Intelligent energy-saving technology: energy-saving inverter, smart timing, night heating mode, sleep function;
2.Low-energy saving technology: no need to replace magnesium rods, excess hot water output;
3.Thermal insulation and energy saving: efficient thermal insulation, medium temperature thermal insulation;
4.Heating energy-saving technology: Z8 high-efficiency heating tube 9 patent number (, the original factory has built-in precise temperature control to avoid the loss of the inner tank and heating tube caused by repeated heating;
5.Beiheng Technology: According to different water intelligence, it actively removes the corrosion factors in the water, comprehensively intelligently protects the inner tank and heating tube, and the titanium ion rod has long-lasting protection, no need to replace, and does not produce the chemical reaction caused by the traditional magnesium rod anti-corrosion liner, and the effluent water quality is cleaner;
6.Intelligent security guard: 10 intelligent detection and scanning per second, even if there is a milliampere leakage current, the security guard will cut off the power supply within seconds;
7.Safety warning: In case the ground wire is electrified, the security system will give an alarm prompt and cut off the power supply immediately to ensure safety;
8.Intelligent antibacterial cleaning function;
9.intelligent antifreeze technology;
10.Control mode: unlimited remote control and host control, special child lock.
Detailed parameters: Capacity: 100L
Power: Suitable for the number of people: 3 to 4
Hand control remote control: wireless remote control hand control.
Water temperature range: 40°-80°
Warranty: 1 year.
-
It's hard to read the literal meaning, it's a typo, is it two indicators on?
-
The temperature sensor is out of order and needs to be replaced. The way to check is to remove the sensor rod and turn on the power (pay attention to safety!). After that, use a lighter to burn the tip of the rod and see how the indicator light works.
Or the simple solution is to turn down the water temperature and see if it works; 2.The bulb burns out and needs to be replaced; Measuring the two feet of the bulb directly with a multimeter should be fine. In addition, the temperature control part of some old-fashioned water heaters is divided into two parts, one is the temperature control circuit, and the other is the anti-dry-burning leakage protection device, any one of the two may cause the indicator light to not work.
-
Dear, hello, I'm glad to answer for you, what does it mean that the Ariston water heater shows that the Beiheng tank is 0 Answer: It may be that the inner tank needs to be cleaned, if the inner tank has not been cleaned for a long time, the water heater will prompt the L0 indicator light, at this time, you only need to clean the inner tank according to the official instructions; Or you can also try to lower the temperature to see if the display screen shows the hall code is normal. It is the meaning of which Beiheng inner tank is broken, and it is recommended that Qidan clean the inner tank.
The general phenomenon is that the Beiheng gallbladder is 0, these words flash, and the display screen does not automatically extinguish. You can look at the instructions to see if there are any relative countermeasures, if not, it is recommended that you find someone who understands this area. 1. It may be because there is a circuit failure in the connection to the water heater, because the line is not connected, resulting in the water heater not being energized.
2. It may be because of the leakage of the water heater, and after the leakage protector detects the fault, it makes a trip action, resulting in the water heater not being powered on. 3. It may be that there is a fault in the water heater itself, such as a burning pipe, a damaged computer board, a malfunction of the thermostat, etc.
-
Ariston electric water heater Beiheng gallbladder flickering how to eliminate hello dear, the operation steps are as follows; 1.Pulser failure. Solution:
Disassemble the outlet valve and reinstall the button stem parts. 2.Battery valve failure:
If you only hear the sound of ignition when using the water heater, but do not hear the clicking sound, it is likely that the solenoid valve of the water heater is damaged or aging, resulting in the loss of control of the solenoid valve. This can be done by replacing an aging or damaged solenoid valve. Ariston water heater Beiheng gallbladder has been flashing to eliminate the steps not **3
The main switch of the water control power supply is in poor contact, resulting in the failure of the fan of the strong exhaust water heater. Open the water heater shell to check 4If there is a problem with the water pressure of the water heater, because the water outlet of the faucet is small, or because the water heater inlet pipe is blocked, the water inlet of the water heater will be affected, which in turn will affect the use.
5.The smoke pipe is too long, which is also not conducive to smoke emissions. Workaround:
Clean the blockage in the smoke pipe, if the smoke pipe is too long, you can cut off the excess smoke pipe of the shed. 6.Ignition porcelain needle or induction porcelain needle problem:
There is no ignition sound and no electric sparks. Solution: Check whether the ignition needle is out of position or aging, and replace or place the ignition needle correctly.
