-
The bathroom has been tiled, but it is still seeping, and it can only be said that the waterproofing of the bathroom is not qualified. We must do an experiment after doing the waterproofing, and wait for 48 hours to check again, otherwise the probability of water seepage and leakage in the later stage will be very high. Moreover, some people's bathroom walls are not waterproofed directly, which leads to the water slowly seeping out, which affects the bathroom.
Teacher in the decoration must choose the acceptance to know what the winning lottery is, don't let others say well, we don't look at the direct signing, once the sign after the problem, then you can only solve it yourself, some people say that my bathroom has been pasted with tiles, but it is still seepage, can only say that your waterproof is not qualified. There is a high probability of this kind of problem if there is no test at the beginning, if the test was found to be unqualified, we can still modify it in time, but now you have finished pasting the tiles, and then want to do waterproofing, it is estimated that it is a little late<>
It may also be because the wall of the bathroom is not waterproofed, and we will have water splashed for 4 weeks when we take a bath or wash our face, which will slowly lead to water on the wall, and if it is waterproof, its water will slowly fall, and if it is not waterproofed, it will seep into the wall, thus affecting the bathroom. Therefore, when we do waterproofing, we must do it in every room, so as to avoid water seepage. <>
You should also consider that the root of the pipe in your bathroom is not waterproofed, and you must know that waterproofing is not done on the wall, but also on the root of the pipe. Floor drains, toilet sewers these locations must ensure effective waterproofing, if your home does this, the upstairs seeps down, it can only be said that the upstairs is not in place, so we can go to the upstairs for them to repair or control. Be sure to seal it well, otherwise when using water, the water will also penetrate below and flow down the pipe wall to the downstairs, and we need to spend more money at that time.
-
If the bathroom has been tiled, but still has been seeping, I think this situation may be in the bathroom is not waterproofed when the leakage occurs, it is recommended that it is best to renovate the bathroom in time.
-
This is a problem with the sewer in the bathroom, and the bathroom should be renovated to solve this problem.
-
It is possible that there is a leak in the pipes, or there may be a leak in the waterproof layer.
-
Because your pipes are hidden, and the water in and out is suspicious, it is very troublesome to investigate. The leak is now under the washbasin, so the focus is on the triangular valve of the washbasin and the drain pipe that goes from the floor to the wall. Close the triangle valve first, check whether the water meter is moving, check whether the water inlet pipe is leaking, and test the pressure if necessary; If the water supply pipe is well sealed, it means that there is a leak in the wall outlet pipe, and it is best to find an experienced plumber to go to the site to investigate this problem for you.
-
Are there any holes in the ground? Did you break the water pipe under the bricks?
-
Bathroom tile paste bai, tile joints and water seepage, you can use waterproof dao fine joint agent to do waterproof treatment, the specific operation steps are as follows: capacity.
1. Use a wallpaper knife to clean the gaps in the tiles.
2. Put water into the balloon and prepare to use the balloon to plug the floor drain.
3. Use balloons to plug the floor drain.
4. Prepare 20 catties of tap water.
5. Pour waterproof fine seam agent into the bucket.
6. Stir well.
7. Fall on the floor of the bathroom.
8. Use a broom to sweep the adjusted waterproof fine seam agent to every corner of the bathroom.
9. After waiting for an hour, use a shovel to scoop up the solidified waterproof seam agent.
10. Clean up the solidified waterproof seam agent.
11. The waterproof fine joint agent penetrates into the gap of the tile and solidifies after mixing with the sediment, which will play the role of waterproofing, and the operation is completed.
-
Sanitary bai
Water seepage treatment method for tile joints: du
1. Cause analysis
The first thing to do is to understand what causes water seepage in the bathroom tile, and there are several reasons: first, the waterproofing of the bathroom is not in place; The second is that the water pipe in the wall is broken and leaks; There is also in the rainy weather, due to the humid air, resulting in water on the surface of the tile; Finally, the tile gaps are not good, and there is water seepage.
2. Solution:
If there is a problem with the waterproof layer, the tiles must be removed, the wall must be beaten to the waterproof layer, and it is better to see the inner wall, and then scrape the putty again, re-make the waterproof layer for the wall, and then pave the tiles, which is generally more complicated.
The second is that the water pipe rupture leads to water seepage, in this case, the water pipe needs to be tested to see if there is a water leakage, if it is indeed caused by the water pipe damage, to find out the leakage immediately, open the wall and replace the water pipe.
If the wall is only leaking because of moisture, you only need to pay more attention to the ventilation and cleaning of the bathroom in your daily life.
If the tile gap is not good, there is water seepage. First of all, you need to use cement or caulk to fill the cracks, and then make a layer of waterproofing.
Hope it helps!
-
The direct use of sewing agent does not cause mildew and bacteria, and it can also be DIY
-
The bathroom has been tiled, but it still seeps water, what should I do?
If you find a leak after the tile is pasted in the bathroom, try to analyze the leakage before you can do the same treatment. The first reason may be the rupture and leakage of the water pipe, such a thing at the beginning of everyone to find the point of leakage in **, generally speaking, if it is water seepage, the water flow will be relatively large, and it will last for a long time. If there is a leak in the sewer pipe in an area such as a washbasin or toilet, you can directly pour some water into it to detect it.
