What s going on with the elevator fault display E41?

Updated on Car 2024-08-06
10 answers
  1. Anonymous users2024-02-15

    Look at the brand and model of the inverter or motherboard, and find the corresponding fault ** information.

    In the case of the Menak system, e41 is:

    The safety loop is disconnected.

    Failure level : 5

    Cause of failure: The safety loop signal is disconnected.

    Fault resolution.

    1. Check the switches of the safety circuit and check their status;

    2 Check whether the external power supply is correct;

    3. Check whether the action of the safety loop contactor is correct;

    4. Check the feedback contact signal characteristics of the safety loop contactor (normally open, normally closed);

  2. Anonymous users2024-02-14

    Look at what system, if it's a Menak system, e41 is:

    E41: Safety loop is open.

    Failure level : 5

    Cause of failure: The safety loop signal is disconnected.

    Fault resolution.

    1. Check the switches of the safety circuit and check their status;

    2 Check whether the external power supply is correct;

    3. Check whether the action of the safety loop contactor is correct;

    4. Check the feedback contact signal characteristics of the safety loop contactor (normally open, normally closed);

  3. Anonymous users2024-02-13

    Look at what inverter brand and model, find the corresponding fault ** information, if it is a Monak brand inverter system, E41 is:

    E41: Safety loop is open.

    The safety loop signal is disconnected.

    1.Check the switches of the safety circuit and check their status;

    2.Check if the external power supply is correct;

    Fault**: err41

    Fault Name: The safety loop is broken.

    Cause of failure: The open safety loop signal is disconnected.

    Fault resolution.

    Check the switches of the safety circuit and check their status;

    Check if the external power supply is correct;

    Check whether the action of the safety loop contactor is correct;

    Check the safety feedback contact signal characteristics (normally open, normally closed).

  4. Anonymous users2024-02-12

    Elevator fault **E41, follow the steps below to solve: Elevator E41 is a safety loop disconnection fault. Cause of failure:

    The safety circuit fault should be regarded as one of the most common failures in the elevator. The judgment logic is very simple, and if the voltage is not detected at the detection point, the fault will be reported. There are two types of detection:

    1. Low-voltage input point detection, the row of indicators on the left side of the motherboard, the input voltage is 24V, which is generally the normally closed feedback point of the detection contactor. 2. High-voltage input point detection, the position is at the bottom of the motherboard three high-voltage indicators, the input voltage is 110V, generally directly from the safety loop to separate a line, connected to the detection point. Solution:

    1. The safety circuit mainly includes: phase sequence relay, control cabinet emergency stop, speed limiter switch, traction machine turning switch, (no machine room traction machine emergency stop), car top maintenance box emergency stop, (through the door and back door emergency stop), safety gear switch, (no machine room car stop switch), underground pit emergency stop, pit emergency stop, rope wheel switch, buffer switch, upper and lower limit nuclear switch. 2 This fault is very simple, if the safety circuit is not broken, still report this fault, then pay attention to two points 1) whether the insurance is burned, whether it is the power supply of the safety loop is out of power 2) an unused point, the wrong set of parameters, is defined as the detection point 3 Because the emergency electric operation of the control cabinet can shield a part of the safety loop switch, digging the foundation so there will be a control cabinet maintenance can take the elevator, but the car top is repaired to report the fault, and the fault is reported after returning to normal.

  5. Anonymous users2024-02-11

    Pro-Elevator Fault**e41 means "Door motor overheating", this fault needs to be dealt with as follows:1Check whether the door motor and related motor control circuits have short circuit or grounding phenomenon, and if so, eliminate the short circuit fault first.

    2.Check whether the working environment temperature of the door motor is too high, if the temperature of the machine room is too high, you can reduce the ambient temperature first. 3.

    Check whether the setting parameters of the variable frequency drive of the door motor are correct, especially whether the acceleration and deceleration time and the upper torque limit are too large, resulting in the overheating of the door motor. It is necessary to adjust the inverter setting parameters to the appropriate range. 4.

    Check whether the fan and heat sink of the door bend are stalled or have poor heat dissipation, and clean them first if necessary to keep the heat dissipation normal. 5.Disconnect the power supply of the door motor, and manually move the door panel to check whether it is flexible and normal.

