1. It may be that the air pressure is insufficient, and before using the gas stove, you need to check carefully to see if the gas at home is sufficient, or it may be that the switch of the gas source is not turned on, so it will be affected.
2. It is also possible that there is a blockage at the nozzle or valve core. Or if the nozzle is too large, it will cause too much airflow, which will cause the gas stove to not ventilate.
3. If the above problems are still not ventilated, we can check that there is a light metal rod on the gas stove to see if the flame can burn, and then we adjust the damper to make sure that the flame can burn, so as to ensure that there is no problem. However, if it can't be burned, it means that the thermocouple has been damaged.
4. Another reason may be that the gas stove has the function of overvoltage protection, and if the pressure is too high, it cannot be started.
The above is the reason why the gas stove is not ventilated, I believe you have a certain understanding of this, I hope it can help you.
-
1.One is that the battery is low (if your Vantage is ion induction flameout protection, then it should be two No. 1 batteries, the battery is insufficient and the solenoid valve cannot work normally and cannot be ignited normally.) The battery can be replaced with a new one).
2.The other is that the solenoid valve is broken. Because Vantage uses a single solenoid valve, after the solenoid valve is broken, the electricity on both sides cannot be ignited normally.
You can replace the solenoid valve after the sale. Solution:1
Check the gas source to ensure that there is no arrears and that the gas supply is normal. 2.Check the pressure reducing valve, and if overpressure is suspected, adjust it several times in the direction of minus or counterclockwise; If the solenoid valve is damaged, it will lead to no gas output, and the solenoid valve of the same model can be replaced; If the pulse igniter is damaged, the solenoid valve will not work and will not be able to supply gas.
At this point, the pulse igniter needs to be replaced. Check the battery level. If the battery lasts for a long time, you can directly replace it with a new battery tester.
3.If a single pipeline is blocked, it is generally the burner fire hole blocked, and the thin steel wire can penetrate; Or disassemble the furnace head, hit it with metal or burn it with a welding torch flame to make all the internal impurities and foreign matter fall out.
-
1. One is that the battery is insufficient (if your Vantage is protected by ion induction, then it should be two No. 1 batteries, and the solenoid valve cannot work normally when the battery is insufficient, so it cannot be ignited normally, and it can be replaced with a new battery).
2. The other is that the solenoid valve is broken, because Vantage uses a single solenoid valve, so after the solenoid valve is broken, both sides of the electricity cannot be ignited normally, and the solenoid valve can be replaced after sale.
Solution: 1. Check the gas source to ensure that the gas source is not in arrears, and it is normal.
2. Check the pressure reducing valve, if you suspect that the overpressure can be adjusted to the minus direction or counterclockwise direction for a few turns; If the solenoid valve is damaged, it will result in no gas output, and the solenoid valve of the same type can be replaced; If the pulse igniter is damaged, the solenoid valve will not work and the gas supply will not be possible, and the pulse igniter needs to be replaced; Check the battery level, if it has been used for a long time, you can directly replace the new battery for testing.
3. If it is a single pipeline blockage, it is generally a plugging fire hole in the furnace head, which can be penetrated with a thin steel wire; Or disassemble the burner, knock it with metal or grill it with a welding torch to make the impurities and foreign matter inside the burner fall out.
-
If the gas stove is not ventilated, what is the reason for the gas stove not ventilating, first look at whether it is the cause of the pipe, whether the pipe is blocked, or whether the gas is this. The reason for the blockage of the gas pipe, in the case of the gas stove, should be that the gas belt has a blocked pipe.
-
If your gas stove is not ventilated, first check that the pressure valve is usually blocked in the pressure valve.
-
Gas stove not ventilated repair:
1. First of all, of course, check whether the gas source is enough, if the gas source is not enough, the air pressure will also be reduced, resulting in the phenomenon that the ignition is fine but cannot be ventilated, including natural gas and gas tanks.
2. Check the power circuit of the gas stove again to see if the battery at the bottom of the gas stove is out of power and needs to be replaced; There is also a circuit problem in the battery box, check it to see if there is any poor contact, mainly the contact plate of the positive and negative electrodes is rusty.
