10 answers
  1. Anonymous users2024-02-07

    The reasons for all electrical appliances to be unplugged and tripped: there is a short circuit or leakage in the indoor wiring and damage to the switch itself.

    The mechanical failure or electronic failure of the switch itself can cause the phenomenon of automatic tripping or failure to close. For example, when the electronic tripping device components in the switch are damaged, the detection circuit may output an abnormal signal, and after amplification, the tripping mechanism is pushed to cut off the power supply, that is, tripping.

  2. Anonymous users2024-02-06

    Is there only one circuit breaker control of the electrical appliances at home, if you can first remove all the wires at the lower end of the switch, and then connect back a circuit by loop, and close the switch once every loop, when it jumps is that the circuit has a problem, and then check the socket or lamps of the circuit one by one, if there is no problem, I think the socket line is the most likely to break the skin, in that case, if the line of the home cloth has a ground wire, you can replace the ground wire as a live wire or zero wire, Otherwise, let's install the line openly.

  3. Anonymous users2024-02-05

    After pulling down all the brakes, use the multimeter * 1k gear to zero live wire resistance to the ground, if there is resistance, the line is aging or broken, if there is no problem, the gate may be broken.

  4. Anonymous users2024-02-04

    Look at the socket closest to the place where there is water in your house, there is a big problem there, if you have a little leakage and can touch a little water, it must be a jump. It is easier to get water up by focusing on the shower in the bathroom. There are also suggestions from other big brothers.

  5. Anonymous users2024-02-03

    Try changing the switch.

    I really can't do it, find an electrician. Our household electricity is strong electricity, please electrician special solution.

  6. Anonymous users2024-02-02

    That is, there is a problem with the line.

  7. Anonymous users2024-02-01

    Dear, the socket circuit takes a period of time to trip the reason: there are generally two situations, one is leakage tripping, and the other is overload tripping. 1. There are many household appliances on the socket line at home, and part of the current load is generated during normal operation, and the current tolerance of the line itself is limited, and when the trip current limit is reached, the trip situation will occur.

    2. If you usually don't jump and when you use an electrical appliance, it will trip or it is easy to trip, it means that the appliance has a leakage place or a place with poor insulation. 3. If you only use a certain quick and rough cracked line, that is, a certain line will jump once it is supplied with power, it means that there is a leakage of this line. 4. If an electrical appliance does not jump at the beginning when it is used, but jumps after a while, it means that the insulation of the electrical appliance is aging, and the thermal stability deteriorates and leakage occurs.

  8. Anonymous users2024-01-31

    Summary. The socket is incorrectly wired, which may cause tripping when used.

    If there is a short circuit or leakage fault inside the electrical appliance, it will also trip when plugged into the outlet.

    Leakage of power from the line of the socket branch.

    The socket trips after a while.

    The socket is not wired incorrectly, which may cause tripping when the first plug is used. If there is a short circuit or leakage fault inside the electrical appliance, the line of the socket branch will also be tripped when the socket is plugged in.

    Sometimes it takes a long time, sometimes it takes a short time, and then there is a trip. It has little to do with the power of electricity.

    Sometimes it takes a long time, sometimes it takes a short time, and then there is a trip. It has little to do with the power of electricity.

    Kiss you, take a look at the leakage protector, maybe this thing is broken.

    The electrical equipment is good, and wiring errors are almost eliminated.

    The electrical equipment is good, and wiring errors are almost eliminated.

    Is there a mistake between the neutral wire and the live wire?

    Generally, there is a problem with high electrical power.

  9. Anonymous users2024-01-30

    Summary. Hello, under the premise of correct wiring of the socket, the reasons for tripping as soon as electricity are used: 1. The live wire and the neutral wire of the socket are reversed, or the contact of the socket is in poor contact.

    Hello, under the premise of correct wiring of the socket, the reasons for the tripping of electricity are: 1. The live wire of the Pibu socket and the zero digging touch wire are reversed, or the socket contact has poor contact.

    2. There is leakage or short circuit in the electrical appliances used.

    3. The power of the load on the socket line exceeds the rated power.

    4. There is a phenomenon of leakage on the branch road.

    When the zero wire and the live wire of the core are reversed, if the upper circuit is a leakage protector at this time, it will be automatically judged to be leakage protection and cause tripping when it is used. At this time, the power supply should be cut off immediately, and then the neutral wire and the live wire should be replaced back to the correct wiring, and if there is a burned line, it should also be replaced in time.

    When there is a short circuit or leakage of the electrical appliances used, if the socket is used at this time, it will cause the leakage protector to break and trip. You should immediately cut off the power supply and check the electrical appliances, and you can contact the maintenance master in time.

