Air conditioner installation specifications and precautions.
1. Installation standardsAccording to the national air-conditioning installation standards issued by the State Bureau of Quality and Technical Supervision, air-conditioning installation standards are specially formulated: 1Air conditioners should be installed in places that are not easily accessible to children.
2.Try to avoid places with poor natural conditions (such as heavy oil smoke, strong sandstorms, direct sunlight or high temperature heat sources). 3.
Try to shorten the degree of connection between the indoor unit and the outdoor unit. 4.Avoid places where artificial strong electricity and magnetic fields directly act, especially when it comes to the personal safety of consumers, the standard puts forward strict quantitative requirements.
5.The carrying capacity of the outdoor unit mounting frame shall not be less than 180 kg. 6.
Outdoor units of air conditioners should not be installed in common areas such as corridors, stairs, and exits inside buildings. 7.The outdoor unit of the air conditioner should not occupy the public sidewalk, and the distance between the bottom of the mounting frame and the ground of the air conditioner installed along the buildings on both sides of the road should be greater than meters.
8.The outdoor unit of the air conditioner should be as far away as possible from the doors, windows and green plants of the adjacent party, and the distance from the doors and windows of the other party should not be less than 3 meters. Second, the installation specification 1
Check the power supply voltage, wire material and wire diameter, power supply insurance size, socket quality, withstand voltage, and performance. 2.Check whether the specifications of the indoor and outdoor units are consistent, and whether the indoor and outdoor units and installation accessories are complete and effective.
3.Check the appearance of indoor and outdoor units for damage. 4.
Turn on the power of the indoor unit, use the remote control to convert the function, and check whether the machine operation and noise and the remote control are normal. 5.The pipeline has fixed points every two meters.
If the connecting pipe needs to be self-matched, the copper pipe should be matched according to the wall thickness specified by the manufacturer. 6.When installing indoor and outdoor units, attention should be paid to the level, the height of the indoor unit should not exceed 3 cm, and the outdoor unit should be as horizontal as possible, and the maximum height of the left and right units should not exceed 3 cm.
If the accessories need to be purchased by themselves, they shall not be lower than the standards specified by the manufacturer. 7.There shall be no less than 6 fixing screws for indoor units, no less than 4 fixing expansion bolts for outdoor racks, and gaskets and spring pads for outdoor expansion bolts, and the specifications and quality shall not be lower than those specified by the manufacturer.
There shall be no less than 4 anchor bolts for the outdoor unit. All bolts and nuts must be tightened. In case of loose walls, nails should be pierced or other corresponding measures should be used to fix them.
And ensure that the fixed life of the indoor unit and the outdoor unit is more than 20 years. 8.The power cord used must meet the quality standards and specifications specified by the manufacturer.
It is never allowed to use miscellaneous brands, loss parties, inferior power cords and signal lines, the power is below 1500W, the 10A cutout is selected, the 15A cutout is used from 1500W to 2500W, the 20A cutout is used at 2500W to 3500W, and the 30A cutout is used at 3500W to 6000W. 9.The exposed part of the outdoor pipe should not be longer than 20 cm, and care should be taken in the process of finishing the pipe to minimize the deformation of the copper pipe and avoid air flow noise.
10.After the installation is completed, the indoor unit is tested to ensure that the air conditioner has smooth drainage. 11.
The trial operation must reach more than 30 minutes, and check the various operating states that can be run, whether the parameters meet the regulations, and whether the various functions are perfect.
-
If you want to install an air conditioner, you must first put all the things in the air conditioner together and install them in order.
-
Well, in fact, there are many kinds of air conditioning installation specifications, such as the first one is paying attention to safety, and the second is to pay attention to the installation of wallpaper in safety mode.
-
Legal analysis: 1. Determine the installation location of the air conditioner.
The indoor unit of the air conditioner should be at a certain distance from the top of the room and the walls on both sides, and the distance should be more than 15cm to prevent air circulation from being blocked. When choosing the location of the indoor unit, it is necessary to consider choosing a place with easy drainage and can be connected to the outdoor unit's pipeline; Choose a place below where there are no valuables such as TVs and computers, and where the air outlet does not blow directly into the bed.
