If the drawings do not indicate that it can be set according to the requirements of the specification, the general wall length is more than 4m and structural columns must be added.
-
1. When the length of the straight section separated by no concrete wall (column): 120 (or 100) thick wall exceeds, and 180 (or 190) thick wall exceeds 5m, concrete structural columns are added in the interval.
Separate. (or 100) thick wall: when the wall height is less than or equal to 3 meters, the width of the opening is less than or equal to, if it is not satisfied, structural columns or reinforced concrete should be added.
Horizontal tie beams. (or 190) thick wall: when the wall height is less than or equal to 4m, the width of the opening is less than or equal to, if it is not satisfied, a structural column or reinforced concrete horizontal tie beam should be added. There are no frame columns at the corners of the wall.
At the junction of walls of different thicknesses, structural columns should be arranged.
4. When the wall length is more than 5m (or the wall length is more than 2 times the height of the storey), the structural column should be set in the middle of the wall length (at the edge of the hole in case of a hole).
Precautions for Structural Column Settings:
Structural columns should be associated with ring beams.
Connections, longitudinal reinforcements of structural columns.
The ring beam should be passed through to ensure that the longitudinal reinforcement of the structural column runs through up and down, only in this way can the overall rigidity be really increased, and the role of the structural column and the ring beam can be played, and it should be known that the structural column is generally designed at the four corners of the room, the four corners of the staircase, and the corners of the house.
In addition, the design number of structural columns, generally according to the height of the house, the pressure at the bottom or whether the local conditions belong to the multi-town area, etc., once to ensure the quality of the house, at the same time, it should be noted that if the structural column is set at the four corners of the outer wall, it is necessary to stretch a bay on the outer wall, and in other cases, the outer longitudinal wall and the corresponding transverse wall should be pulled through, and the height of the cross-section should be greater than or equal to four skin bricks.
-
There are normative requirements, as follows:
First, the setting of the structural column.
The regulations on the location of structural columns require that regardless of the number of floors and the intensity of the house, structural columns should be set at the four corners of the exterior wall, at the junction of the transverse wall and the external longitudinal wall at the staggered part, on both sides of the larger opening, and at the junction of the inner and outer walls of the large room.
Second, the structure of the structural column.
1.The structural column should be connected with the ring beam, and the longitudinal reinforcement of the structural column should pass through the ring beam to ensure that the longitudinal reinforcement of the structural column is connected up and down. For houses with ring beams on the compartment, reinforced brick belts should be set on the floors without ring beams.
Only when the structural columns are set at the four corners of the outer wall, a bay should be stretched out on the outer wall, and in other cases, the outer longitudinal wall and the corresponding transverse wall should be pulled through, and the cross-sectional height should not be less than the four-skin brick, and the mortar strength should not be lower than M5 grade.
2.The junction between the structural column and the wall should be built into a horsetooth, and should be along the wall height every 500 mm, set 2 6 Rachel reinforcement, each side extends into the wall not less than 1 meter or extends to the edge of the hole.
3.The minimum cross-section of the structural column can be 240 180 mm, the structural column of the four corners of the house can appropriately increase the cross-sectional size, the construction should be built first and then poured column, the concrete strength grade of the structural column should not be lower than C15, the steel bar grade is generally grade 1 steel, the thickness of the concrete protective layer is 20mm, and shall not be less than 15mm, and should not be greater than 25mm. The longitudinal reinforcement should be 4 12, the stirrup spacing should not be greater than 250mm, and the upper and lower ends of the column should be properly encrypted; More than 6 layers at 7 degrees, more than 5 layers at 8 degrees, 4 14 should be used for the longitudinal reinforcement of the structural column at 9 degrees, and the stirrup spacing should not be greater than 200mm.
At the junction of the ring beam and the structural column, the ring beam reinforcement should be placed on the inner side of the structural column reinforcement, that is, the structural column is regarded as the support of the ring beam, which is beneficial to the structure.
4.The structural column can not be set up separately, but should extend into the ground 500mm, it is advisable to set up a concrete seat with a thickness of 120mm at the root of the column, and the vertical reinforcement of the column is anchored in the seat, which is conducive to earthquake resistance and convenient construction. When there is a foundation ring beam, the vertical reinforcement of the structural column can be anchored in the foundation ring beam 50mm below the outdoor ground.
If the foundation ring beam is higher than the outdoor ground (the height difference between indoor and outdoor is large), the structural column should still be extended 500mm below the outdoor ground, and a concrete seat with a thickness of 120mm should be set at the root of the column. When the wall is attached to the pipe trench, the depth of the structural column should be greater than the depth of the trench.
3. Reinforcement of structural columns.
1.The longitudinal reinforcement of the structural column should not be less than 4 12, and the side column and corner column should not be less than 4 14. When seven degrees are more than 6 layers, when 8 degrees are more than 5 layers, and when 9 degrees are longitudinal reinforcement should be used 4 14.
