-
Electric kettle common fault maintenance methods:
1. The light is on but the water temperature does not rise significantly.
This is one of the most common faults in life, it is generally caused by the damage of the thermostat switch, in the maintenance to buy the same type of thermostat switch first, and then use a tool to disassemble the kettle, and then remove the damaged thermostat switch, replace it with a new one, and finally add water to electrify to see if the fault is eliminated.
2. The water is not kept warm after boiling.
The above failure is caused by the thermostat switch is loose or closed, at this time, the thermostat switch should be checked first, if there is a problem, you should buy the same model of switch to replace. If the switch is not damaged, but is loose, simply re-tighten the loose switch. Note that the switch should not be damaged during maintenance to avoid the kettle being scrapped if the same type of switch cannot be found.
3. Poor contact with internal power cords or sockets. Check whether the electric heating pipe is obviously fouled, and whether the contact between the base and the power plug of the pot is obviously poor. If the electric heating pipe is fouled, you can first scrape it with a knife and then sand it with sandpaper.
If the contact between the base and the power plug holder of the pot body is obviously poor, the shape can be corrected so that the two are in close contact.
4. It is mainly caused by the failure of the reset switch. Usually the problem is that the temperature sensor is obviously bent and deformed, or the action of the key switch connecting rod is blocked. For the former, the convex angle of the small tongue of the thermostat can be directly bent to make it push the key switch connecting rod normally.
For the latter, it is necessary to identify the key parts of the restriction or the foreign body, which can basically return to normal as long as we need to remove the foreign body and adjust the reduction.
-
If the heating tube is damaged, it cannot be replaced. Because the heating pipe and base of the electric kettle are formed at one time and cannot be repaired, the terminal of the heating pipe can be reconnected by virtual connection, and if the wire is broken, it can be repaired by spot welding machine welding method.
If the power plug-in is damaged, replace it directly. If the terminals on the coupler are damaged, simply replace the coupler with the original model.
It could also be that the temperature switch is broken. Check the top part of the electric kettle, unscrew the electric kettle, and observe if the wires are burned or disconnected, or measure it with a universal meter.
Related Notes:
The switch on the top of the kettle is a temperature control switch, measuring whether it is working normally, up on time is open, down on time is off.
If it doesn't work properly, it's okay to replace one (this switch is very cheap, there is no need to repair it, and it is sold in general appliance repair stores).
Slow heating: It is most likely that the plug socket is in poor contact, the indoor power line or the power supply voltage is too low. First rule out these causes, and then check whether there is serious fouling in the electric heating pipe, whether there is poor contact between the power plug base and the base of the kettle, etc.
If it is dirt, you can scrape it with a knife and then polish it with fine sandpaper. If the contact is poor, you can first remove the contact piece and dirt of the plug holder, and the contact oxide layer, and then correct the shape to make the contact good.
If the indicator light is on, it means that the fault is in the electric heating pipe or its connecting part, and it may be that the electric heating pipe is damaged or in poor contact. You can judge by removing the electric heating pipe and measuring its resistance. Poor contact is mainly due to the corrosion or deformation of the contact reed in the power plug, which can be disassembled and cleaned up, and replaced with a new one if it is seriously damaged.
The above content reference: Encyclopedia - Electric kettle.
-
Summary. Hello, glad to answer for you. Kiss, the kettle light is not lit and the heating is the reason; 1.The split type may check the heating switch first (automatically jumps off after boiling water), because the water vapor is easy to rust the heating switch, causing the electric kettle to not be energized, and the light will not be lit.
What is the reason why the kettle light is not lit and still heated.
Hello, glad to answer for you. Kiss, the kettle light is not lit and the heating is the reason; 1.The split type may check the heating switch first (automatically jumps off after boiling water), because the water vapor is easy to rust the heating switch, causing the electric kettle to not be energized, and the light will not be lit.
2.Check whether the kettle is in good contact with the circular power socket in the center of the chassis, due to long-term use and water ingress, the socket is easy to oxidize and rust, resulting in the electric kettle cannot be powered on, and the light will not be on.
