Common faults and solutions of water purifiers.
Diagnosis and solution of common faults of water purifier.
1. The high-pressure pump cannot be used to make water if it does not start.
Check if there is a power outage and if the plug is plugged in properly.
Check if the low-voltage switch is out of order and cannot be connected to the power supply.
Check whether the high-voltage switch or water level controller is out of order and cannot be reset.
Check whether the transformer and fuse are burned.
Second, the high-pressure pump works normally but cannot produce water.
The high-pressure pump loses pressure.
The pre-filter element is clogged (no pure water wastewater or small wastewater).
Check valve blockage (with wastewater, no pure water).
The solenoid valve is out of order and cannot be opened effectively.
Whether the RO membrane is clogged or not.
3. The high-pressure pump does not stop.
The pressure of the high-pressure pump is insufficient and cannot reach the set pressure.
The check valve is blocked, and pure water is not produced (there is waste water but no pure water).
The high-voltage switch fails and cannot take off.
The solenoid valve is out of order and cannot be opened effectively.
Fourth, the high-pressure pump is shut down but the wastewater does not stop.
The solenoid valve is out of order and cannot effectively cut off the water.
Inspection method: close the pressure barrel ball valve, if there is still wastewater, it can be concluded that the solenoid valve is out of order) There is also a situation, close the water inlet solenoid valve and then open, if the machine is normal, then determine that the water pressure is too high, resulting in the solenoid valve can not be closed flexibly, then consider adjusting the water inlet to reduce the water pressure).
Check valve pressure relief, (waste water is very small) (inspection method: close the inlet solenoid valve, if there is still wastewater, it can be concluded that the check valve is pressure relieved).
Fifth, after the water is full, the machine repeatedly jumps.
Insufficient raw water pressure.
Check valve relief
The high-voltage switch is out of order.
There is pressure relief in the system.
6. The pressure barrel is full of water but the pure water cannot flow out.
Pressure drum depressurization.
Post-activated carbon clogging.
Whether the pressure barrel ball valve is damaged.
7. Insufficient pure water flow.
The pre-filter is clogged.
The pressure of the high-pressure pump is insufficient.
RO membrane blockage.
The wastewater ratio is out of balance or the flushing switch is not closed tightly.
8. The ratio of pure water to wastewater is seriously out of balance.
Check the flushing solenoid valve for damage.
Check that the wastewater proportioner is not clogged or too conductive.
Check if the RO membrane is clogged or the removal rate is severely reduced.
9. The machine is constantly flushed.
Waste water is not tighter than failure or flushing start.
10. Loud noise.
Check whether the raw water pipeline is cut off, causing the booster pump to run dry, resulting in the noise of the water purifier.
Check whether the raw water is normal, and if it is a towerless water supply, whether there is gas in the water.
Check whether the booster pump is faulty, the vibration is too large, there is a friction sound, etc.
Check whether the water purifier is placed securely.
Check if the water pipe is too long, and the vibration of the pump makes the water pipe tap on the casing.
Check if the hot water is boiling and causing excessive noise.
Check if the compressor is normal.
Ten. 1. Water leakage.
Check the water purifier waterway and find the leakage point.
Check the small Unicom for water leaks.
Check the water dispenser for leaks.
If the water leak is very small and not easy to check, it can be used for dry facial tissue testing.
-
Summary. 1.First, turn off the power of the natural water purifier, unplug it and cut off the water supply.
2.Open the case and check whether the water connection part in the body is loose or aging. If a problem is found, make appropriate adjustments or replacements.
3.Check if the filter element in the machine needs to be replaced. If the life of the filter has expired, it may cause poor flow of water or poor water quality, which can affect the normal operation of the machine.
4.Check that the water pipes have fallen off. If the connection to the water pipe is loose or in poor contact, the flow of water and the purification effect will be affected.
Please double-check that the connection of the water pipe is secure and reconnect. 5.Reassemble the machine and power it back on, follow the instruction manual.
If it still does not work, it is recommended that you contact the after-sales service center for further assistance.
