Spring is coming soon, summer is coming soon, air conditioning relocation equipment again and again, the following by Shenzhen Ant Moving Company to explain the tips for moving air conditioners.
When moving the air conditioner, the first thing to do is to prepare a set of refrigeration repairs and seat belts, and the others should be at least two people. The first step is refrigerant. Whether you are relocating in summer or winter, you must move the refrigerant in the air conditioner to the outdoor unit.
Start the air conditioner before dismantling, set the air conditioner to the refrigeration condition, and then use a wrench to unscrew the cap on the interface between the liquid pipe and the gas pipe of the external machine when the refrigeration condition is normal. Close the valve, close the low-pressure pipe cut-off valve after a few minutes, shut down the machine quickly, unplug the power plug, and tighten the safety cap with a wrench. At this point, the refrigerant work is over.
In order not to get troublesome after moving, you can also choose the force start button on the indoor unit to turn it on. After the refrigerant is finished, the indoor unit can be dismantled at this time. Use a wrench to unscrew the coupling lock nut of the indoor unit, and use the prepared sealing sodium to unscrew the silk pattern of the coupling joint of the indoor unit.
Shenzhen Ant Moving Company reminds you that you must connect the signal line and the power cord together, otherwise it will constitute that the external machine does not work, or the machine is not controlled. After all, it is necessary to disassemble the outdoor unit, which must be disassembled by a refrigeration maintenance worker to ensure safety. Pay attention to safety in the process of dismantling and avoid bumps.
Shenzhen Ant Moving Company tells you through many times of handling air conditioning experience: in order to avoid dust and moisture in the air from entering the air conditioner, after dismantling, the four ports of the coupling reception should be blocked. After all, it is tied with a plastic bag and trayed for easy handling.
The maximum skew angle of the air conditioner during the handling process should not exceed 45 degrees.
Lying down and handling, the refrigeration oil in the compressor will gradually flow out, which constitutes the lack of refrigeration oil in the compressor, so that the compressor will heat up seriously when it is working, on the one hand, it is easy to constitute the shrinker tripping, and the other will also affect the life of the compressor.
-
The indoor unit of the air conditioner should not be exposed to rain and water to prevent electricity leakage and collision.
Before the air conditioner is removed, the Freon should be put away to avoid causing a lack of fluoride in the air conditioner. In order to keep the nozzle clean and prevent dust from entering, it is best to seal the nozzle with adhesive tape. Note: Air conditioners are most afraid of water, dust, air).
Do not flatten the removed connecting pipes to avoid unobstructed pipes in the air-conditioning and refrigeration system. At the same time, remove the connecting pipe and make the interfaces and joints not collide, so as not to cause fluorine leakage in the air-conditioning and refrigeration system.
It is best to have an inclination of less than 45 degrees during the handling of the air conditioner, in order to prevent the compressor oil from entering the pipeline and causing high-pressure ice blockage, so the outdoor unit must be flat, not tilted or fallen. In case the tilt is more than 45 degrees, then be sure to leave it for 10 hours.
After the air conditioner is installed, remember to clean the air vapor in the air conditioner, so as not to cause the pressure in the air conditioning refrigeration system to be too high and affect the refrigeration effect.
-
<> need to pay attention to the following points when moving the buried block rough air conditioner:
1.Prepare tools: Gloves, wrenches, screwdrivers, rulers, protective pads and other tools are required to carry the air conditioner.
2.Power-off disassembly: Before moving the air conditioner, you need to remove the air conditioner, including removing the power cord, drain pipe, pipe connection, etc., and then remove the air conditioner fixing screws.
3.Protective measures: When handling the air conditioner, it is necessary to use a protective pad to wrap the air conditioner to avoid scratches or damage.
4.Sectional handling: The air conditioner is relatively heavy, and it generally takes more than two people to carry it. The air conditioner can be divided into several parts and transported separately to avoid excessive weight and injury.
5.Pay attention to safety: When handling air conditioners, you need to pay attention to safety to avoid falling or colliding, and at the same time, you should wear suitable shoes to avoid slipping or spraining.
6.Installation and commissioning: After handling the air conditioner, it is necessary to reinstall and debug the air conditioner, including reconnecting the pipes, power supply, drain pipes, etc., and debugging and using it in accordance with the air conditioner instructions.
In conclusion, handling an air conditioner requires attention to safety and protection measures to avoid damage or injury. If you are not familiar with the operation, it is best to ask professionals to move and install the shed.
When carrying heavy loads, for the safety of the lower back, the following two principles should be followed: >>>More
Inverter air conditioner is based on ordinary air conditioner, which selects a special compressor for inverter, and adds a variable frequency control system. Its basic structure and refrigeration principle are exactly the same as those of ordinary air conditioners. The host of the inverter air conditioner is automatically continuously variable speed, which can automatically provide the required amount of cold (heat) according to the room situation; When the indoor temperature reaches the desired value, the air withering host will operate at a constant speed that can accurately maintain this temperature, so as to achieve "non-stop operation", so as to ensure the stability of the ambient temperature. >>>More
Nowadays, many people have air conditioners in their homes, which can be said to be one of the common appliances in summer. Although many people use air conditioners in their homes, most people don't know how air conditioners work. Do you know the principle of air conditioning? >>>More
Is it that in a certain period of time, the lower the temperature, the greater the power consumption Answer: Yes, the lower the temperature setting, the greater the power consumption. Because the temperature setting is low, the compressor will run for a longer period of time, and the power consumption will definitely be more. >>>More
Inverter air conditioner is not good mainly because of the compressor, simply put, inverter air conditioner is to add a frequency converter to the structure of conventional air conditioning. The compressor is the heart of the air conditioner, and its speed directly affects the efficiency of the air conditioner, and the operating speed of the compressor, the heart of the air conditioner, is adjusted, so as to achieve a reasonable use of energy. When purchasing inverter air conditioners, we should start from brand awareness, reputation and the overall R&D strength of the enterprise, shop around, and then shoot when it is time to shoot.