Should the home cabling be slotted on the ground or on the wall? What are the advantages and disadva

Updated on home 2024-07-14
24 answers
  1. Anonymous users2024-02-12

    First of all, we know that the purpose of hydropower slotting is to protect the pipeline and avoid workers from walking back and forth during construction, and then damaging the pipeline, and slotting is a good protection for the pipeline. Secondly, we know that hydro grooving does not increase the ground height too much. But if there is no slotting, in order to hide the pipes, the ground will naturally be raised, which in turn will affect the height of the room.

    Finally, inside the tank, the pipes are fixed, preventing them from moving back and forth, making them safer. First of all, it goes without saying that slotting can damage some building structures.

    If the ground is not protected, it is not allowed to have grooves. Secondly, due to the construction of the wall of hydropower slotting, there will be a lot of labor costs and extend the construction period. What are the benefits of not opening and incising?

    more stable and safe flooring and house structures; The second is to reduce the construction cost of one trough. What are the disadvantages of not slotting? First of all, if it is not slotted, it is not conducive to on-site water and electricity protection, so in this case, it is best to protect both sides of the ** pipe with wooden boards; Secondly, the distance between the pipes should be controlled within 2 cm, and every additional 50 cm a pipe is stuck.

    The single project in the residential decoration should be based on the normal construction of the whole construction project, such as the door mold transformation, do not smash the wall first, and then the masonry master will carry out the wall transformation. Slotting and non-slotting in hydropower transformation also involve the following aspects of engineering.

    The specific analysis is as follows: Why is it necessary to excavate the ground after laying the pipeline? On the one hand, if the owner does not plan to lay tiles on the ground, laying power pipes after slotting can reduce the use of cement and sand in ground leveling construction and save labor costs.

    On the other hand, the wiring after slotting has reference value for electrician construction, which is beautiful and generous, and is "conducive to" the smooth acceptance of the owner.

    Finally, the ground flatness is high after slotting, and it is not easy to step on the broken pipeline material during construction. This problem does not exist in underfloor heating houses in northern cities, because there is underfloor heating, and if the slots can destroy the underfloor heating pipes. If there is no underfloor heating, slotting is also feasible, but as long as the gypsum layer can be opened, slotting can effectively reduce the thickness of the bricks, because the level of some houses is too poor, the horizontal point difference between the living room and the room is a few centimeters, and the height of the room can also be used reasonably to make a decision.

  2. Anonymous users2024-02-11

    I think the wall grooving should be chosen. The advantage is that it is easier to grasp the problem, it is easier to repair, it is easier to operate, the installation effect is better, and even if there is a problem, you can easily find the wiring. The disadvantage is that it is more common, which will affect the color of the front and cause some damage in the front.

  3. Anonymous users2024-02-10

    Grooves in the wall should be chosen. The advantage is that the effect is better, the connection is more convenient, and the maintenance is more convenient. The disadvantage is that the maintenance cost is more, and once there is a failure, it will be difficult to find the difficulty, which will affect the speed of maintenance.

  4. Anonymous users2024-02-09

    I think it's better to groove in the wall; Ground slotting may lead to cracks, easy to seepage, may be stepped on during construction, wall slotting will have a protective layer, relatively safe, but not easy to track.

  5. Anonymous users2024-02-08

    It should be slotted on the ground, the advantage of ground slotting is that it is more convenient and trouble-free, and the disadvantage is that the ground needs to be smashed when the line is damaged, and it is not easy to repair in the later stage. The advantage of wall slotting is that it is more convenient to maintain in the later stage, and the disadvantage is that the wiring is more complicated, and the cost of materials will continue to increase.

  6. Anonymous users2024-02-07

    1.If the wiring at home must be slotted, it is best to open it on the wall. Wall slotting should first follow the principle of "horizontal and vertical".

    In hydropower construction, the layout of pipeline slotting must be reasonably planned. Improper pipe slotting can puncture water pipes or wires. Laying conduits directly in the slotted load-bearing wall may affect the load-bearing structure of the house, which is a great safety hazard.

    "Above but not on the ground" means that, in general, it is better to go up on the top of the water pipe than on the ground. This is because if you go to the top, you don't need to slot, and it doesn't matter how your water pipes and wires are arranged.

    2.Finally, you can cover everything with a ceiling! However, because the socket and faucet are not too high, if you go to the top, you need to connect the water pipes and wires to a lower position on the wall, and there are more consumables.

    Remind everyone that if you encounter a beam when you reach the top, don't break it. Most of these beams have auxiliary load-bearing and shockproof functions, and once damaged, there will be a lot of safety hazards. For the safety of your family and neighbors, let the water pipes and wires go around the beams.