2. Determine the installation location of the air conditioner.
Maximize the cooling and heating effects of air conditioners; Minimize adverse effects such as noise, vibration, condensation, hot and cold air, etc.; Safe, firm and easy to maintain; Outdoors as close as possible to the indoor unit; The ventilation is good, and there should be a certain amount of space in the front and back, left and right of the external unit; Do's avoid direct sunlight and, if necessary, wear a sun visor without obstructing air circulation; Avoid places with heavy oil smoke, wind and sand, poor heat dissipation or high temperature heat sources; Avoid places where flammable gases are easy to leak and have strong corrosive gases; Avoid places with high salt content, hot springs, and places where sulfur gases are present, such as the seaside; Meet different brands and avoid other places with air quality problems.
Legal basis: Article 1191 of the Civil Code of the People's Republic of China Where the staff of an employer causes damage to others due to the performance of their work tasks, the employer shall bear tort liability. After the employer bears tort liability, it may seek compensation from the employee who has intentionally or grossly negligently.
During the period of labor dispatch, if the dispatched staff member causes damage to others due to the performance of work tasks, the employing unit accepting the labor dispatch shall bear tort liability; If the labor dispatch unit is at fault, it shall bear the corresponding responsibility.
-
1. The air conditioner should be installed in a place that is not easily accessible to children;
2. Try to avoid places with poor natural conditions;
3. Try to shorten the length of the connection between the indoor unit and the outdoor unit;
4. Avoid places where artificial strong electricity and magnetic fields directly act, especially in terms of personal safety of consumers, the standard puts forward strict quantitative requirements;
5. The bearing capacity of the outdoor unit mounting frame shall not be less than 180 kg;
6. The outdoor unit of the air conditioner should not be installed in the corridor, staircase, exit and other public places inside the building;
7. The outdoor unit of the air conditioner should not occupy the public sidewalk, and the distance between the bottom of the air conditioner and the ground should be greater than one meter from the bottom of the air conditioner installed along the buildings on both sides of the road;
8. The outdoor unit of the air conditioner should be as far away as possible from the doors and windows and green plants of the neighboring party, and the distance from the doors and windows of the other party shall not be less than 3 meters.
Legal basis: Article 5 of the Administrative Measures for Residential Interior Decoration and Decoration.
The following behaviors are prohibited in residential interior decoration activities:
A) without the original design unit or the design unit with the corresponding qualification level to put forward the design plan, change the main body of the building and load-bearing structure;
2) Changing rooms or balconies without waterproof requirements into bathrooms and kitchens;
3) Expand the size of the original doors and windows on the load-bearing wall, and remove the brick and concrete walls connecting the balconies;
4) Damage the original energy-saving facilities of the house and reduce the energy-saving effect;
5) Other behaviors that affect the safety of building structure and use.
The main body of the building in these measures refers to the structural structure of the building entity, including roofs, floors, beams, columns, supports, walls, connecting joints and foundations.
The load-bearing structure referred to in these measures refers to the main structural components and its connecting joints that are directly transmitted to the foundation with its own weight and various external forces systematically, including load-bearing walls, poles, columns, frame columns, piers, floor slabs, beams, roof trusses, suspension cables, etc.
-
1. The materials, specifications, partitions, wall thicknesses of the main materials such as copper pipes, water pipes, and thermal insulation materials used in the installation process, and the section steel, nuts, bolts and other auxiliary materials used to fix the base and bracket of indoor and outdoor units must meet the requirements specified in the installation instructions of Daikin air conditioners, and the auxiliary materials used for installation are flame retardant or non-combustible products as far as possible.
2. In order to ensure the actual piping length, equivalent piping length, and height difference between indoor and outdoor units, indoor and indoor units, the selection of piping lengths, refrigerant branches and piping after branches must be carried out in strict accordance with relevant regulations.
3. The direction of copper pipes, water pipes, signal line pipes, and power line pipes should be as horizontal and vertical as possible for aesthetic appearance.
4. The spacing of the copper tube fixing bracket is less than or equal to, and the bending radius of each specification coil shall not be less than its minimum bending radius, otherwise the cross-sectional area of the copper tube will become smaller, affecting the flow rate and flow rate of the refrigerant.
5. The branch joints in the refrigeration circuit are only allowed to be installed horizontally or vertically, and are not allowed to be placed sideways or obliquely, otherwise the flow direction of the refrigerant will be affected due to the weight of the refrigerant itself, and then the use effect will be changed.
-
It's a little too written! The main air conditioner should not blow on the bed as much as possible, and the air conditioner connecting pipe should be tightly connected and not leak! The indoor unit should be installed level (if it is uneven, the condensate will leak out from the low side), and the water pipe should be sloped (the air conditioner should be a little higher or horizontal than the drainage hole)!
The outdoor unit is OK if it is firmly installed!
