What is Closed Loop Control? What is Open Loop Control? What is Closed Loop Control? What is the dif

Updated on Car 2024-03-22
10 answers
  1. Anonymous users2024-02-07

    1. Closed-loop control is a basic concept of cybernetics. It refers to a control relationship in which the output of the controlled is returned to the input end as the control in a certain formula, and exerts control influence on the input and DAO inlet. In cybernetics, closed-loop usually refers to the feedback from the output to the input through a "side chain", the so-called closed-loop control.

    The purpose of closed-loop control is that the output feeds back to the input and participates in the re-control of the output, which is achieved through feedback.

    2. Principle: When the controlled object is affected by interference, and its realization state deviates from the desired state, the control subject will issue new instructions according to this deviation to correct the deviation and offset the interference. In the closed-loop control, because the control subject can find and correct the deviation of the operation of the controlled object according to the feedback information, it has a strong anti-interference ability and can carry out effective control, so as to ensure the realization of the predetermined goal.

    Most of the controls implemented in management are closed-loop controls, and the control principles used are mainly feedback principles. If we denote the input value by x, the output value by y, the function of the object by s, the control system that is, the role of the feedback system by r, and the deviation information by x, then we have: y=s(x+x)=s(x+ry)=sx+sry

    where CF is called the feedback factor or control parameter, which reflects the feedback function or control function of the closed-loop control system.

  2. Anonymous users2024-02-06

    Closed-loop control refers to a basic concept of cybernetics. It refers to a control relationship in which the output quantity as the controlled is returned to the input as the control in a certain way, and the control influence is exerted on the input. How the system is controlled with feedback.

    When the operator starts the system, the control information is transmitted to the controlled object through the system operation, and the status information of the controlled object is fed back to the input to correct the operation process and make the output of the system meet the expected requirements.

    Closed-loop control is a more flexible and high performance control mode, and most of the control methods in industrial production adopt the design of closed-loop control.

  3. Anonymous users2024-02-05

    Hello, the closed loop is with feedback.

  4. Anonymous users2024-02-04

    1. Open-loop control refers to the system control mode without feedback information. When the operator starts the system and puts it into operation, the system will input the operator's instructions to the controlled object at one time.

    2. Closed-loop control refers to a basic concept of cybernetics. It refers to a control relationship in which the output as a controlled is returned to the input as a control in a certain way, and the control influence is exerted on the input.

    3. The difference between open-loop control and closed-loop control: whether there is feedback or not; Whether or not it is working on the current control. Open-loop control is generally a control activity that is completed in an instant, and closed-loop control will last for a certain period of time, which can be judged.

  5. Anonymous users2024-02-03

    1. Concept.

    Closed-loop control is a fundamental concept of cybernetics. Refers to a control relationship that returns to the input terminal as a control output in some way, and exerts control influence on the input. For example, a fully automatic washing machine, when the washing machine is refilled, it has an infrared sensor to scan the water level.

    When the water level is appropriate, the washing machine will stop automatically refilling water.

    Open-loop control does not require the input of the output change signal. Manual control is generally open-loop control, such as manual switch speed control, and the actual speed does not return.

    2。Difference: To put it simply, open-loop control, closed-loop control, the difference is just one point: whether there is feedback or not. There is no open-loop, there is a closed-loop one.

    Open-loop and closed-loop are both terms that are often used in terms of control. Open-loop control is the control without a feedback system, for example, the dimming table lamp you use at home, the knob is adjusted to**is**, and you can adjust it again if you don't feel right.

    Closed-loop control, generally set goals by people, and feedback detection data by the circuit's own detection circuit. The process of operation to achieve the tracking setting is called closed-loop control.

    For example, the air conditioning system of your own home is a closed-loop control, and the advanced one detects the indoor temperature in the remote control handle to make a relatively large closed-loop control. **Air conditioners need to use a higher level of closed-loop control to maintain a uniform temperature in several parts.

  6. Anonymous users2024-02-02

    Closed-loop copy control is a fundamental concept of cybernetics. It refers to the DU as the output of the accused and returns to the DAO as the control in a certain way

    An input and a control relationship that exerts control influence on the input. For example, when the automatic washing machine is filled with water, there is an infrared sensor in it that scans the water level, and when the water level is suitable, the washing machine automatically stops adding water.

    Open-loop control does not need to take the output change signal to control the input quantity. Manual control is generally open-loop control, such as manually converting the fan gear to achieve speed control, without feeding back the actual speed.

    To put it simply, there is only one difference between open-loop control and closed-loop control: there is no feedback. There is no open-loop, there is a closed-loop one.

  7. Anonymous users2024-02-01

    There is no feedback link in the open-loop control system, that is, the results of its control will not come back to affect the current control system; However, there is a feedback link in the closed-loop control system.

  8. Anonymous users2024-01-31

    The environmental control device refers to the detection and feedback device, the open loop does not have a detection device, the accuracy of the workpiece is poor, the semi-closed loop has detection and feedback in a single direction of processing, the accuracy of the workpiece is generally closed-loop, and the workpiece accuracy is detected and fed back from time to time in the process of workpiece processing, and the accuracy of the workpiece is relatively high.

  9. Anonymous users2024-01-30

    That is, this is to enter the professional knowledge, the general switch controls the live line, not the neutral line.

  10. Anonymous users2024-01-29

    A closed-loop control system is a type of control system. The specific content refers to: part or all of the output of the control system is sent back to the input end of the system through a certain method and device, and then the feedback information is compared with the original input information, and then the result of the comparison is applied to the system for control, so as to avoid the system from deviating from the predetermined vertical standard.

    An automatic control system based on the principle of feedback. The so-called feedback principle is to control according to the information of changes in the output of the system, that is, by comparing the deviation between the system behavior (output) and the desired behavior, and eliminating the deviation to obtain the expected system performance. In the feedback control system, there is not only a signal forward path from input to output, but also a signal feedback path from the output to the input end, and the two form a closed loop.

    Therefore, the feedback control system is also called a closed-loop control system. Feedback control is the main form of automatic control. The automatic control system is a feedback control system.

    In engineering, the feedback control system that keeps the output and the expected value in operation is often called the automatic adjustment system, and the feedback control system used to accurately follow or realize a certain process is called the servo system or follow-up system.

    Millions of car purchase subsidies.

Related questions
10 answers2024-03-22

The closed-loop of marketing is based on the four major links of product development, brand communication, channel construction and after-sales service to form a complete circular closed loop, and deeply grasp the user's habits and needs in the interactive communication with users, so that marketing is not only a process of selling goods. To put it simply, it is to carry out marketing to consumers in all aspects of the product, and constantly improve the possibility of users choosing the product again, so as to form a closed-loop marketing chain, and improve user satisfaction and trust through each cycle. >>>More

7 answers2024-03-22

See Computer Science and Technology Textbook Computer Networks, Fourth Edition, by Xie Xiren.

4 answers2024-03-22

All behaviors are inseparable from the subconscious, not that the subconscious cannot see or touch, but whether you are willing to touch it.

9 answers2024-03-22

Introduction: Material control is the supervision and management process of material requisition, receiving, material issuance and use according to the material plan. So, the question is, how to control materials in production? >>>More

5 answers2024-03-22

1. PWM control is also known as pulse width modulation.

2. The pulse width modulation mode is an analog control square spine pants type, which uses the digital output of the microprocessor to control the analog circuit, and modulates the bias of the transistor base or MOS tube gate according to the change of the corresponding load, so as to realize the change of the on-time of the transistor or MOS tube, so as to realize the change of the output of the switching regulated power supply. >>>More