-
The base of the waterproof box is one, and it can't be pried open at all, and it will be broken if it is pryed... The correct method is: there is a gap at the bottom of the waterproof box, the panel of the socket switch can be directly pried open from the gap (the bottom is not from the middle position of the left and right sides of the socket switch, and the gap connected with the waterproof box), pry down the panel of the socket switch first, only to see the screw nail that fixes the socket switch, it is to fix the socket switch and the waterproof box together, so it is extremely wrong to pry the waterproof box.
Pry the panel open, remove the screw, the socket switch and the waterproof take are all removed... Note that the waterproof box may be glued to the wall, so you don't need to worry about the waterproof box, just remove the socket switch.
-
The split socket with the anti-stream water box is easy to remove.
Most of the socket removal ports are underneath and there are also ones on the side.
Hydropower must be turned off before ruthlessly dismantling, you need to use a smaller slotted screwdriver or electric pen to open the socket decoration panel, there will be two recessed disassembly points on both sides of the socket with screws to open the panel with two points here, the panel will open the fixed screws on the left and right sides, remove the two screws with a Phillips screwdriver, the socket can be pulled out at this time, and the three wires of the socket can be loosened one by one with a Phillips screwdriver in the state of power failure. Immediately after that, the waterproof box can be easily removed by cutting the adhesive with a wallpaper knife, if it is replaced with a new waterproof socket, the order of installation and disassembly is just the opposite. There should also be an integrated anti-gradual box socket, which is easier to disassemble than this split type, as long as the decorative caps of the screw holes on both sides are removed, you can loosen the screws and disassemble the socket.
-
The toilet socket is mainly to prevent water droplets from splashing directly, and the need to prevent moisture is not great. Here's how I deal with it at home: cut an 85 mm square soft, thick (about 3 mm) plastic soft sheet, the upper edge of the board is fixed on the top of the socket (glue, nail can be), lift the plastic plate and plug in the plug when using the socket, the plastic plate will naturally hang down and cover the socket.
The color of the plastic plate can be made of transparent, similar to the soft curtain hanging in a store, and the plastic plate should be glued between the plastic plate and the wall to prevent water from penetrating into the socket through the gap.
-
1. Turn off the power first.
2. Then use a screwdriver to gently pry open the panel of the socket base and remove the screws.
3. Buckle the mounting bracket and connect the wires.
4. Tighten the screws to fix the mounting bracket on the socket cassette, and buckle the panel and cover. It is recommended to be installed by an electrician to avoid improper operation damaging the waterproof box or improper wiring connection affecting the use.
-
Remove the socket first, then put the waterproof cover behind the socket and then turn the power cord over and press the power cord. Waterproof bathroom power socket Installing a waterproof junction box on the toilet socket will solve the problem.
-
2. How to install the waterproof cover of the bathroom socket Put the waterproof cover on the cassette first, and then put the panel mounting frame into the waterproof cover, screw the installation screws, and cover the cover. The above we recommend for you is about the selection and use of the socket waterproof cover installed in the bathroom, from which you can know that the socket in the bathroom is waterproof...
-
Hello dear! We'll be happy to answer for you. How to remove the waterproof cover of the socket Wu shouting?
Answer, pro: If you want to remove the protective cover of the waterproof socket, you can prepare a small taper and pry it along its small gap. At the same time, observe whether there is a small gap next to the socket panel, and gently pry it open along this small circle with a screwdriver.
If it is fixed with screws, it is even simpler, and the panel can be removed by simply loosening the screws. Therefore, it is not difficult to remove the protective cover, remove the protective cover, if you want to disassemble the wire inside, you need to be able to loosen the wire in the case of power failure, and pay attention to the safety of wire removal and wiring. If you have any missing questions, you can give me feedback in time!
-
To install the waterproof cover of the toilet socket, first disassemble the socket, and put the outer ring of the waterproof cover on the socket, and the specific operation steps are as follows
1. Disassemble the socket first.
2. Put the outer ring of the waterproof cover on the socket.
3. Put the waterproof cover on the socket as a whole. As shown below:
4. Tighten the fixing screw on the right side of the socket.
5. Tighten the fixing screw on the left side of the socket.
6. Cover the cover plate on the edge of the socket.
7. The installation is complete.
-
Put the waterproof cover on the cassette first, then put the panel mounting bracket into the waterproof cover, screw the mounting screws, and cover the cover.
