There is no effect at all, the water in the drainage pipe is the water in nature (the cooling principle of air conditioning is to change the moisture in the air from gaseous to liquid heat absorption, and the resulting water is discharged from the drainage pipe), the drainage pipe is easy to breed mosquitoes in summer, and it is better to put it outdoors if possible.
-
If the drain pipe of the air conditioner is used indoors, it will not affect the health of the body, and it is best to pay attention to whether there are impurities deposited in the drain pipe and clean it up in time
-
You're talking about condensate pipes! It doesn't matter if you put it in**! It is important to put it indoors and you have something to catch the water! Due to the hot weather in summer, turning on the air conditioner can produce a lot of condensation! So it will be troublesome to get water indoors!!
-
It doesn't affect. However, the air conditioner drain pipe is placed indoors for drainage. It will lead to an increase in indoor humidity, and it is easy to run water if you are not careful.
-
No health effects. The water discharged from the air conditioner refrigeration is formed by the condensation of the moisture vapor in the air on the air conditioner evaporator, and does not contain harmful substances. After collecting, it can be used to flush the toilet and wash the mop.
-
As long as the drain pipe does not leak indoors, it will not affect health.
-
There is no impact. The drain pipe is used to send condensate when cooling in the summer, and it will not drain in the winter.
-
Placing the air conditioner drain indoors will not affect the health, but only the aesthetics of the room.
-
Does it affect the health of an air conditioner drain indoors? The water in the air conditioner drain is just. Condensate has no effect at all and does not affect any health at all.
-
The air conditioner drain pipe is higher than the air conditioner definitely has an effect:
1. If the indoor unit is equipped with a condensate lifting pump, the condensate drainage pipe can be higher than the indoor unit, but there should be a ranking slope, preferably between 1/1000 and 5/1000.
2. If the indoor unit does not have a water pump, the drainage pipe shall not be higher than the indoor unit, otherwise the drainage room will not be able to drain the water, and the condensate will flow out from the lowest point of the indoor unit.
3. If it is a wind-cooled air machine, the drain pipe should also be blocked to prevent condensate from blowing out of the tuyere.
4. When the condensate pipe is long, make a ventilation hole every 2-3 meters to prevent holding air and the water cannot flow out.
-
There must be an impact, when the air conditioner is cooling, the condenser of the internal unit will have water droplets in the drainage groove, and the water will flow to a low place through gravity, and it will be discharged from the drainage pipe. If the drain pipe is higher than the inner unit or higher than the internal machine drain tank, the water will accumulate and flow out of the internal unit.
-
Cabinet air conditioner The height of the water outlet hole.
No problem, the cabinet outlet is 25cm down from the top of the air inlet baffle. No problem at all. The most severe water pipes have a small U-shape.
Is it okay for the middle section of the air conditioner outlet pipe to be higher than the water outlet?
No, this will cause the indoor unit to leak and the drain pipe should not be higher than the indoor unit sink under any circumstances. Intuition is not higher than the lower part of the machine.
The outdoor unit of the air conditioner is higher than the hang-up position of the indoor unit, what will be the effect on the air conditioner itself.
It didn't work.
The installation height of the outdoor unit of the air conditioner can be higher than that of the indoor unit, but it can also be lower than that of the indoor unit, but the hole in the wall must be about 50 cm lower than the indoor unit, and the hole through the wall should be oblique below the hole (high inside and low outside).
This ensures the proper discharge of condensate and ensures that outdoor rainwater does not flow into the room on rainy days. When the outdoor unit is higher than the indoor unit, the drain pipe must be isolated from the refrigeration pipe to ensure the normal discharge of condensate. When the outdoor unit is lower than the indoor unit, the drain pipe can be tied with the refrigeration pipe.
This is also a common installation method. 1. The air conditioner should be installed on the balcony, floating plate or under the window to reserve a position, which is convenient for installation and maintenance, and the air conditioner should be firm according to the installation surface and have sufficient load-bearing capacity, and at the same time, the machine should be placed smoothly to avoid instability caused by vibration and increase potential safety hazards.
2. When the air conditioner is installed outdoors, try to avoid places with strong wind, direct sunlight or high temperature, otherwise it will affect the cooling and heating effect of the air conditioner. There should be a space of not less than 20cm on the side and back of the air conditioner to facilitate air circulation and strengthen the heat dissipation of the air conditioner. If the distance from the wall is too close, it will affect the heat dissipation of the air conditioner, resulting in the air conditioner not working properly.