    The situation that the load of the line is more than the rated power is because several electrical appliances used by Sun Kong are high-power electrical appliances, and when used together, the rated power of the circuit will be exceeded, resulting in air tripping. It is advisable to minimize the number of thoughts used when using electrical appliances.

    The leakage of the branch road is because the leakage current of Husen eggplant does not reach 30 milliamperes at this time, so the leakage protector will not trip, but after plugging in the electrical appliances, the current becomes larger and immediately jumps to check the brake.

  10. Anonymous users2024-01-29

    Summary. The first step is to check the switch in the distribution box or the leakage protector 1, look at the situation in the subject's home every time the main switch trips, the main gate is a leakage protector, the opening situation is not known, either the leakage protector or the leakage protection; 2. We first check the main switch, the easiest way is to replace a new total leakage warranty to see if it is still tripped; 3. If it still trips after replacement, then the problem of the switch is eliminated. The second step is to check the household appliances in our home 1, this step of the inspection is more troublesome, we have to check the household appliances in our home one by one, in order to eliminate which electrical appliances have problems; 2. The biggest problem with the electrical appliances at home is the desktop computer, we unplug all the sockets of the desktop computer, and observe for a period of time to see if it still trips; 3. Then other household appliances are observed one by one according to this method, so that we can confirm whether it is the tripping caused by the leakage of household appliances.

    The third step is to check that there is a problem with the wiring at home 1. After checking the switch and electrical appliances, if you still can't find the problem, it is basically a problem with the wiring; We have to check the line, because every time we trip the main switch, the most likely problem is that there is leakage in the line, and the leakage current of each circuit is less than 30 milliamperes, and the leakage current of multiple circuits will definitely exceed the tripping current of the total leakage protector, so it will trip the main switch;

    The power switch that controls the socket trips shortly after it is closed, and all electrical appliances are unplugged.

    The first step is to check the switch in the distribution box or the leakage protector 1, look at the situation in the subject's home every time the main switch trips, the main gate is a leakage protector, the opening situation is not known, either the leakage protector or the leakage protection; 2. We first check the main switch, the easiest way is to replace a new total leakage warranty to see if it is still tripped; 3. If it still trips after replacement, then the problem of the switch is eliminated. The second step is to check the household appliances in our home 1, this early crack step inspection is more troublesome, we have to check the household appliances in our home one by one, in order to rule out which electrical appliances have problems; 2. The biggest problem with the electrical appliances at our home is the desktop computer, we unplug all the plug-in and closed seats of the desktop computer, and observe for a period of time to see if it still trips; 3. Then other household appliances are observed one by one according to this method, so that we can confirm whether it is the tripping caused by the leakage of household appliances. The third step is to check that there is a problem with the wiring at home 1. After checking the switch and electrical appliances, if you still can't find the problem, it is basically a problem with the wiring; We have to check the line, because every time we trip the main switch, the most likely problem is that there is leakage in the line, and the leakage current of each circuit is less than 30 milliamperes, and the leakage current of multiple circuits will definitely exceed the tripping current of the total leakage protector, so it will trip the main switch;

    There are too many overload trips in the electrical appliances at home, and the electrical appliances will trip if they have a short circuit, and they will trip when they are pushed, and there is a leakage sensitive branch tripping, if all the electrical appliances are turned off or tripped, it proves that the subordinate circuit has leakage, and it is necessary to find a professional electrician to repair.

Related questions
7 answers2024-04-11

There are many types of ground sockets, among which the size of the pop-up ground socket: 120*120mm, the size of the open ground socket: 146*146*4mm, and the size of the spiral ground socket: 130mm*130. >>>More

10 answers2024-04-11

The principle of lightning protection socket is to use a transient voltage absorber such as a lightning arrester or varistor and between the input lines, which usually behaves as an infinite impedance; When the transient voltage occurs, the impedance of the device decreases rapidly, and the transient energy is transferred to protect the internal electrical equipment. >>>More

7 answers2024-04-11

Introduction: In recent years, we can often see news reports on TV which factory had a fire or **occurred at night, and caused serious ** and property damage, and finally learned after investigation that it was due to aging lines or leakage. It's a shame that sometimes people just go for a little bit of cheapness, and it ends up with a sad accident. >>>More

7 answers2024-04-11

There are many places where sockets will be installed, and now is the era of electrification, so sockets are more common, because every electrical appliance is installed with sockets, but there are also different types of sockets, so we should pay attention to it when installing, so how to wire the switch with sockets? What are the key points of switch with socket wiring? Next, let's introduce it to you by the decoration home network. >>>More

6 answers2024-04-11

1. Switch control socket. Firewire connector L1, switch L and socket L are connected with **, the neutral wire is connected to socket N, and the ground wire is connected to socket E (grounding symbol). >>>More