The reason why Chigo air conditioning is not refrigerated Six factors are indispensable

Updated on technology 2024-03-25
3 answers
  1. Anonymous users2024-02-07

    1. The voltage of the power supply is not enough.

    Solution: Maintain a normal supply voltage.

    2. The power of the air conditioner is not enough.

    Solution: Make the power space of the air conditioner and the cooling capacity required to match it.

    3. The external ambient temperature is too high.

    Solution: Change the environment in which the outdoor unit is used (move away from the high temperature environment or make the surrounding air of the outdoor unit more easily circulated).

    4. The copper pipe between the outdoor unit and the indoor unit is too long.

    Solution: Minimize the length of the copper tube between the outdoor unit and the indoor unit of the air conditioner.

    5. The air conditioner is not cleaned and maintained for a long time.

    Solution: Clean and maintain the air conditioner to make the clean outdoor unit more tolerant of heat dissipation.

    6. Freon is not enough (commonly known as not enough refrigerant).

    Solution: Supplementing freon can solve the problem of air conditioning not cooling.

    For details, please call us or make an appointment for maintenance.

  2. Anonymous users2024-02-06

    Reasons and solutions for Chigo air conditioning not refrigerating:

    1. There is not enough freon (also known as "refrigerant" is not enough).

    This is a normal situation, generally appears in the use of three to four years of old air conditioners, air conditioning is not completely not refrigerated, but the effect of refrigeration is not good enough, this is because the old air conditioners are used as freon refrigerant, long-term use will volatilize, in addition to improper installation caused by freon leakage and the machine itself problems.

    Solution, adding refrigerant can solve the problem of air conditioning not cooling.

    2. The voltage of the power supply is not enough.

    The power supply voltage is unstable, and it often fails to reach the normal voltage, especially during the peak of electricity consumption. Of course, this kind of problem is obviously not something that a skilled air conditioner maintenance master can solve, and we must start from the aspect of providing a stable voltage to solve the problem.

    The solution is to maintain the normal supply voltage.

    3. The power of the air conditioner is not enough.

    This is also one of the common reasons for not refrigerating, but there are many reasons for this kind of non-refrigeration, such as small power air conditioning pipes and large area of the room, and some although the air conditioning power and the room area seem to match, but because the room is relatively unsealed (such as doors and windows are wide open, etc.) or there is a heat source in the room (such as a lot of computers), of course, the glass room is also one of the heat sources, etc.

    The solution is to match the refrigeration capacity required by the power space of the air conditioner; change the conditions of the environment in which it will be used; increase the tightness of the jujube in the use environment; Reduce the heating source in the environment where the air conditioner is used to solve the problem of non-cooling.

    4. The external environment temperature is too high.

    This kind of non-refrigeration situation is common in our outdoor unit installed in a relatively closed space or the temperature around the outdoor unit is too high, so it is extremely easy to cause the heat emitted by the radiator to flow away due to the lack of air circulation in the small space where the outdoor unit is located, so that the air conditioner is not refrigerated; There is also a common saying that when the outdoor temperature exceeds 43 degrees, it is difficult for most air conditioners to transfer indoor heat to the outside through the radiator of the outdoor unit, which will also cause the air conditioner to not refrigerate.

    The solution is to change the environment in which the outdoor unit is used (move away from the high temperature environment or make the surrounding air of the outdoor unit more easily circulated).

    5. The air conditioner is not cleaned and maintained for a long time.

    Because the outdoor unit is installed outdoors, after a long time of use, the radiator will absorb a lot of dust, garbage and other dirt, so that the heat dissipation effect of the radiator is poor and the air conditioner is not refrigerated; In addition, ignoring the maintenance of the air conditioner for a long time will make the room air unhygienic, more susceptible to air conditioning diseases, increase power consumption, and shorten the service life of the air conditioner.

    The solution is to clean and maintain the air conditioner to make it easier to dissipate heat from a clean outdoor unit.

  3. Anonymous users2024-02-05

    1. The indoor unit or outdoor unit is not running.

    First of all, it is necessary to check whether the Chigo air conditioner is operating normally, including indoor units and outdoor units, especially to check the compressor of the outdoor unit, as long as one of them is not operating normally, then you have to ask professionals to repair it.

    2. The air filter is blocked.

    Due to the long-term use of the air conditioner, there is no regular cleaning to cause the filter to be blocked, and the sediment accumulates more and more for a long time, which eventually leads to the air conditioner not being refrigerated.

    3. Insufficient refrigerant for air conditioning.

    The biggest possibility is that there is no refrigerant or insufficient refrigerant in the Slim Air Conditioner, at this time we can ask professionals to come and add refrigerant.

    4. There is a problem with the power supply or voltage.

    Power supply or voltage problems are more common in summer, because in the hot summer electricity consumption is relatively large, seriously exceeding the electricity load, it will lead to air conditioning not refrigeration, in this case there is no better way to destroy the old, at most is to negotiate with the local property to increase the rated power of electricity, and then there is to buy a better voltage regulator.

Related questions
21 answers2024-03-25

Chigo air conditioner after-sales is super poor. I'm. I won't buy Chigo air conditioners in the future. >>>More

14 answers2024-03-25

It may be that freon is not enough, and adding freon can solve the problem; It may also be that the power supply voltage is not enough, and a household voltage regulator can be installed; It may also be that the power of the air conditioner is not enough, and the air conditioner with higher power can be replaced; It may also be that the external ambient temperature is too high and the installation environment of the outdoor unit needs to be replaced. 1.Freon deficiencies generally occur in old air conditioners that have been used for three to four years. >>>More

3 answers2024-03-25

Air conditioning is an indispensable part of modern life, air conditioning provides people with coolness, but at the same time, air conditioning is always on is also easy to cause diseases, such as "air conditioning disease", etc., need to be used with caution.

28 answers2024-03-25

1. Freon is not enough (commonly known as not enough refrigerant). >>>More

29 answers2024-03-25

It is mainly manifested as slow refrigeration or no refrigeration, especially some air conditioners that have been used for a long time, once this situation occurs, people's first reaction is: find a maintenance master to add fluoride! However, what the author wants to tell you is that the lack of cooling of the air conditioner is not necessarily caused by a lack of fluorine. >>>More