There must be an effect, there will be water dripping in the condenser of the air conditioner and chiller, which will flow down from the drain pipe through the gravity principle of water. If the drain pipe is higher than the machine or above the machine drain tank, the accumulated water will flow out of the machine.
-
1. The sewage flowing out of the drainage pipe of the washing machine is directly discharged to the outside to cause damage to the community environment, and evaporate into the air to affect everyone's health;
Second, the washing machine drainage pipe is connected to the air conditioning drip pipe, which is equivalent to making the sewage directly connected with the air of your own home, which will cause indoor odor in the short term, and the long-term connection will cause direct harm to the health of indoor personnel;
3. Air conditioners belong to household appliances, which have a fixed drainage system when used, and they are condensate, and this water is clean. The drainage of the washing machine is sewage, and it must be discharged when the air conditioner is not in use, which will cause harm to the air conditioner itself, shorten the service life, and increase the probability of failure.
-
Hello dear [happy to accompany dig], will it affect when the air conditioning drain pipe is higher than the indoor air conditioner? It's not that it has an impact, but the condensate of the indoor unit can't flow out at all, and finally it all flows to the room. There must be an impact, when the air conditioner is refrigerated, there will be water droplets in the condenser of the internal engine in the drainage tank, and the water will flow to a low place through the principle of gravity and water will be discharged from the drain pipe Lu Shen core.
If the drain pipe is higher than the internal machine or Gao Xiaodan is in the internal machine drainage groove, the water will accumulate and flow out of the internal machine.
-
1. The air conditioning drain pipe can be placed indoors, and there is no impact at all, and the water in the drainage pipe is the water in nature (the cooling principle of air conditioning is to change the moisture in the air from gaseous to liquid heat absorption, and the resulting water will be discharged from the drainage pipe).
2. However, the drainage pipe is easy to breed mosquitoes in summer, so it is better to put it outdoors if there are conditions.
-
What is the effect of the length of the air conditioner drain on the air conditioner? Hello dear, there is still a standard for the length of the air conditioning pipe, generally the shorter the air conditioning copper pipe, the better, theoretically the air conditioning copper pipe length of more than 15 meters after there is no refrigeration effect. In the case of no more than 15 meters, the length of the copper pipe of the air conditioner depends on the specific situation, the manufacturer standard configuration of 1-2 horses 3 meters, 3 horses 4 meters, 5 horses 5 meters, the general manufacturer said that it is 3 meters, but sometimes there are only meters, sometimes there will be meters, up and down will not deviate too much.
1. When the pipeline exceeds 15 meters from Li Zhen, the refrigeration effect of the air conditioning connecting pipe will be greatly reduced, and the bright disturbance will hardly even have the desired refrigeration effect. In severe cases, it can also cause the body to be overloaded and even severely damaged. 2. In the actual design and construction, if the copper pipe of the air conditioner exceeds 15 meters, Jingming needs to increase the cooling capacity, and the refrigeration effect will be affected to a certain extent.
According to the manufacturing theory of air conditioner, if the air conditioning connecting pipe is too long, it is easy to produce excessive load, and it is easy to have the problem of poor oil return of the compressor, which affects the service life of the compressor. Hope it helps.
1. Wrap the insulation pipe:
Before the renovation, the drainage pipe is covered with insulation pipes (there are various specifications on the market, thick foam pipes), and then the hanging shed and decorative pipes. >>>More
Put a sealed trap on the outlet pipe, then install a bottom hole at the bottom of the outdoor unit, and then connect a small pipe to the outlet pipe as needed. Once the pipes are connected, it's time to drain the water. When installing the air conditioner drain pipe, first we need to put the sealing ring on the drain pipe, and then install the outdoor unit in the ventilated place, and rotate the outdoor unit drain pipe about 90 degrees. >>>More
1.longitudinal and transverse drainage and permeability of highways; 2.Vertical and horizontal drainage of the back of various retaining walls and side ditches of highways; 3. >>>More
UPVC, flexible cast iron pipe, PE double wall corrugated pipe, etc. are used for drainage pipes. >>>More
First, the water pipe in the machine is damaged. Second, the installation of the indoor unit is unqualified, and the pipe outlet is too high.