If the induction porcelain needle is aging, the induction porcelain needle can be polished and placed as long as the flame can fully burn the porcelain needle. 7.It may be that the battery of the water heater is running low, or the battery has been aging for a long time.
8.Clogged filter screen at the water inlet: It will cause cold water to not enter the water heater normally.
The solution is to clean up the blockage of the filter at the inlet. 9.Solenoid valve failure.
It is a very common fault, usually the solenoid valve failure includes two kinds, damage and aging, such as when ignition, it can be ignited, but it will be extinguished immediately, and if it is damaged, it is not known that the cavity bridge is at all. Solution: Replace the solenoid valve, I hope my answer will be helpful to you, and finally I wish you good health and a happy mood!
-
Hello, it is necessary to clean the inner tank, if the inner tank has not been cleaned for a long time, the water heater will prompt the L0 indicator light, at this time, you only need to clean the inner tank according to the official instructions for cleaning; Or you can also try to lower the temperature to see if the display is normal. Cleaning the inner tank: If you want deep cleaning, you have to use the small hole on the side, and you must first cut off the power and water, at this time you must release all the water, and then remove the cover next to it, and a hole will appear, so that all the parts are removed, and the dirt in the inner tank is cleaned up with tools, and then installed back at one time, so that the inner tank is filled with water and rinsed.
No matter what method is used, it is necessary to cut off the power first, turn off the water valve, let the hot water in the inner tank be cold, and then clean, there is a sewage outlet next to the inner tank, open it and let the sewage flow out of this place, and wait until it is finished, and then clean it with clean water several times. I hope my reply can help you, if you have any follow-up questions, please feel free to ask me, I will reply to your <> as soon as possible
<> Ariston water heater in use, what does it mean to show that the Beiheng clutch is 0.
Hello, it is necessary to clean the inner tank, if the inner tank has not been cleaned for a long time, the water heater will prompt the L0 indicator light, at this time, you only need to clean the inner tank according to the official instructions; Or you can also try to lower the temperature to see if the display is normal. Cleaning the inner tank: If you want deep cleaning, you have to use the small hole on the side, and you must first cut off the power and water, at this time you must release all the water, and then remove the cover next to it, and a hole will appear, so that all the parts are removed, and the dirt in the inner tank is cleaned up with tools, and then installed back at one time, so that the inner tank is filled with water and rinsed.
No matter what method is used, it is necessary to cut off the power first, turn off the water valve, let the hot water in the inner tank be cold, and then clean, there is a sewage outlet next to the inner tank, open it and let the sewage flow out of this place, and wait until it is finished, and then clean it with clean water several times. I hope my reply can help you, if you have any follow-up questions, please feel free to ask me, I will reply to your <> as soon as possible
<> also does not heat. Kiss you and take a look at the method above.
Ariston brand is good, when I was at the scene of Gome tube, I felt that in fact, now the technology is so developed, the quality of the products is not much worse, which accessories ** purchase of the general manufacturers are known, famous brands, the quality of the general will not be too much difference, when it comes to constant temperature, I have a suggestion, because I am an instantaneous water heater, many manufacturers say that he is a water heater is constant temperature,,, normal temperature is a water heater, it is not affected by small flow, that is to say, the water is large, the water is small, As long as you adjust the water temperature of the water heater, it will generally not change, you can, try it this way, adjust the water temperature of the water at 40 degrees, and then turn on the machine, look at the water flow and water flow, and then, artificially put the water into the triangle valve, close the small point, and then look at the reading of the water temperature displayed by the machine, if the reflection is very slow, a few seconds, or the water temperature goes up all of a sudden, and it comes down again after a while, and then it reaches 40 degrees,,, then this water heater is not really constant temperature,,, I finished,
Ariston Electric Water Heater** It's not uncommon for maintenance personnel to weigh out of warranty. >>>More
This one. Forehead. I just know that I don't know about this super run!!
The cylinder pressure reducing valve is damaged or the air pressure is insufficient. Maintenance method: Replace the pressure reducing valve. >>>More
My AO Smith water heater has been used for 5 years, has been leaking, and can not be repaired after sale, and then saw on the Internet that Haier's water heater has a very good reputation, so I bought Haier's water heater, the next day Haier's master installed it, only to find that the old water heater could not be removed because of rusty bolts, at that time I and the master were desperate, and finally the master took out an angle grinder from the toolbox, and it took almost three hours to remove the old machine, and then installed the new water heater, during which the master did not complain, Finally, he also said that the dismantling of the old machine is free of charge, and there is no service fee. Kudos to Master and Haier.