That is, the waterproof cover is placed between the pupil box and the mounting frame.
-
Maybe you don't care about the location of the toilet socket and whether the installation is safe, but you have to think that the water is conductive, and the installation of the bathroom waterproof socket is directly related to the personal safety of the whole family. So, today, let's talk about what are the precautions for the installation of waterproof sockets in the bathroom?
1. When the socket is installed, the distance between the exposed socket and the ground should not be less than one meter; The concealed socket is not less than one meter from the ground, and in order to prevent children from being electrocuted, touched with fingers or poked into the eyelets of the power supply with metal objects, a safety socket with a safety flap must be selected.
2. The construction wiring requirements of the single-phase two-eye socket are: when the eyelets are arranged horizontally, it is "left zero and right fire", and when it is arranged vertically, it is "upper fire and lower zero"; The wiring requirements of the single-phase three-eye socket are: the grounding eyelet at the top must be firmly connected, solid, and right with the grounding wire, and must not be unconnected.
3. The remaining two holes of Suiyan are wired according to the rules of "left zero and right fire", and it is worth noting that the zero line and the protective grounding wire must not be misconnected or connected as a whole; Refrigerators should use a separate, three-prong socket with a protective ground.
4. It is strictly forbidden to connect the grounding wire to the gas pipeline to avoid serious fire accidents; In order to ensure the absolute safety of the family, the socket of the range hood should also use a three-eye socket, and the protection of the grounding hole must not be taken lightly; The toilet is often used to take a bath and take a shower, which is easy to get humid and should not be installed with ordinary sockets.
Fifth, when assembling the switch, the concealed switch guesses that the Hengyu requires meters from the ground and a horizontal distance of 150 mm-200 mm from the door frame. The position of the switch should correspond to the lamp position, and the switch height in the same room should be the same. Waterproof switches should be used in the bathroom to ensure personal safety.
Staying in the bathroom, safety always comes first, everyone must pay more attention to precautions!
-
1. Turn on the wall switch and circuit breaker to be removed. The circuit breaker can control the entire room, or just on a specific wall.
2. Use a flathead screwdriver to fix the switch cover on the wall with the junction box and remove the screws. Remove the cover and the circuit tester's probes are placed on each switch with screw terminals to ensure that there is no force to go to the switch. Indication of the reference circuit tester.
3. Switch, junction box with Phillips head screwdriver unscrew down two screws and wire drawing switch, from the junction box, so that you can access the wire terminal screws on the side of the chain to destroy the surface of the switch.
4. For the switch on the upper side, a Phillips screwdriver loosens the terminal screw and pulls the wire away from the switch. Unplug the switch off the wall.
5. Plastic wire caps at each wire end. Electrical tape wraps around each cap and wire further secures the wire tail cap. The east-west line enters the junction box. A solid cover plate is placed in the junction box and set screws are used for molding. Turn on the circuit breaker that powers the power supply from the outlet.
Bathroom leakage generally does not involve the wall, if you knock on the wall, you only need to pay attention to whether it is a load-bearing wall. However, the waterproofing of the ground should be expanded. The location of the bathroom after expansion must be waterproof!
The first step, before the waterproof treatment of the bathroom, the first thing is to level the floor level of the bathroom, the ground is uneven, when the waterproof paint is painted, it may be uneven, or the ground is easy to crack because of unevenness, which will crack with the ground even if the waterproof paint is applied. >>>More
There is more moisture in the bathroom, so it is necessary to pay attention to the waterproof treatment during the decoration process, and the waterproof must be in place to avoid the problem of water leakage, and the later maintenance is more troublesome. Secondly, the choice of waterproof coating for the bathroom is also very important, what materials are used for waterproofing in the bathroom? It can be mainly divided into the following types: >>>More
Directly on the waterproof paint. And I personally recommend that in the shower room, a position with a lot of water, don't brush to a meter as required, and brush it directly to the top. Stay on the safe side.
To do waterproofing, you need to do it on the surface of the water, and you can do it yourself. >>>More