-
Summary. Hello! The reasons and solutions for the heating of the kettle lamp is not lit, 1. The main circuit is not connected, you can use the multimeter to check whether the kettle base and power cord are normal, usually the base is damp, the contact is oxidized and rusted, and the contact is not connected; 2. Check the switch assembly, mainly check whether the main power plug of the switch assembly is normal.
The switch assembly is in the handle, because it is often at high temperature, it will cause the plastic at the plug of the main power supply to melt, the contact displacement of the switch, and the power supply can not be connected, resulting in the indicator light is not lit, and the heating plate has no electricity, so it can not be heated, in this case, a switch assembly can be replaced; 3. If there is a problem with the power cord, you can replace the power cord. 4.If there is a problem with the switch, the common reason is that the temperature sensor is seriously deformed or the switch connecting rod is blocked.
For the former, the angle of the temperature sensor can be rebent so that it can push the switch connecting rod normally. For the latter, it is necessary to find the obstructed part or foreign body, which can generally be restored to normal by removing the foreign body and correcting the position. 5.
If the power switch is normal, the fault mostly occurs in the insulation switch. First of all, see whether the reed of the bimetal sheet is pressed against the switch contact rod, if it is pressed too tightly, you can use tweezers to bend it upwards until the distance between the two. If the distance between the bimetal sheet and the switch lever is normal, the switch box should be disassembled, and the contacts and reeds of the insulation switch should be cleaned and repaired.
Lights do notBright also heats.
Hello! The reasons and solutions for the heating of the kettle lamp is not lit, 1. The main circuit is not connected, you can use a multimeter to check whether the kettle base and power cord are normal, usually the base of the kettle is damp, the contact is oxidized and rusted, and the power supply is not connected; 2. Check the switch assembly, mainly check whether the main power plug of the switch assembly is normal. The switch assembly is in the handle, because it is often at high temperature, it will cause the plastic at the plug of the main power supply to melt, the contact displacement of the switch, and the power supply can not be connected, resulting in the indicator light is not lit, and the heating plate has no electricity, so it can not be heated, in this case, a switch assembly can be replaced; 3. If there is a problem with the power cord, you can replace the power cord.
4.If there is a problem with the switch, the common reason is that the temperature sensor is seriously deformed or the switch connecting rod is blocked. For the former, the angle of the temperature sensor can be bent to make the action of pushing the switch connecting rod normal.
For the latter, it is necessary to find the obstructed part or foreign body, which can generally be restored to normal by removing the foreign body and correcting the position. 5.If the power switch is normal, the fault mostly occurs in the insulation switch.
First of all, see whether the reed of the bimetal sheet is pressed against the switch contact rod, if it is pressed too tightly, you can use tweezers to bend it upwards until the distance between the two. If the distance between the bimetal sheet and the switch lever is normal, the switch box should be disassembled, and the contacts and reeds of the insulation switch should be cleaned and repaired.
6.Common electric heating pipe damage, remove the electric reverence type heat pipe to measure its resistance can be judged. The electric heating tube is damaged and can only be replaced.
7.The poor contact of the electric heating pipe is mainly due to the serious corrosion of the contact reed in the power plug assembly or the shape of the change grip, which can be disassembled and repaired by the switch box, and it is best to replace it if the damage is serious.
Hello! That's it.
Hello! The above are the reasons and solutions for the electric kettle light to not light up and still heat.
-
1. The indicator light of the electric kettle is on, indicating that the power cord is good, either the metal sheet in the base of the electric kettle is in poor contact with the electric heater, or the electric heater is damaged. 2. But generally it is a fault caused by poor internal contact, you can tear off the self-adhesive outside the indicator light, expose the screws, remove it with a driver, you can open the base panel, and then unscrew the fixing screws inside the base, remove the small screw in the middle of the disassembled base, you can see the contact surface between the metal sheet and the electric heater, the general contact with the poor metal sheet will change color, if it is normal, you can use a multimeter to measure whether the electric heater is good, if damaged, You can go to the electrical market to buy a set and reinstall it.