The diameter of the vertical stressed steel bar of the structural column should not be less than 16mm. The vertical stressed reinforcement of the structural column should be anchored in the foundation beam and the floor ring beam, and should meet the anchorage requirements of the tensile reinforcement.
2.The minimum diameter of the stirrups of the structural column is 6, the spacing should not be greater than 250mm, and the stirrup spacing is encrypted to 100mm within the range of the upper and lower ends of the column greater than or equal to H 6 (h is the layer height) and greater than or equal to 450mm.
-
The requirements for the setting of structural columns are divided into the following situations: involving masonry structures, frame infill walls and seismic design.
Code for design of masonry structures (GB50003-2011).
10 2 4 cast-in-place reinforced concrete structural columns (hereinafter referred to as structural columns) of various types of brick masonry houses shall be set up in accordance with the relevant provisions of the current national standard "Code for Seismic Design of Buildings" GB 50011 before the fiber, and shall comply with the following provisions:
1. The setting position of the structural column should be in accordance with Table 10provisions;
2 For verandah-type and single-sided verandah-type houses, the number of floors should be increased according to the number of floors of the house, according to Table 102 4 requires Luqing to set up structural columns, and the longitudinal walls on both sides of the single-sided corridor should be treated as external walls;
3 For houses with fewer transverse walls, structural columns should be set according to the number of floors added to the house according to the requirements of Table 10 2 4. When the house with fewer transverse walls is of the verandah type or the single-sided corridor type, the structural column shall be set in accordance with the requirements of paragraph 2 of this article; However, when 6 degrees does not exceed 4 layers, 7 degrees does not exceed 3 floors and 8 degrees does not exceed 2 floors, it should be treated as the number of layers with two layers;
4. For houses with few horizontal walls on each floor, structural columns should be set according to the number of floors with two additional floors;
5 the use of autoclaved lime sand ordinary bricks and autoclaved fly ash ordinary bricks of vertical masonry house, when the shear strength of masonry only reaches 70 of ordinary clay brick masonry (ordinary mortar masonry), should be according to the number of layers of the additional layer according to the requirements of paragraph 1 4 of this article to set up structural columns; However, when 6 degrees does not exceed 4 layers, 7 degrees does not exceed 3 floors and 8 degrees does not exceed 2 floors, it should be treated as the number of layers with two layers;
6. For multi-storey houses with staggered floors, walls should be set up at the split-level parts, and structural columns should be set at the junctions of them and other walls; Cast-in-situ reinforced concrete ring beams should be arranged at the location of the split-story floor slab at the split-layer part; When the number of floors of the house is not less than four floors, the spacing of the structural columns in the middle of the staggered part of the bottom 1 and 4 floors should not be greater than 2m.
-
When the wall is longer than 5 meters, the top of the wall and the beam (plate) should have the old steel bar to pull the joint, when the top of the tie construction is difficult, the structural column can be set in the masonry filling wall, and the spacing is 5 meters); When the wall is longer than 2 times the height of the storey, it is advisable to set up structural columns; When the wall height exceeds 4 meters, a concrete cast-in-place belt should be set up with a half-height or door opening upper skin that is connected with the column and runs along the wall.
1. When the wall is longer than 5m, or more than twice the height of the floor.
2. At the corner of the wall.
3. Masonry T-shaped junction.
4. The size of the door and window openings is greater than or equal to meters, and the structural column needs to be set up if it is less than one meter. )。
5. Structural columns should be set up on the parapet wall.
1. The ring beam should be continuously arranged on the horizontal plane and form a closed shape.
2. The thickness of the ring beam wall should be the same as the thickness of the wall; When the wall thickness is not less than 240mm, its width should not be less than two-thirds of the wall thickness, and the height of the ring beam should not be less than 120mm.
3. 4 steel bars of not less than 10mm should be set in the longitudinal direction.
4. The stirrup spacing should not be greater than 300mm.
-
Structural columns. The setting requirements are: multi-storey houses of verandah type and single-sided corridor type should be added according to the number of floors of the house, and then the structural columns should be set according to the requirements of the following table, and the longitudinal walls on both sides of the single-sided corridor should be treated as exterior walls.
For houses with fewer horizontal walls, the number of floors should be increased according to the number of floors of the house, and then the structural columns should be set according to the requirements of the following table. When the house with fewer transverse walls is an outer corridor type or a single-sided corridor type, structural columns should be set up according to the requirements of paragraph 2 of Article 2 at the same time; However, when 6 degrees does not exceed 4 layers, 7 degrees does not exceed 3 floors and 8 degrees does not exceed 2 floors, it should be treated as the number of layers with two layers;
For houses with few horizontal walls on each floor, structural columns should be set according to the number of floors with two additional floors. Autoclaved sand-lime bricks are used.
masonry house, when the shear strength of masonry.