    3.The choice is naturally to walk the wall. In fact, because switches, sockets, and faucets are generally installed on the wall, there is no way to slot on the wall at all.

    However, it is important to note that long lines should never pass directly through a wall, as they may damage the load-bearing structure of the wall itself. Especially for the newly built wall after the demolition and reconstruction, the front wall will be scrapped if it is not right! According to the national standard, the length of the groove of the load-bearing wall and beam column shall not exceed 10 cm.

    Grooving is a very common practice, and some are done to save construction time.

    4.Many construction teams will choose to groove on the ground, but there is a premise, the ground cement screed is at least 7 cm, because the depth of the groove requires about 5 cm, without this thickness, you can't walk on the ground. Large area transverse grooving is not suitable.

    Horizontal slotting in the wall is extremely dangerous and not much different from demolishing the wall, so it is best not to do horizontal slotting when decorating. Remember that the slotting is 3 cm. Ground grooving requires a cement pour layer thickness of 3 cm, which means that when cutting to a depth of 3 cm, the steel bars and gravel concrete are not visible.

    If the developer has installed floor heating when handing over the house, the ground cannot be slotted.

  7. Anonymous users2024-02-06

    Ground slotting is the best, because if there is a problem with the wiring, the ground is easier to repair, and the difficulty of repairing is not very large, the cost is not very much, and it is more convenient when wiring.

  8. Anonymous users2024-02-05

    It is best to slot on the wall, because slotting on the bridge can reasonably plan the layout, will not affect the direction of the water pipes and wires, and there is no great safety hazard.

  9. Anonymous users2024-02-04

    It is better to make a groove in the wall, because the wall groove must follow the principle of horizontal and vertical.

  10. Anonymous users2024-02-03

    It is better to groove the wall, if there is a problem, it is more convenient to repair, and the safety is relatively high, and the ground groove is more troublesome, and there are also potential safety hazards.

  11. Anonymous users2024-02-02

    It is better on the ground, because it is easier to arrange the line on the ground and the wall, and it is very troublesome to dig a hole in the wall.

  12. Anonymous users2024-02-01

    The slotting of the home integrated wiring must be opened on the wall, but some places that need to be routed are opened on the ground, and most of them are opened on the wall, which is more reasonable.

  13. Anonymous users2024-01-31

    I think it is more appropriate to open it on the ground, because it is more convenient for the ground to be repaired, and if it is opened on the wall, it may cause fracture damage to the surrounding walls, which is not conducive to maintenance.

  14. Anonymous users2024-01-30

    The wiring is to be grooved in the wall, because the wall groove will be more convenient for later adjustments, and the cost of groove in the wall is also very low.

  15. Anonymous users2024-01-29

    Open on the wall, and doing so will give us something to block these places from people from seeing the flaws in these places.

  16. Anonymous users2024-01-28

    For Xiaobai, the decoration and arrangement of wires at home is certainly not very clear, when decorating, most of them understand that they want workers to decorate better, and many people will ask workers to install water and electricity, so that they will feel that the master is very level, but in fact, the wires are beautifully distributed? Is this really the right approach? Decoration should not be so slotted wiring, many people did not understand at the beginning, and only then did they know how impractical it was to move in.

    For professional electricians, they will never do this, horizontal and vertical in addition to making the wire cloth look good, and there is no other role, but also there are certain safety hazards, so when the home is clothed with water and electricity, it is best to remind the workers, do not only value the beautiful atmosphere, when wiring the need to turn the place on the turn, if there is no special situation, then it is best to walk in a straight line.

    For friends with a little decoration experience are known, the wires are basically buried in the wall or the ground, no matter how good the decoration is, then when the tiles or the floor are paved, it will be blocked, and you can't see whether it looks good.

    Some unprofessional workers will also open the wall of the home into a horizontal groove when wiring, this practice is wrong, it is very unsafe to put the wire into the horizontal groove, once the worker is found to do this, then he must be stopped to avoid danger.

    The best wiring method is to shorten the distance between the two wires, which can reduce the occurrence of some safety accidents, not to say that horizontal and vertical is good, it is best not to take the curve when wiring the wire, especially those places to turn, to let the worker minimize the turn, as long as you follow such a principle, there will be basically no problem.

  17. Anonymous users2024-01-27

    Don't pursue aesthetics too much, and carry out too much right-angle wiring, and it will be sealed with the floor in the later stage, it doesn't matter if it looks good or not. Cabling should be in a straight line to minimize potential safety hazards.

  18. Anonymous users2024-01-26

    You should find the place where you need to place the electrical appliances, go to the place of the switch, draw the direction of the line with a pen, and then use the slotting machine to slot.