-
Summary. Dear, to provide you with the following answers, the reason why the kettle light is not heated on:
1. When in use, if the power switch is normal, the fault mostly occurs in the insulation switch. First of all, see whether the reed of the bimetal sheet is pressed against the switch contact rod, if it is pressed too tightly, you can use tweezers to bend it upwards until the distance between the two reaches 1mm. If the distance between the bimetal sheet and the switch contact lever is normal, the switch box and reed should be disassembled.
2. In some cases, the indicator light is on, indicating that the power supply has been added to the indicator circuit, which is also very important. The fault is in the electric heating pipe or its connecting part, and it is common for the electric heating pipe to be damaged and the contact is poor. Remove the electric heating pipe and measure its resistance value.
If the heating pipe is damaged, it can only be replaced. The poor contact is mainly due to the serious corrosion or deformation of the contact reed in the power plug assembly, and it is best to replace it with a new one if the damage is serious.
How to repair the electric kettle if the power on indicator light is not heated?
Dear, to provide you with the following answers, the reasons why the kettle light is not heated on: 1. When using, if the power switch is normal, the fault mostly occurs in the insulation switch. First of all, see whether the reed of the bimetal sheet is pressed against the switch contact rod, if it is pressed too tightly, you can use tweezers to bend it upwards until the distance between the two reaches 1mm.
If the distance between the bimetal sheet and the switch contact lever is normal, the switch box and reed should be disassembled. 2. In some cases, the indicator light is on, indicating that the power supply has been added to the indicator circuit, which is also very important. The fault is in the electric heating pipe or its connecting part, and it is common for the electric heating pipe to be damaged and the contact is poor.
Remove the electric heating pipe and measure its resistance value. If the heating pipe is damaged, it can only be replaced. The poor contact is mainly due to the serious corrosion or deformation of the contact reed in the power plug assembly, and it is best to replace it with a new one if the damage is serious.
3. When at home, the indoor power supply line or plug socket is not in good contact, and it should be eliminated first. It is also inevitable. Then check whether the electric heating pipe is seriously fouled, whether the contact between the base and the power plug holder of the pot body is seriously bad, etc.
If the electric heating pipe is fouled, you can scrape it with a knife first, and then polish it with fine sandpaper. If the contact between the base and the power plug seat of the pot body is seriously poor, the contact piece and the contact oxide layer of the plug holder can be cleared first, so that the contact between the two is close and good.
Provide a reference.
-
How to repair the electric kettle light if it is not heated, hello, Cause analysis: 1. If the indicator light of the electric kettle is on, it means that there is no problem with the power cord, but if the electric kettle is not heated, then it may be caused by poor contact between the metal sheet inside the base of the electric kettle and the electric heater of the electric kettle, and it may also be caused by the damage of the electric heater of the electric kettle. 2. Therefore, when the indicator light of the electric kettle is on but not heated, it is necessary to find the reason for not heating first, and then take appropriate maintenance methods according to the actual situation.
If the cause is different, the maintenance method will be different, I hope my answer will be helpful to you, Finally, I wish you good health and a happy mood! <>
For your problem, first of all, check whether the switch of the heating air is normal, that is, the base switch, the fan does not turn to explain, whether there is a mechanical block, or a certain element of the circuit is broken, such as thermostat, broken wire, etc., in short, to check carefully, but also to see the resistance of some heating elements, whether it is damaged, it is best to measure it with a multimeter, so that it can be more accurate, otherwise it can not be solved, I really don't understand, you can ask some professionals, but also to see whether some peripheral switches are damaged, Hope it helps, it's just a personal opinion.
Reasons why the kettle does not heat up when it is energized: >>>More
It's obvious that there is a problem with the circuit. Check whether the socket is broken, whether there is a voltage output, and check whether the live wire input relay has a voltage input on the electric control board. Otherwise, the terminal block is in poor contact, see if the line is loose, if you are a user, I suggest that it is best to find a maintenance master to come to the door.
Maybe I pressed that button. You unplug it and try again. My washing machine sometimes has to be unplugged and plugged in.
It could be that the graphics card or monitor is faulty. If you are using a discrete graphics card, you can switch to an integrated graphics card and check if the output is normal**. Change the monitor and ** cable to see if it can be displayed normally. >>>More