When only 70% of the ordinary clay brick masonry is reached, the structural column should be set according to the number of layers of the additional layer according to the requirements of paragraphs 1-4; However, when 6 degrees does not exceed 4 layers, 7 degrees does not exceed 3 floors and 8 degrees does not exceed 2 floors, it should be treated as the number of layers with two layers;
-
As follows
1. The bottom or middle floor fills the wall virtually, and the structural column is set at the middle branch where the wall is more than 5 meters long or 2 times the height of the storey, and the column spacing should be less than 5 meters after the middle division.
2. For the roof parapet wall, a structural column is set at the middle division where the wall length exceeds one meter, and the column spacing after the middle division should not be less than one meter.
Infill walls belong to masonry, and the Code for Design of Masonry Structures and Code for Seismic Design of Buildings have relevant regulations on infill walls.
Expand the information and talk about it.
The setting of structural columns in the building should be in accordance with the following requirements:
1. According to the requirements of seismic codes, the structural columns are mainly arranged in the seismic walls.
2, 120 (or 100) thick wall when the wall height is less than or equal to 3 m, the width of the opening is less than or equal to, if not satisfied, the structural column or reinforced concrete horizontal tie beam should be added.
(or 190) thick wall when the wall height is less than or equal to 4m, the width of the opening is less than or equal to, if not satisfied, the structural column or reinforced concrete horizontal tie beam should be added.
4. When there is no frame column at the corner of the wall and at the junction of the wall of different thicknesses, structural columns should be set.
5. When the wall length is more than 5m (or the wall length is more than 2 times the height of the storey), the structural column should be set in the middle of the wall length (at the edge of the hole when there is a hole).
6. Structural columns should be set on both sides of the larger openings and at the ends of the unconstrained walls, and the structural columns and the wall tie bars should be 2 6@500, and arranged along the full height of the wall.
-
What are the requirements for the setup of structural columns? Cast-in-place concrete structural columns should be set at the specified parts of the wall according to the masonry structure system, masonry type, force or stability requirements of the structure or components, and other functional or structural requirements; For masonry structure houses with large bay loads or high floor heights, base hills, and floors greater than or equal to 8 floors, structural columns should be set according to the following requirements: (1) both ends of the wall; (2) both sides of the larger opening; (3) The junction of the vertical and horizontal walls of the house; (4) The spacing of the structural columns, when considering the force of the structural column according to the composite wall, or considering the structural column to improve the stability of the wall, its spacing should not be greater than 4m, and in other cases, it should not be greater than 1, 5-2 times and 6 times of the wall height
5) The structural column should have a reliable connection with the ring beam.
-
Kiss, <>
We are glad to answer the requirements for the setting of structural columns: when the length of the straight section without concrete wall (column) separation, when the thickness of 120 (or 100) thick walls exceeds 5m, and the thickness of 180 (or 190) walls exceeds 5m, concrete structural columns are added to separate the section; 120 (or 100) thick wall, when the wall height is less than or equal to 3 meters, the width of the opening is less than or equal to, if it is not satisfied, the structural column or reinforced concrete horizontal tie beam should be added; 180 (or 190) thick wall, when the wall height is less than or equal to 4m, the width of the opening is less than or equal to, if it is not satisfied, structural columns or reinforced concrete horizontal tie beams should be added; In order to enhance the integrity and stability of the building, the reinforced concrete concrete structural column should also be set in the wall of the multi-storey brick-concrete structure building, and be connected with the ring beams of each layer to form a space frame that can resist bending and shearing, which is an effective measure to prevent the collapse of the house. Answer: The structural columns are set at the four corners of the exterior wall, the junction of the horizontal wall and the outer longitudinal wall at the staggered part, on both sides of the larger opening, and at the junction of the external wall of the large room.
In addition, the number of floors and the intensity of the house are different, and the requirements for the setting of structural columns are also inconsistent. The minimum cross-sectional size of the structural column is 240mm 180mm, and the vertical reinforcement is mostly used 4 12 stirrup spacing is not more than 250 mm. Hope mine can help you!
The setup of the construction column.
1. When there is no frame column at the corner of the wall, and at the junction of the wall of different thicknesses, structural columns should be arranged. >>>More
Most of the pilasters are also set in brick concrete, also called brick stacks, and the structural columns set in the wall can also be called pilasters in general, in fact, pilasters can also be stressed alone! In this case, depending on how you calculate, if you calculate it in it, it is a stressed member! >>>More
1.Structural columns and structural columns are used for the conversion layer, the lower part is a frame structure, the upper part is a shear wall structure, and the beams and columns supporting the superstructure are KZZ and KZL. >>>More
How to use the short mugwort.
After Jin Taizu occupied the Yanyun region in the seventh year of Yan Min Tianfu (1123), he set up a privy council to oversee the military affairs of the Han land. When Taizong Tianhui invaded the Song Dynasty in the third year (1125), he set up the Marshal's Mansion to govern the military and government. King Hailing changed the capital of the Marshal's Mansion to the Privy Council, and used the Privy Envoy to take charge of confidential matters. >>>More