air defense explosion-proof valve are as follows: according to the "GB50038 Civil Air Defense Basement Design Code" 1 When the water pipeline of the civil air defense anti-explosion door is led from the entrance and exit, it should be set on the inside of the protective airtight door; When introduced from the civil air defense enclosure structure, it should be set on the inner side of the civil air defense enclosure structure; When passing through the protective airtight partition wall between the protective units, it should be set on the pipes on both sides of the protective airtight partition wall. 2. The nominal pressure of the explosion-proof door should not be less than; 3. The explosion-proof door should be a gate valve or globe valve with a stainless steel or copper spool; The inner side of the civil air defense enclosure structure of the 4-person explosion-proof door should not be greater than 200mm from the proximal end of the valve, and the valve should have obvious opening and closing signs.

  6. Anonymous users2024-02-07

    Summary. Kiss! Hello, happy to answer your <>

    Crossing the civil air defense wall, the fire pipeline should be equipped with explosion-proof valves as follows: for crossing the civil air defense wall, the fire pipeline should be equipped with explosion-proof valves, it is necessary to add, the specification requires that the water supply pipeline through the civil air defense area must be installed on both sides of the protective valve. Civil air defense engineering pre-embedding precautions first, all air defense embedded casing must be embedded in advance, rigorous late opening, second, fire pipe through the civil air defense wall to be 20 cm away from the wall to add a gate valve, if both sides of the wall are civil air defense area, then both sides of the wall should be added to the gate valve, if one side is a non-civil air defense area, then only in the civil air defense area to join, third, cable tray, ventilation duct can not pass through the civil air defense wartime blocking.

    Fourth, PVC pipelines shall not be used, galvanized steel pipes shall be used, and PVC junction boxes shall not be used, and the connecting wires shall be welded at the joints of galvanized steel pipes. Fifth, the roof hole can not be greater than 150mm, the top of the hole needs to add a 6mm thick resistance piece, tighten it with bolts, sixth, the explosion-proof floor drain can not be omitted, it must be embedded in advance, seventh, the explosion-proof wave exhaust valve and the overpressure exhaust valve need to be welded and installed in a finished product, and the eighth, the closed pressure measuring pipe needs to be plugged on both sides of the wire. Hope mine can help you <>

    Do you have any other questions?

    Through the civil air defense wall, the fire pipe should be equipped with an explosion-proof valve.

    Kiss! Hello, happy to answer your <>

    Pro-crossing the civil air defense wall, the fire pipeline to add an explosion-proof valve as follows: for crossing the civil air defense wall, the fire pipeline to add an explosion-proof valve, is to add, the specification requires that the water supply pipeline through the civil air defense area must be aware of the need to install protective valves on both sides. Civil air defense engineering pre-embedding precautions first, all air defense embedded casing must be embedded in advance, rigorous late opening, second, fire pipe through the civil air defense wall to be 20 cm away from the wall to add a gate valve, if both sides of the wall are civil air defense area, then both sides of the wall should be added to the gate valve, if one side is a non-civil air defense area, then only in the civil air defense area to join, third, cable tray, ventilation duct can not pass through the civil air defense wartime blocking.

    Fourth, PVC pipelines shall not be used, galvanized steel pipes shall be used, and PVC shall not be used in junction boxes, and galvanized steel pipes shall be welded to connect the tung burning wire. Fifth, the roof hole can not be greater than 150mm, the top of the hole needs to add a 6mm thick resistance piece, tighten it with bolts, sixth, the explosion-proof floor drain can not be omitted, it must be embedded in advance, seventh, the explosion-proof wave exhaust valve and the overpressure exhaust valve need to be welded and installed in a finished product, and the eighth, the closed pressure measuring pipe needs to be plugged on both sides of the wire. Hope mine can help you <>

    Do you have any other questions?

    Is it OK to use pressure gate valve for civil air defense in basement? Can I not use a waterfall gate valve?

    Kissing can be ha, not less than can.

  7. Anonymous users2024-02-06

    Explosion-proof valves are generally used in civil air defense projects, and the main purpose is to prevent external risk factors from invading the inside of the shelter or leaking out of the safety problems caused by the shelter. The following are the requirements for civil anti-explosion valves::

    2.Sealing performance requirements: The sealing performance of the explosion-proof valve should meet the relevant national standards to ensure that the air will not leak out in the shelter and can effectively prevent external harmful substances from entering the shelter.

    3.Anti-corrosion performance requirements: The material of the explosion-proof sock wide valve should have excellent corrosion resistance, because the refuge is used in a closed period of long branches, if the material is not corrosion-resistant, it will affect the service life of the explosion-proof valve.

    4.Emission performance requirements: The civil air defense explosion-proof valve should have the ability to evacuate pollutants in the shelter to ensure that the exhaust gas and harmful substances in the shelter can be discharged in time in the event of a dangerous accident to protect the life safety of personnel.

    5.Reliable performance requirements: The civil air defense explosion-proof valve should have stable and reliable performance in the usual use process, and will not lose its function due to problems such as material aging and parts damage.

    The above are some requirements for civil anti-explosion valves, and the specific requirements can be adjusted according to the actual situation.

  8. Anonymous users2024-02-05

    Summary. The installation of the explosion-proof valve is directional, and the positive direction of the shock wave is the direction of movement of the main valve plate towards the spring compression, that is, the direction of closing the valve. In the opposite direction, only a small amount of traffic can be passed.