-
1. The installation position of the outdoor unit should meet the following requirements: (1) The ground or wall should be able to withstand the weight of the body and vibrate; (2) The installation part should be easy to operate, adjust and maintain; (3) The noise, cold (hot) air and condensate generated during the operation of the external unit shall not affect the work, study and life of others; (4) There should be no flammable gas leakage and non-flammable materials around the external machine; (5) The external unit should be installed in the back place as much as possible. 2. The installation position of the indoor unit should meet the following requirements:
1) Avoid direct sunlight on the unit, away from heat source; (2) The air inlet and outlet of the internal machine should not be obstructed.
-
1. The installation position of the outdoor unit should meet the following requirements:
1) The ground or wall should be able to withstand the weight of the body and vibrate;
(2) The installation part should be easy to operate, adjust and maintain;
(3) The noise, cold (hot) air and condensate generated during the operation of the external unit shall not affect the work, study and life of others;
(4) There should be no flammable gas leakage and non-flammable materials around the external machine;
(5) The external unit should be installed in the back place as much as possible.
2. The installation position of the indoor unit should meet the following requirements:
1) Avoid direct sunlight on the unit, away from heat source;
(2) The air inlet and outlet of the internal machine should not be obstructed.
-
Hello, air conditioner outdoor unit installation requirements, hello! We're happy to answer your questions! Air conditioner installation requirements and specifications 1, the outdoor unit is installed on the reserved air conditioning board, or the location required by the property.
2. The outdoor unit requires that the upper and lower households can be smooth in the vertical direction. 3. The condensate pipe of the air conditioner should be inserted into the condensate interface of the rainwater pipe. 4. The outdoor unit outlet pipeline is uniformly arranged on one side of the air-conditioning board according to the requirements of the property, and the upper and lower households are straight and in the same position.
The opening position of the outdoor unit on the first floor of the outdoor unit outlet pipeline wall is required to be not less than 15 cm from the roof of the garage and the waterproof layer shall not be damaged. 5. The installation of the outdoor unit of the air conditioner should be firm, and the exterior walls of each building in the community are made of thermal insulation layer, which requires that the air conditioning board is fixed, and the length of the fixing bolt is not less than 12 cm (the depth of the structural layer is 7 cm).
Adopt pylons to fix, and the length of pylons fixing bolts is not less than 20 centimeters (depth into the structural layer is 12 centimeters) and the number of fixing bolts is not less than 2. , there are waterproof practice parts, fixed hangers, etc. shall not destroy the waterproof layer. 6. Fixing the bolt holes, and the pipeline through the wall holes should be waterproof and closed.
The bolt hole is closed with glass glue before the screw, and the wall hole is tightly plugged with waterproof oil sludge and then installed with a special cap.
-
Air conditioning installation requirements and specifications must first find a professional to install, and secondly, choose a relatively open place to put it, because its radiation is relatively large, and he must be given space to circulate. Thirdly, it is better not to install it in front of people.
-
Air conditioning installation requirements and specifications, first of all, you unpack to see if the air conditioner is damaged, and then find a professional installation master to install it for you.
-
Air conditioner installers will definitely undergo strict training before taking up their posts, and there are certain specifications for each brand of air conditioner installation.
-
The installation of air conditioners should pay attention to safety and stability, and be safer on the basis of ensuring normal operation.
-
The installation requirements and specifications of air conditioning are implemented in the installation specifications of the petroleum air conditioning industry.
During the installation of air conditioners.
Legal analysis: water tube boiler (GB T instead of GB T 16507-1996, compared with it, the main technical changes are as follows: water tube boiler and shell boiler are divided into two independent standards, water tube boiler is GB T 16507, shell boiler is GB T 16508;The standard of water tube boiler is divided into 8 parts, such as general principles, material banquet and dry Zen, structural design, strength calculation of pressure elements, manufacturing, inspection, test and acceptance, safety accessories and instruments, installation and operation; It stipulates the qualifications and responsibilities of manufacturing units, users and installation units; The scope of the boiler is defined; The allowable stress of steel bolt materials has been added. Added requirements for installation and operation; Increased requirements for energy conservation and environmental protection. >>>More
Midea's air conditioner installation work order is a work order placed by Midea, an installer assigned by the store. When you install, you can get it before installation as long as you add a work order.
The location of the outdoor unit is relatively good, always under the window or on the side. >>>More
Blow better in the direction of your feet, and feel the wind on your face. If it is already installed at the foot of the bed, use a mosquito net to block the direct wind. You can also move the deflector to the left and right, so that the wind will blow left and right. >>>More