-
No pain, no gain, think more The knowledge harvested is the real knowledge, and you can't ask the answer on the Internet.
Learning the basics of answering questions and mastering them is not a good way to see the answers.
-
If a motor is driven by an inverter, a ground fault will be reported for a period of time, but there will be no problem when starting the motor with a frequency of use.
There are several reasons for this:
1. When the power frequency is running, there is no higher harmonic, the current of the distributed capacitance to the ground is weak, and there is no leakage;
2. The insulation of the motor is not good, and the capacitance distributed to the ground is large;
3. When the PWM rectangular wave output by the inverter simulates sinusoidal alternating current, there are higher harmonics, and the current of the distributed capacitance to the ground is strong, and it is felt that there is serious leakage;
First, the voltage factor:
1) When the power supply voltage of the IGBT module is too high, it will exceed its safe working range, resulting in its breakdown damage;
2) When the power supply voltage is too low, the load capacity is insufficient, the running current increases, and the running motor is easy to produce stalled rotor phenomenon, which endangers the safety of the IGBT module;
3) The fluctuation of power supply voltage, such as the loss of DC loop filter (energy storage) capacitor, will cause the generation of inrush current and peak voltage, which will threaten the safe operation of IGBT module;
4) The control voltage of the IGBT - when the driving voltage is low, it will lead to the under-excitation of the IGBT, the internal resistance of the IGBT will become larger, the power consumption and temperature will rise, and the IGBT module will be easily damaged.
Second, the current factor:
1) Overcurrent, in the light and medium overcurrent state, is the anti-time protection area;
2) Severe overcurrent or short circuit state, no delay quick break protection;
3. Temperature factor:
1) Mild temperature rise, forced air cooling and other means;
2) When the temperature rises to a certain amplitude, stop protection;
Fourth, other factors:
1) The abnormality of the driving circuit, such as the interruption of the negative cut-off negative voltage control loop, will cause the IGBT to be damaged by false touch;
2) The control circuit and the detection circuit itself are abnormal, such as the reference voltage drift of the detection circuit, which leads to the change of the control point of the protection action, and cannot play the due protection role.
-
There are two possibilities for the inverter to report an error.
1. False alarm, inverter itself failure.
2. There is indeed some place to ground.
I don't know how your 'measured motor and its wiring are not abnormal' is detected, if you do use the shake meter to shake the motor and cable, there is no grounding phenomenon. Then it can only be a false alarm, after the reset to see if it can operate normally, if it is still grounded, then the inverter detects the fault and sends it for repair.
-
If the inverter reports a ground fault, the insulation of the inverter's output cable should be checked first, and then the insulation of the motor. If you block this function through the parameter settings, it will affect the start of the inverter.
-
The ground fault of the inverter is generally due to the igbt burning, or there is a problem with the trigger circuit, which causes the three-phase unbalance alarm, you check the IGBT module.
-
There are many causes of ground faults. You're going to rule out the damage of 1:IGBT.
2: The insulation value of the motor is enough. 3:
Is the cable in the inverter plugged in, 4: the possibility of bad current detection is also relatively large, and other components, you can rule it out.
-
Generally there is an impact, check the motor insulation, and then check the test circuit.
Save yourself from more trouble.
-
I don't know how much power the motor is? Is it compatible with the inverter?
If the motor is matched with the inverter, it means that the motor is wired incorrectly, and the triangle connection is connected into a star.
When the load becomes larger and the stall rotor is enlarged, the current does not exceed the allowable value of the inverter, which is the phenomenon.
Or the motor power is too small.
Not to mention LG, it is a domestic miscellaneous brand, the function of the inverter is also very perfect, if the motor and the inverter match, the motor wiring is correct, there will be no such low-level error.
-
You put the router according to your personal settings, you want to automatically dial and disconnect automatically.
-
4m broadband, is there anything wrong.
According to the design of the inverter, as long as the rated power of the motor is greater than or equal to the motor. Of course, if you choose one level higher than the motor power, the load margin of the inverter is larger, which is more beneficial to the operation of the inverter. However, the cost of the equipment will increase. >>>More
If you really want to study well, the first thing is to have a positive attitude; >>>More
Hello, I am also from Jiangxi, and your situation is similar, but the school I want to apply for is different, secondary school students can not participate in the college entrance examination, must be admitted to the junior college and then have a college graduation certificate and provincial level 3 English certificate and level 2 computing certificate, I just can't do so I went to take the college exam again, now I am a sophomore student, waiting for the college entrance examination after graduation, of course, you can also choose the same discipline of self-examination, undergraduate two majors at the same time to study and apply for the examination, so that you can get the college diploma before graduating from the bachelor's degree, You can directly take the undergraduate exam.,The latter method is what I only learned later.,But there's always no harm in studying more.,Now there's a big difference between finding a job and this one.,Personally, I think it's worth sacrificing your youth.,Hehe.。
Girls need to be reserved, but it seems that this boy is still very shy, and even if he likes you, he is embarrassed to say it. Does he usually care about you? Has it ever peeked at you? >>>More
Bank of China's 3-month fixed deposit and lump sum interest is, if you deposit 25,000, the 3-month interest is. >>>More