  19. Anonymous users2024-01-25

    There are advantages and disadvantages to slotted cabling. Advantages: Beautiful and does not take up space to use. Disadvantages: Trouble to maintain in the future. The inspection line should be slotted, and the maintenance cost is expensive. Pay attention to grooving. Don't have too many corners. Try to make two points and one line the closest in a straight line.

  20. Anonymous users2024-01-24

    The general decoration chooses to groove the wires on the ground, and install the water pipe on the roof, which is easy to maintain, of course, the specific situation should be analyzed according to the actual situation.

  21. Anonymous users2024-01-23

    Try not to groove in the ground, the floor slab is very thin, so it is generally better to groove in the wall.

  22. Anonymous users2024-01-22

    This kind of thing should actually be fine, but it mainly depends on what kind of effect you want to present.

  23. Anonymous users2024-01-21

    Yes, but keep away from strong current pipelines, keep a distance of more than 30cm between the threading pipe and strong electricity, and keep a distance of more than 20cm from the panel. However, it is best not to groove on the ground, destroying the protective layer that the floor slab should have, although it is not waterproof, but it is easy to seep water after slotting. As long as the line pipe is walked, it is protected by cement around it to avoid stepping on it during construction.

    The wall can be slotted, but it is better to only make vertical slots and avoid horizontal slots.

    Depending on the condition of your site, such as tiles or solid wood floors, you can use the floor wiring. If it is a laminate floor, it is better to walk on the wall, because there is no keel under the laminate floor, and the height of the threading pipe cannot be reserved. The cost of wall wiring is generally high.

    It should be routed according to the needs of the weak current line construction drawings, and it should be opened on the wall, not on the ground. Conversely, what should be on the ground will not be on the wall. Therefore, the slotting of weak current can be done on the wall and the ground, but it must be slotted in accordance with the line construction drawings.

  24. Anonymous users2024-01-20

    Decoration should never be so slotted wiring, check-in is not practical, I really regret my home decoration early.

    Home decoration cloth wires, I believe many people do not understand, workers in the decoration, everyone wants them to look good, because some cloth wires will require horizontal and vertical, but in addition to good-looking, in fact, the effect is not big, and this can not appear that the master is very professional. Decoration should never be so slotted wiring, check in to know that it is a pit, regret that my family did not know earlier.

    Now professionals in the distribution of wires, will not choose horizontal and vertical such a method, although it looks beautiful atmosphere, but the advantages are not much, but it is also very dangerous, when the home is arranged with hydropower, it is best to remind workers not to blindly pursue beauty, hydropower wiring when you need to bend as much as possible, do not drag mud and water, it is best to walk in a straight line.

    In the past, when decorating the wires, most of the wires were buried in the ground or in the wall, and the decoration was arranged to be beautiful and beautiful, so you can only see the outside of the floor, and you will not see whether the wires are beautiful.

    Some unprofessional people will open a horizontal groove on the wall when laying wires, this method is not recommended to use, the wire is installed in such a horizontal groove, it is very unsafe, we must pay attention to the wiring, although it is only a small detail, but if it is wrong, it will cause very big trouble.

    The most correct wiring method, that is, the two points and one line straight line distance is the closest, can reduce a lot of safety accidents, the wire is not horizontal and vertical, the wire does not want to have too many curves, then it is best to take good precautions in advance, such as walking in a straight line, so that there will not be many curves, natural electricity will also follow a lot of safety, there are many small details of the wire, as long as it is handled, it is quite convenient to stay.

Related questions
3 answers2024-07-14

The integrated wiring system is the infrastructure of the digital information system for the construction of the intelligent office, and it is a structured wiring system that unifies the planning and design of all voice, data and other systems, providing information and intelligent material medium for the office, and supporting the comprehensive application of voice, data, and more in the future. This article shares some common formulas for integrated wiring, I hope it will be helpful to you. >>>More

7 answers2024-07-14

Since the two places have been connected, file transfer is not a problem, as for fax, you can buy a fax software, a fax machine, you can divide more than ten or twenty internal numbers! It's very practical, as long as the network is unblocked, it's no problem. >>>More

10 answers2024-07-14

The wall must be slotted, and the main concern is on the ground, and many of us don't know whether the ground should be slotted or not. >>>More

2 answers2024-07-14

Many people don't know what the integrated wiring system is, so let's introduce it below. >>>More

8 answers2024-07-14

To put it simply, it's one of the lines that undertakes the whole system, the trunk line, the backbone line, like your central nervous system, the subline is the line that branches from the trunk to the endpoints, like your neural pathway, the computer room is like the brain, and the five senses are like the endpoints, you see???