  1. Anonymous users2024-02-12

    This situation should be caused by mechanical wear and tear inside the switch, and the switch should be removed and replaced separately, or the switch socket should be replaced as a whole.

  2. Anonymous users2024-02-11

    You can repair the structure as shown below, if the bottom hemispherical shape of the nylon sheet is worn, you can repair it with a mixed file or fine sand, and then apply some petroleum jelly on the bottom hemispherical surface and reinstall it.

  3. Anonymous users2024-02-10

    Turn off the power first, remove the screws (there may be a decorative cover to block it, pry it open with a slotted screwdriver), and take out the waterproof box. Install a new socket and follow the reverse steps. The principle of the wiring diagram of Schneider dual control switch is to control two electrical devices through the switch of two buttons, first connect the middle line post of one double control switch to the live wire, and connect the middle line post of the other double control switch to the lamp head.

    Circuit transformation, if the construction is improper, it is easy to have leakage, short circuit and other problems, not only to deal with it is very troublesome, and carelessly may also cause electric shock, fire and other accidents, to human life and family property to cause a great threat. Therefore, it is necessary to pay attention to the construction requirements of circuit transformation. The more small details are hidden, the more we can't take it lightly and think carefully when decorating, so as not to let the wires and sockets leave decoration regrets for staying.

  4. Anonymous users2024-02-09

    I had to change the switch. The reason is that the quality of the switch is not good, after plugging in the electric hot pot, the copper sheet of the socket is heated and burns out the base of the switch next to it, and the spring and rocker inside are stuck by the deformed base. Next time, just turn on the five-hole switch for a better one.

  5. Anonymous users2024-02-08

    k repair: he turned on the switch, and then the spring inside could be dropped, if the spring could be repaired, it would be repaired, and if it could not be repaired, it would be removed and connected directly.

  6. Anonymous users2024-02-07

    It's best not to dismantle, I won't There is no good way, if it is because you use too much electricity, more than the number of a of the plug board, it is to burn the switch soft, and you can't get it up if you don't take it apart. If it's not because the A number is too large, you can pick it up and slap it in the direction of your hand to see if you can come up. Generally, the plug-in board switch button flicks.

  7. Anonymous users2024-02-06

    Hello, you need to pay attention to safety when disassembling a five-hole switch, and turn off the power first. Then follow these steps:1

    Use a screwdriver to unscrew the screws on the cavity switch panel to remove the panel. 2.After removing the switch panel, you can see that there are two or four screws on the switch base, and use a screwdriver to screw these screws under the switch.

    3.Remove the switch base from the wall, being careful not to damage the wires. 4.

    After removing the switch base, you can see that there are connecting screws between the wire and the switch base, use a screwdriver to unscrew these screws to remove the wire from the switch base. 5.If the switch needs to be replaced, connect the new switch to the wire, and then install the switch by reversing the operation.

    It should be noted that care must be taken when disassembling the switch to avoid electric shock or short circuit. If you don't have relevant experience, it is recommended to ask a professional to do it.

  8. Anonymous users2024-02-05

    The five-hole belt opening is 4 terminals

    L1 switch live wire incoming line.

    L2 switch live wire outlet.

    n Neutral line. GND or three horizontal and one vertical is the ground wire.

    There are two ways to connect:

    1. Socket with switch: live wire connection L1, neutral wire connection N, flower wire grounding wire, L2 can be empty; The two wires you said are a live wire and a zero wire, and there is no buried ground wire, in this case, the live wire is connected to L1, and the neutral wire can be connected to N (please note that the socket without the ground wire will trip when it encounters a short circuit, and it cannot be protected if it leaks).

    2. The socket is often energized, and the switch is a lamp with a circuit: the live wire enters L2, the neutral wire is connected to N, the flower wire is connected to the ground wire, and L1 is connected to the fire to the light source (that is, the live wire connected to the lamp).

  9. Anonymous users2024-02-04

    Socket module: L-hole to live wire, N-hole to neutral wire, PE hole to grounding wire.

    Switch module: L-hole fire wire, L1 hole connection lamp control line.

    The neutral line of the lamp and the neutral line of the power supply are connected in parallel.

  10. Anonymous users2024-02-03

    The socket is wired separately from the switch, similar to the connection in the figure below

  11. Anonymous users2024-02-02

    If the switch is to control the light, there must be 3 wires, and if the switch is controlled, 2 wires are OK.

Related questions
10 answers2024-06-29

1. A binding post of the live wire access switch, and at the same time, a wire is drawn from this binding post to the L binding post of the socket. >>>More

9 answers2024-06-29

One: large-hole socket is also called high-power socket.

2: The high-power socket is a socket specially designed for the manufacture and use of high-power household appliances, which meets the configuration of 16 amperes (power 4000 watts), which can fully meet the bearing requirements of high-power electrical appliances. >>>More

22 answers2024-06-29

Five holes are opened.,It should be four wires, right?。。 A live wire, a neutral wire, a ground wire, a switch live wire to the light (no power). If there are two extra wires, it should be the switch live wire that controls the other two lights. >>>More

8 answers2024-06-29

1. How to wire a 5-hole socket? What do l, n, l1, and l2 connect to? The old electrician taught you.

6 answers2024-06-29

The first is as big as a big newspaper (people**), and the second is as big as folding the newspaper in half. The magazines we read are generally sixteen open.