If there is a leak in the water pipe, then everyone will stop using the bathroom for a few days, and the leakage will be found, then it is a problem for the water inlet pipe. After confirming the leakage point, there are two types of treatment methods, immediately destroying the surface layer of the floor tiles, and digging out the water pipe again to repair and disassemble, this kind of method is very inconvenient. The second way is to immediately apply the method of walking and walking and walking the open pipe, which is likely to be not very good on the surface of the pipe.
It may be a problem caused by floor drain odor prevention, which is a more commonly used water seepage problem, and there are many factors that cause this situation. Here, one of them is that if a fully automatic washing machine is placed in the bathroom, then many owners generally make a floor drain deodorization of the washing machine sewer pipe, that is, the washing machine sewer pipe is immediately connected with the floor drain deodorization.
If the drainage pipe of the washing machine is very large and the floor drain is not very large, the efficiency of the washing machine sewer pipe is higher than that of the floor drain and anti-odor drainage pipe, which will cause the situation of backwater, that is, the water discharged by the automatic washing machine flows home. For this situation, there are two solutions, the first is to replace the floor drain, but this method may not be applicable, considering that there are many specifications and models of floor drain anti-odor drainage pipes in residential buildings. The second is to disassemble the drain pipe of the washing machine and replace it with a smaller sewage pipe.
-
1.Treat the dust, oil, and stagnant water on the surface, and keep the surface dry;
2.If the tile joint is filled with caulk, a small groove needs to be cut with a knife;
3.In the ceramic tile surface, tile joints, wall joints, pipe roots and other cement parts, spray penetrating waterproofing agent, be sure to spray evenly;
4.After the waterproofing agent 9 is dry (about 2 hours later), fill all tile joints and damaged and defective parts with caulk paste, and the weak links such as around the pipe root are reinforced;
-
Then it means that the waterproofing of the bathroom is not done well, and the tiles need to be removed and remade, so that you can live better.
-
It needs to be renovated to determine the specific leakage, otherwise it is likely to affect the other rooms.
-
The causes and solutions of water seepage in the tile joints above the bathroom are as follows:
1. If it is caused by the leakage of the toilet water pipe, you can use tools such as a leak meter to determine the leakage point of the water pipe. When repairing leaking water pipes, we can turn off the toilet inlet valve, use a hammer and other tools to knock off the tiles at the leakage point, cut off the leakage of the pipe, and connect the new water pipe with a hot melt connection. After the pipes are repaired, the tiles are re-installed.
2. If the bathroom waterproofing is not done well, you can use brick-free waterproof products to repair it. You can clean up the bathroom tile joints, seal the bathroom floor drain, stir the brick-free waterproof products according to the requirements, and then pour them on the tiles, use brooms and other tools to spread the waterproof products evenly, after about 1 hour, clean the ground, and then re-do the tile seams.
3. If the bathroom waterproofing is not done well, you can also do it again. Although this method of patching is more costly, it will be more effective. We should warp off the floor tiles, re-do the waterproofing as required, and we should pay special attention to the waterproofing treatment at the junction of the pipes when doing waterproofing.
After the waterproof acceptance is qualified, we will pave the floor tiles well.
Bathroom waterproofing precautions
1. The waterproof height of the bathroom.
When waterproofing the bathroom, we should pay attention to the waterproof height, the general waterproof height should be more than 30cm, if it is a non-load-bearing wall, the waterproof should be 60cm high.
2. Waterproof coating of the bathroom.
Pay attention to the gap between the bathroom wall and the ground, and apply the waterproof coating in place to avoid water leakage.
3. Waterproof paving of toilets.
If the bricks are re-paved, the original floor tiles can be replaced, the original floor tiles can be chiseled off, and then leveled with cement mortar, and then waterproofed.
4. The bathroom is bent into the waterproof wall groove.
For the inner water pipe groove of the bathroom, it is also necessary to pay attention to waterproofing, especially around the hole.
First of all, the water leakage is due to the fact that the waterproofing is not done well, and it has nothing to do with the tile. >>>More
Bathroom tile seepage This is a common problem in many homes, because of various reasons lead to wall tile water seepage, in addition to affecting the appearance of the bathroom, more affects the use of the bathroom, over time these seepage places may have the danger of tiles falling off. >>>More
The floor tiles and wall tiles of the bathroom have been tangled for a month, and the merchants who sold bricks have been tossed several times in the middle, either the size is not right or out of stock, and the deposit is returned, and they are tired, which god gives some advice, small apartment, no design company and no designer to draw, all rely on their own imagination, refer to a lot of Sumitomo's drawings, or can't settle down, to blow up wow, the first self-installed house, I'm afraid that the effect I want can't come out.
If the bathroom is not dismantled, the old floor should be polluted, and the main thing is to clean and remove stains. >>>More
If there is water seeping at the bottom of the toilet toilet, check whether it is a leak in the toilet flush, or a leak caused by a blockage under the toilet, or the toilet is permanently loose, or the toilet is not installed properly and there are gaps, or it is caused by uneven floors, etc. >>>More