    If the movement of the door panel is not flexible, it means that there is a mechanical problem that causes the door motor to overheat and seep into the scene, and it needs to be repaired before the power can be turned on. 6.After confirming that there is no abnormality in the above problems, reset the elevator control system or power off for about 30 minutes before powering on, see whether the door motor continues to report the E41 overheating fault, if it continues to overheat the fault, it means that there is a problem with the door motor itself, and the door motor needs to be replaced before it can resume operation.

    7.Restore the elevator power-on operation, observe the working condition of the door motor and temperature changes, and confirm that the fault has been completely solved. If it works normally, the elevator can be restored to normal use.

    To sum up, to deal with the fault of E41 elevator, we should first eliminate external factors such as short circuit of relevant lines and excessive ambient temperature, and then check the internal causes of overheating caused by door motor control parameters and mechanical problems. Eventually, if the overheating fault cannot be resolved, the door motor will need to be replaced before it can fully resume operation. Continuous monitoring is required during the treatment process to confirm that the fault has been completely resolved.

  6. Anonymous users2024-02-10

    Summary. E41 fault** is: E41 Safety Loop Open Safety Loop Signal Down.

    Kissing should be handled as follows:

    1.Check the switches of the safety circuit and check their status;

    2.Check if the external power supply is correct;

    3.Check whether the action of the safety loop contactor is correct;

    4.Check the feedback contact signal characteristics of the safety loop contactor (normally open, normally closed);

    How to solve the new Shida elevator fault **E41.

    E41 fault** is: E41 safety loop disconnection The safety loop signal disconnection should be handled as follows: 1

    Check the switches of the full circuit of Ambu Yusun and check their status; 2.Check if the external power supply is correct; 3.Check whether the moving chain of the safety loop contactor is correct; 4.

    Check the false judgment characteristics of the feedback contact signal of the safety loop contactor (normally open, normally closed);

    Thank you for your trust, the above is my reply, I hope it can help you, I wish you a happy life Kiss can click on the upper right corner to end the consultation or continue to ask Oh, I hope to get Bu Heng's kiss of the praise ruler [than the heart] [than the heart] [than the heart] [than the heart].

  7. Anonymous users2024-02-09

    Summary. Hello dear<>

    <> elevator failure**E41 usually indicates that the elevator door lock is faulty, which may be caused by the following reasons:1Damage or mechanical obstruction of the door lock. 2.The door lock circuit is incorrectly wired or the component is failing. 3.The door lock control panel is faulty.

    How to deal with elevator failure**E41?

    Hello dear<>

    <> elevator failure**E41 usually indicates that the elevator door lock is faulty, which can be caused by the following reasons:1The mechanical parts of the door lock are damaged or the mechanical block blocks the excavation.

    2.The door lock circuit is incorrectly wired or the component is failing. 3.

    The door lock control panel is faulty.

    The processing method is as follows:1First, park the elevator on the nearest floor and make sure all passengers exit the elevator safely.

    Set up warning signs near the computer room to prevent others from misoperation, and prohibit others from opening the elevator door. 2.Determine the cause of the failure:

    Check whether the mechanical parts of the door lock are damaged or the mechanical blockage of Kainianzao, check whether the wiring of the door lock circuit is correct, and check whether the door lock control board is faulty. 3.If the door lock mechanical parts are damaged or the mechanical resistance is high, take the plug:

    It is necessary to replace the corresponding mechanical parts or remove obstacles and clean the mechanical parts. 4.If the door lock circuit is miswired or the component fails:

    It is necessary to check whether the door lock circuit is wired correctly and replace the damaged electrical components. 5.If the door lock control panel is faulty:

    The door lock control panel needs to be replaced. 6.After the fault is resolved, the elevator is restarted and if everything is in order, it can be restored to normal use.

    If the problem still exists, it needs to be further inspected or contacted by professional elevator maintenance personnel for treatment.

    It is important to note that before performing any type of elevator repair, it is important to take proper safety measures and strictly follow the operating instructions. If you are not sure how to carry out elevator repairs, please seek a professional technician or contact the elevator manufacturer's customer support service Zhenqing Chongwu Oh <>

  8. Anonymous users2024-02-08

    How to deal with elevator failure**E41? Dear, hello crack pie banquet, the troubleshooting methods are as follows: 1 Check the switches of the safety return silver road and check their status; 2 Check whether the external power supply is correct; 3. Check whether the action of the safety loop contactor is correct; 4. Check the feedback contact signal characteristics of the safety loop contactor (normally open, normally closed); 5.