3. The gas pipeline is blocked, although this situation is rare, but it can not be ignored, the main inspection is the gas outlet valve and the filter inside, if it is blocked, it will obviously lead to poor gas outlet, and even the situation of no gas, the blockage here also includes the blockage of the jet nozzle inside the stove, which also needs to be dredged together.
4. Overvoltage protection is also one of the factors, many gas stoves on the market have this function, that is to say, when the gas pressure reaches a certain level, the high-pressure protection will be triggered, resulting in no gas coming over during ignition, and the ignition cannot be ignited.
-
How to deal with the gas stove not ventilating:
1. If the gas stove has no battery or the battery is rusty, we need to replace the battery in time.
2. If the gas path is blocked, we must dredge the gas path in time.
3. If the nozzle of the gas stove is blocked, we must dredge the nozzle in time.
4. If the parts or other components are aging, we must replace and repair them in time.
If there is no gas, if the gas stove does not catch fire, the first thing to check is whether there is still gas, and if there is none, you must add gas.
Whether the battery has electricity or not, when you find that the ignition is not on fire, you must check whether the battery has electricity, if not, you only need to replace the ordinary No. 1 battery.
Poor circuit contact, mainly to check whether the positive and negative poles of the battery box are rusty, whether the line has poor contact, if so, the rust needs to be removed, and the line is accurately connected.
Overpressure protection, many gas stoves have overpressure protection function, once the overpressure will not start, then you have to change a pressure reducing valve to try.
-
1. No matter what kind of stove, first check whether the gas supply is normal. Then check down: if it is the oldest desktop stove, piezoelectric ignition, it is not excluded that the valve core or nozzle may be blocked.
If there is no foundation for the repair of the cooktop, the overhaul of these two components may require the involvement of professionals. If it is a built-in stove with pulse ignition and flame-out protection, first check whether the battery is charged, or replace the battery directly and try again. If the battery is ruled out, the spool and nozzle still have to be considered.
2. Open the switch knob to see if the gas is out, the flame-out protection device is broken, there is no gas discharge, and the air valve is blocked, and there are many reasons for the blockage, which should be professionally repaired and solved. In addition, look at He He to see if the pressure reducing valve (rear booster valve) has been moved. Check the thermocouple (the pointed metal rod on the stove) to see if the flame can burn, adjust the lower damper to make sure that the flame can burn, and if it can burn and extinguish, the thermocouple is broken.
-
When the gas stove is not ventilated is mainly caused by a number of reasons, if the battery inside is out of power or aging, then replace it with a new one in time, if the solenoid valve fails, resulting in the magnet is not **, which will also affect the normal operation of the gas stove, at this time it is advisable to find after-sales treatment solutions.
The gas stove is a more common household appliance, if the gas stove is not ventilated when it does not ignite, it is necessary to consider whether the battery inside is aging or caused by no electricity, so that it can not lead to the normal operation of the gas stove, at this time, it is necessary to replace a new battery in time to ensure that the solenoid valve can be pushed normally.
It may also be that the solenoid valve inside is faulty, resulting in a magnetization reaction with the steel inside, so it can't catch fire, or there is a problem with the water-gas linkage valve inside that causes the air hole to be blocked, so the gas can't be lifted, and it can't catch fire.
At the same time, the gas stove itself will come with a gas leakage protection system, mainly when the gas solenoid valve is opened, when it is not in use, it will be closed.
Dreaming of a fire is a good thing and indicates that you are going to get rich.
I finally figured out how to adjust the damper of the gas stove! It took 2 days to get it done! It's actually quite simple! I started reading a lot on the Internet, but I didn't understand it! The reason is that there is no picture, it is really hard to say, let me try! >>>More
1. Improper orientation of the incineration needle will cause the separation between the incineration needle and the fire cover of the gas stove to exceed the required interval, and the interval exceeding the standard will cause the gas stove to turn off automatically. >>>More
No problem, no fear!
Generally, when we use gas, we have to turn off the gas tank first, and then turn off the gas stove after the gas stove is turned off. This burns the gas in the gas pipes. >>>More
Turn off the gas main valve and turn off the gas switch on the gas stove, remove the gas stove, this is not a gas leak, because your main gate has been turned off, and then the switch of your gas stove is also turned off, so there is no gas leakage problem.