    The explosion-proof wave valve is a special protective equipment for basement protection, and it is an important facility for shock wave protection, with voltage stabilization and dissipation. Under normal circumstances, the circumferential door is in the normally open state, and the system medium is normal and unimpeded, and when the impact crosses the valve, the main valve valve plate is quickly closed under the shock wave pressure, and the shock wave is blocked at the outer end; Part of the impact in the valve has been under the action of the wave elimination valve, the guide wave chamber, due to the diffusion action, the shock wave pressure is rapidly reduced, the damage of the shock wave is eliminated, and the protection and protection are played

    How to install explosion-proof valves in fire pipelines through anti-airtight passages.

    The installation of the explosion-proof wave valve is tropical, and the positive direction of the shock wave is the direction of the movement of the main valve plate towards the spring compression, that is, the direction of closing the valve. In the opposite direction, only a small amount of traffic can be passed. The explosion-proof wave valve is a special protective equipment for basement protection, and it is an important facility for shock wave protection, with voltage stabilization and dissipation.

    Under normal circumstances, the circumferential door is in the normally open state, the system medium is normal and unimpeded, when the impact crosses the valve, the main valve grinding valve plate is quickly closed under the shock wave pressure, and the shock wave is blocked at the outer end; Part of the impact crossing in the valve has been under the action of the wave absorbing valve, and the shock wave pressure in the conduction and suppression chamber, due to the diffusion, the shock wave pressure is rapidly reduced, and the shock wave is broken, and it plays a role in protection and protection

    Installation Requirements1The installation of the explosion-proof valve can be installed at any angle2The minimum installation position between the two explosion-proof valves is 200 mm

  9. Anonymous users2024-02-04

    Summary. 3.Anti-corrosion performance requirements: The material of the explosion-proof valve should have excellent corrosion resistance, because the refuge is used in a long-term seal, if the material is not corrosion-resistant, it will affect the service life of the explosion-proof valve.

    Explosion-proof valves can be installed upright no.

    Pro, the requirements for explosion-proof valves are:

    2.Sealing performance requirements: The sealing performance of the civil anti-explosion valve should meet the relevant national standards to ensure that the air in the shelter will not leak out, and can effectively prevent the outside world from entering the shelter.

    3.Anti-corrosion performance requirements: the material of the anti-explosion valve should be matched with excellent corrosion resistance, because the refuge is closed for a long time, if the material is not corrosion-resistant, it will affect the service life of the explosion-proof valve.

    Dear, the explosion-proof valve can be installed vertically.

    I just wanted to ask if the explosion-proof valve can be installed upright.

    Explosion-proof valves can be installed in a standing position.

  10. Anonymous users2024-02-03

    Hello, in the civil air defense system, if there is a need to isolate between the two water pipes or to control the water flow, you can consider installing valves on both sides. This makes it easy to control, regulate and maintain the water flow. The benefits of retrofitting valves include:

    1.Isolation function: The valve can isolate the water flow between the two water pipes, and when the water flow needs to be closed or cut off, it can be achieved by closing the valve.

    2.Flow control: Valves can be used to adjust the size of the water flow, increasing or decreasing the amount of water as needed.

    3.Repair and maintenance: If a water pipe on one side needs to be repaired or replaced, by closing the corresponding valve, the whole system can be avoided from stopping the water or affecting the normal operation of other parts.

    However, whether a valve needs to be installed in a specific situation is determined according to the actual needs and design requirements. Therefore, it is recommended to consult a professional engineer or relevant technician to evaluate and make decisions according to the specific situation. They will take into account the characteristics of the system, safety, ease of operation, and other factors to make the most appropriate decision.

  11. Anonymous users2024-02-02

    Summary. Hello, the fire water supply pipeline is a fire hydrant or sprinkler pipe in the fire pipeline, but the fire pipe also includes the fire drainage pipe.

    Hello, the fire water supply pipeline is a fire hydrant or sprinkler pipe in the fire pipeline, but the fire pipe also includes the fire drainage pipe.

    Literally, there is nothing to say, and the fire rental pipeline refers to the pipeline materials used for fire fighting, connecting fire fighting equipment and equipment, and transporting fire fighting water, gas or other media. Due to special needs, there are special requirements for the thickness and material of the fire pipe, and the red paint is sprayed to transport the fire water. Fire pipes are divided into ductile iron pipes, copper pipes, stainless steel pipes, alloy pipes, composite pipes, and plastic pipes.

Related questions
4 answers2024-06-22

The fire pipe installation specification includes seven major aspects, namely the scope of the specification, pre-construction preparation, operation technology, quality standards, finished product protection, quality problems that should be paid attention to, quality records, etc. These aspects involve all aspects of fire pipe installation, and must be implemented in accordance with these specific fire pipe installation specifications when installing.

15 answers2024-06-22

Consumer water pipes are very important to maintain the safety of occupants, the standards are extremely high, and leaking water pipes need to be repaired immediately to avoid inevitable consequences. So what to do if the fire water pipe is leaking, and what is the standard of the fire water pipe, do you understand? Now let's take a look. >>>More

7 answers2024-06-22

Need to look at the place.

Building. Firefighting. Design Specifications. >>>More

7 answers2024-06-22

What is the form of fire pipe support and hanger? In the case of U-bolts, how big is the angle iron used for off-duty work? How much is used and what is the form of the stent?

3 answers2024-06-22

Here are some of the well-known brands recognized in the valve industry, which are widely recognized and have a high reputation. While rankings may vary depending on time and market conditions, the following brands are generally considered to be among the top brands in the valve industry: >>>More