  9. Anonymous users2024-02-07

    E45: The up and down deceleration switch is disconnected.

    Fault level : 4

    Cause of failure: When stopping, the upper and lower 1-level deceleration switches are disconnected at the same time; Forced deceleration action, the elevator will also prompt e45 after deceleration, but it will automatically reset after 2 seconds.

    Fault resolution.

    1. Check that the contact between the upper and lower level deceleration switches is normal;

    2. Confirm the characteristics of the upper and lower 1st deceleration signals (normally open, normally closed);

    Tips for using elevators:

    First, pay attention to the overrun overload elevator can not be overloaded, when the elevator alarm, you should take the initiative to exit, wait for the next trip and then ride, the elevator overload is very dangerous.

    2. Do not block the elevator door, when the elevator door is about to close, do not force into the elevator, prevent the elevator from closing, and do not stay with one foot inside and one foot outside, which will be injured and ambushed.

    Third, the round object does not press the emergency button casually, the emergency button is set up to deal with unexpected situations, the elevator is in normal operation, do not press the emergency button, otherwise it will bring you unnecessary trouble.

    Fourth, when taking the elevator, if the elevator door is not closed and runs, it means that the elevator is faulty, passengers should not take it, and at the same time report the design to the maintenance personnel.

    5. Before coming to the elevator, passengers first look to see if there is a "stop the elevator maintenance" sign. If the elevator is under maintenance, it should be hung with such a sign and passengers should not take it.

    What to do if the elevator fails, we must maintain a calm state of mind, so as to do a good job of alarm measures, and the finch cavity also needs to do a good job of maintaining the balance of the body, so that you can protect your body, these related content everyone needs to pay attention to. What are the tips for using the elevator, these related common sense can be used in life, and you can get good help and solve some problems when you encounter them.

  10. Anonymous users2024-02-06

    Look at what inverter brand and model, if it is a Monak inverter system, E04 is:

    E04 Constant velocity overcurrent.

    Cause 1: The output of the main circuit is grounded or short-circuited;

    2. Whether the motor has been tuned with parameters;

    3 The load is too large;

    4. The rotary encoder interferes greatly;

    E02 E03 E04 countermeasures.

    1. Check whether the output side of the inverter and the running contactor are normal;

    2. Check whether the power line is damaged on the surface and whether there is a possibility of short circuit to the ground. whether the connection is reliable;

    3. Check whether there is a copper wire at the terminal on the motor side;

    4. Check whether the inside of the motor is short-circuited or grounded;

    5. Check whether the star sealing contactor causes a short circuit in the output of the inverter;

    6. Check whether the motor parameters are consistent with the nameplate;

    7. Re-perform motor parameter self-learning;

    8. Check whether the brake is continuously opened before the fault is reported;

    9. Check whether there is any mechanical jamming;

    10. Check whether the balance factor is correct;

    11. Check whether the encoder wiring is correct and reliable. The asynchronous motor can try to run in the open loop and compare the current to determine whether the encoder is working properly;

    12. Check whether the number of pulses per revolution of the encoder is set correctly;

    13. Check whether the encoder signal is interfered with; Check whether the encoder traces are independently threaded through the pipe, and whether the cable distance is too long; whether the shield is grounded at one end;

    14. Check whether the encoder is installed reliably, whether the rotating shaft is firmly connected with the motor shaft, and whether it is stable in high-speed operation;

    15. Check whether the UPS feedback is valid when the UPS is not running; (e02)

    16. Check whether the acceleration and deceleration are too large;

Related questions
25 answers2024-08-06

The reasons for the failure of Siemens elevator E35 are as follows. >>>More

35 answers2024-08-06

In order to avoid the subsequent impact on your electricity consumption and billing, please reflect to the owner of the meter in a timely manner, if you belong to the electricity customer of Guangdong Power Grid, please call the 24-hour power supply service **95598, and the power supply company will arrange staff to follow up. >>>More

15 answers2024-08-06

Our consclousness is pleasant, from the cruelty of the elements, to the sophistication of devotion to our concept of God, until finally all things are seen to narrow the gap to the divinity stream, combing through the finite and infinite to its celebrations.

5 answers2024-08-06

Problems with the temperature sensor.

11 answers2024-08-06

- Is the air conditioner malfunctioning? With my 8 years of experience in repairing air conditioners, I will tell you how to solve these faults, which should save you a lot of detours. >>>More