1.First, turn off the power of the natural water purifier, unplug it and cut off the water supply. 2.
Open the case and check whether the water connection part in the body is loose or aging. If it is found that the question is in Chisui Town, the appropriate segment will be adjusted or replaced. 3.
Check if the filter element in the machine needs to be replaced. If the life of the filter has expired, it may cause poor flow of water or poor water quality, which can affect the normal operation of the machine. 4.
Check that the water pipes have fallen off. If the connection to the water pipe is loose or in poor contact, the flow of water and the purification effect will be affected. Please double-check that the connection of the water pipe is secure and reconnect.
5.Reassemble the machine and power it back on, follow the instruction manual. If it still does not work, it is recommended that you contact the after-sales service center for further assistance.
In short, poor water contact with a good natural water purification mechanism may lead to problems such as poor waterway circulation, poor water quality, and reduced filtration effect, which need to be investigated and solved in time. If you can't solve the problem, it is recommended that you consult a professional or contact after-sales service<>
-
Hello dear, glad to answer for you, <>
The treatment measures for poor water contact of the natural water purification mechanism are as follows: 1. Check the pipeline of the water purifier and straighten out the pipeline of the water purifier. 2. Check the power supply of the water purifier, turn on the alternating current of the water purifier, if the input power supply of the water purifier is normal, check the output voltage of the transformer shed.
3. Check whether the high-voltage switch or float switch is out of order and cannot jump back. 4. Check whether the water inlet solenoid valve is normal. Unscrew the water outlet of the solenoid valve, turn on the power supply, check whether the water is connected, if not, transfer to the next step of detection.
5. Open the raw water ball valve to detect whether the filter element in front of the reverse osmosis membrane is blocked, such as plugging and replacement; If water is passed, the solenoid valve is damaged. 6. Check whether the amount of wastewater discharge is too large, so that the proportion of pure and wastewater is out of balance. 7. Check whether the rear activated carbon filter is blocked.
Thank you for your consultation, I hope this service can help you, you can click on my avatar to follow me Xiangran, and if you have any questions in the future, please consult me again. I wish you a happy life, a happy family, good health, and all the best <>
-
1. The effect is weakened and affects the health of the body.
The clogged filter element not only reduces the effluent flow, but also may weaken the filtration effect, resulting in a reduction in the "purity" of the purified water, and some harmful impurities may be absorbed into the body if the consumer still drinks directly.
Let your body act as a "filter". 2. Overload and waste of invested funds.
-
What is the reason for the water purifier to produce less water or no water?
I haven't heard of a natural brand, and it may be a new brand. >>>More
Ozone machine, which one is better? --Purely two types of things, water softener and water purifier, both can be filtered, but in terms of sterilization ability, durability and daily maintenance, it is absolutely incomparable with ozone machine, and it is easy to cover other things on the filter element. Of course, ordinary ozone machines cannot remove some impurities in the water because they do not have a filtration function! >>>More
I have been engaged in the water purification industry for many years, drinking water series, in addition to using RO reverse osmosis water purifier there is no other way to completely remove water alkali and ensure water safety, you know about Wanjiayuan, your home in the north, want to drunk water alkali is larger, if you want to solve the problem of drinking water for your family, you can only install a pure water machine, not 3000 yuan so expensive. In addition, you must know that there is no ultrafiltration machine that can solve the scale problem, let alone believe in magnetization and ionization.
Look at the concept of water purifier, if some minerals are retained, it is fine, because a large part of the minerals in the human body are ingested through water, and the intake from food alone cannot be satisfied. If the mineral content in the water is low or even none, then you should usually supplement with mineral tablets. >>>More
There is no way to do this, a friend of mine is in Anhui Onggemali to do Meiling water purifier after-sales, he told me that if you waste water, this is unavoidable, this has a lot to do with the local water quality, the water quality is good, the waste is less, and vice versa. All of them will be produced by water, but there is no way to do this, and there is no good solution Hehe, I hope it will help you, remember, dear.